background image

128-9302

 24 of 28

24

SELECT

ABLE FEA

TURES

The selectable features of this unit can be set manually as explained above, or online by using our web link. 

The 

Accessory VE-PROG kit will include the nec

-

essary cables to connect to your computer along with the web access information and application required to take advantage of this feature.  Factory default settings are indicated by 

BOLD

 text below

NOTE:

 The method of manual 

override 

can either be selected to operate

 from the valet switch or operate by custom code.  Custom Code program

ming is found 

in the owners guide.  Be certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.

NOTE: 

Manual programming Keyless Entry Models with no horn output will Flash the Parking Lights instead of chirp where chirp is indicated.

Also, No data will be indicated if a feature is not available for a particular model.  

The unit will enter the feature but no selection will be available.

RF Programmable Feature Bank 1 Is For T

ransmitter Programming See T

ransmitter Programming Guide.

Programmable Features Bank 2 Is 

Alarm Selectable Features:

Feature Selection

 

 

1 Chirp

 

 

2 Chirps

 

 

3 Chirps

 

 

4 Chirps

 

 

5 Chirps

 

 

6 Chirps

 

 

 1st DoorL/UL

  

500

 mS

 

 

3.5 Sec.

 

 

500mS L, Dbl. U/L

  

Dbl L, 500mS UL

 

Dbl L, Dbl UL

 

500mS/350mS ul

 

 2nd 

Accy Lock

 

 

Auto Lock On

 

Auto Lock Off

 

        

 3rd 

Accy

. UL

 

 

Auto UL

 Dr

Auto UL

 All

 

Auto UL

 Off

 

     

 4th Headlights

  

Not A

vailable

 

     

 5th Passive Locks

  

Not A

vailable

 

         

 6th Pass/Act 

Arm

 

 

Not A

vailable

 

        

 7th Siren/Horn

 

 

Not A

vailable

 

      

 8th Horn Chirp

 

 

10mS

  

16mS

 

 

30mS

 

 

40mS

 

 

50mS

 

    

 9th O/R Method

  

Not A

vailable

 

         

 10th 2 Step U/L

  

On

 

 

Off

 

         

 1

1th Chp Del 

Tx

 

 

On

  

Off

 

     

    

 12th 

Trigger Circuits

 

 

Not A

vailable

 

   

 13th L/UL

 Poll

 

 

Not A

vailable

 14th 

Aux Ch 5 Sel

 

 

Pulse

 

 

Push & Hold

 

10 Sec

 

 

20 Sec

 

 

Latch On/Of

Hold 3/S For O/P

 

 15th 

Aux Ch 6 Sel

 

 

Pulse

 

 

Push & Hold

 

10 Sec

 

 

20 Sec

 

 

Latch On/Of

Hold 3/S For O/P

 

 16th 

Aux Ch 7 Sel

 

 

Pulse

 

 

Push & Hold

 

10 Sec

 

 

20 Sec

 

 

Latch On/Of

Hold 3/S For O/P

 

 17th 

Trigger Delay

  

Not A

vailable

 18th Data Port Select

 

DBI Protocol

 

ADS Protocol

If Programming via PC while connected to + 12 VDC you must manually enter the programming mode as shown below

.:

Turn the ignition on Press and release valet switch 3 times

Turn ignition off then on, off then on, off then on, off then on to enter web/on-line feature selection Bank 5.

Siren chirps 5 times indicating access to feature program mode.  Launch the application on your PC.  Connect the module via the USB to DBI 

 

harness and follow program prompts.

Summary of Contents for APS-687E

Page 1: ...ort Information Page 16 6 Pin Antenna Harness Page 16 Time Start Programming Information Page 17 Diesel Engine Setting Information Page 17 DBI Port Information Page 17 Engine Monitoring Selections Vol...

Page 2: ...f air bags or damage sensitive vehicle computers and electronics For technical support go to www avxtech1 com or call 1 800 225 6074 FCC COMPLIANCE This device complies with Part 15 of the FCC rules a...

Page 3: ...arking Brake Input 8 Green Yellow Glow Plug Input 9 Gray Inhibit Neutral Start Switch 10 Green Orange Tachometer input 11 DK Blue Channel 3 Trunk Release Output 12 Green Black Channel 4 Output 13 DK B...

