128-7853
13 of 16
13
Setting Up The System Programming Features:
Bank 1 Transmitter Channels
Start with the system disarmed, tun the ignition switch to the on position then:
1) Press and release the push button valet/program switch 3 times.
Siren Chirps once and or Lights flash one time indicating the transmitter program mode
successfully entered.
See Owners Manual for transmitter programming.
Turn the ignition switch off then on to access Bank 2 Keyless/Alarm feature selections.
1 short/1 long chirp when the key transitions off, followed by 1 short/1 long chirp when the
key is turned on indicates that you are in feature selection of bank 2.
Press the push-button switch:
1 time to access the first selection as shown below. Use the lock button of the transmitter to
change the feature selection or press the push-button to advance to the next selectable
feature.
Bank 2
Feature
1 Chirp/Flash 2 Chirp/Flash 3 Chirp/Flash 4 Chirp/Flash
5 Chirp/Flash 6 Chirps/Flash
Default
1
st
Door L/UL
1 Sec.
3.5 Sec.
1 S.L, Dbl.U/L Dbl L, 1 S. UL
Dbl L, Dbl UL 1S L/350ms UL
1 Sec.
2
nd
Accy Lock
On
Off
Off
3
rd
Accy Unlock All Doors
Off
Off
4
th
Passive Locks
Passive
Active
Active
5
th
Passive/Active Arm Passive
Active
Active
6
th
Siren/Horn
Both
Siren
Horn
Both
7
th
Horn Chirp 10ms
16ms
30ms 40ms
50ms
16ms
8
th
Override Method Custom Code
Valet
Valet
9
th
Chp Del From TX On
Off
Off
When finished setting the keyless/alarm selectable features, turn the ignition off then on to
advance to Bank 3, Remote Start Selectable Features.
No reaction when the key transitions off and 2 long Chirp when the key transitions on.
Press the push-button switch one time to access the first selection as shown below. Use the
lock button of the transmitter to change the feature selection or press the push-button to
advance to the next selectable feature.
Bank 3
Feature
1 Chirp/Flash
2 Chirp/Flash
3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash
Default
1 RF Start Chirp
Off
On
On
2 Run Time
5 Min.
10 Min.
15Min. 20 Min.
10 Min
3 Park Lights
On Steady
Flash
Steady
4 Input Check
Voltage
Tach
Tach
5 Voltage Level
> 0.5V B4 Start < 0.5V B4 Start
> 0.5
6 Ign. 2 Select
Off With Crank
On With Crank
Same As Accy
On With Crank
7 Diagnostics
Off
On
Off
8 Crank Time
0.8Sec
1.0 Sec
1.5 Sec 2.0 Sec
1.0
9 Gas/Diesel
Gas
Diesel 10
Diesel 15 Diesel 20
Gas
10 Crank Averaging
Averaging
Preset Time
Averaging
11 RS Shock
Shunt Til Clear
Shunt RS Cycle Shunt From Tx
Shunt Til Clear
12 Turbo Select
Off
3 Mins
5 Mins 10 Mins
Off
13 Blk/Blue Aux O/P
Single Pulse
As D/L Pulse
Single
14 Time Start
2 Hours
4 Hours
4 Hours
Summary of Contents for APS-920