Page 4: ...y 6 Red Battery 2 12V 7 Yellow Starter Output 8 Red Black Ignition 3 Normally Open Contact 1 Black Chassis Ground 2 White Red Parking Light Relay Power 3 Yellow Black To Controlling Alarm s Ignition I...

Page 5: ...as it is not waterproof HOOD PIN SWITCH PART 1363699 The pin switch included in this package is intended for protecting the hood area of the vehicle In all cases the switch must be mounted to a ground...

Page 6: ...it as well as the ignition 1 and ignition 2 relays 3 GREEN Wire Ignition 2 Output Connect this wire to the ignition 2 wire from the ignition switch This wire will show 12 volts when the ignition key i...

Page 7: ...itch is turned to the start crank position only This wire will have 0 volts in all other ignition switch positions NOTE This wire must be connected to the vehicle side of the starter cut relay when us...

Page 8: ...sensor s operation until the Remote Start unit shuts off B Additional Ignition Output Some vehicle s may require more than three ignition outputs to start and keep the vehicle s engine running If thi...

Page 9: ...trol module when ever it gets 12 volts If the Brake lights switch in the vehicle switches 12 volts to the brake light circuit connect the Brown w Black trace wire to the output side of the brake switc...

Page 10: ...rough the firewall into the engine compartment and connect to the negative side of the ignition coil This Remote Start unit learns the tach rate of the vehicle and in most cases will operate properly...

Page 11: ...0mS before GWR becomes active as well as when the transmitter is used to disarm the system Typical use for this output would be to disarm a factory theft deterrent system to prevent false triggering o...

Page 12: ...s will damage the control module Connect the light blue green to terminal 86 of a 30 A automotive relay and wire the remaining relay con tacts to perform the selected function of channel 5 20 Gray w B...

Page 13: ...king lights are ground switched connect this wire to chassis ground 3 Yellow w Black trace Wire Output To Alarm Ignition Input This is the positive output that will connect to an alarm system allowing...

Page 14: ...l the drivers door unlock relay and the Red Black will be used to control the unlocking of all other doors 3 Wire Ground Switched Door Lock Circuits In this application the Red wire of the door lock h...

Page 15: ...tory Switches 12 Volts Connect to Fused 12 Volt Source If Factory switches Ground Connect To Ground 87a 87 30 86 85 Fused 12 Volt Source Factory Unlock Relay 3 Wire Positive Switched Door Locks For th...

Page 16: ...tional components which may include relays fixed resistor a door lock interface or a data module You can search the vehicle www avxtech1 com www Flash It com for vehicle specific information or contac...

Page 17: ...peration Bank 3 Feature 12 over gasoline the only change is to the ignition circuits When Diesel is selected the ignition circuits will power up 10 15 or 20 seconds before the start circuit The intent...

Page 18: ...set time or the Hybrid feature will not operate indicated by the parking lights flashing 7 times CRANK AVERAGING When Feature 14 Bank 3 is set for crank averaging the remote start unit constantly moni...

Page 19: ...off Press and Hold the pushbutton switch located on the receiver unit on 2 Turn the ignition switch on off on off on off 3 The LED begins to flash two short flashes followed by one long flashes and co...

Page 20: ...BROWN BLACK NEUTRAL SAFETY WIRE TEMPORARILY DISCONNECTED IN STEP 3 MECHANICAL NEUTRAL SAFETY SWITCH CONSIDERATIONS Mechanical neutral safety switch configurations differ slightly in that they do not...

Page 21: ...ETHOD 1 87a 87 30 85 86 To Fused 12 Volt Battery Source Ignition Key In Sense Wire Closes With Key In Cylinder 1N4002 Diode 1N4002 Diode Connect To Negative Remote Start Safety Shut Down Wire Drivers...

Page 22: ...ed for an alarm trigger input be certain to use the dual diode set up shown earlier in this manual AFTER THE CONNECTION OF THE NEUTRAL START SAFETY WIRE AS INDICATED IN ANY OF THE PREVIOUS ALTERNATE C...

Page 23: ...rps Once 3 Turn the ignition key off then on you will hear 2 chirps 4 Press the pushbutton switch once to advance to feature 1 twice to advance to feature 2 etc then use the lock button of the transmi...

Page 24: ...eatures Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps 5 Chirps 6 Chirps 1st DoorL UL 500 mS 3 5 Sec 500mS L Dbl U L Dbl L 500mS UL Dbl L Dbl UL 500mS 350mS ul 2nd Accy Lock Auto Lock On Auto Lo...