background image

COMPLETING THE INSTALLATION:

ANTENNA WIRE:

 

Be sure to extend the thin black antenna wire to its full length, and cable tie into place where it cannot

be damaged. Avoid wrapping this wire around major, high current wire looms.

WIRE DRESSING:

 

Always wrap the alarm wires in convoluted tubing, or with a spiral wrap of electrical tape. Secure

these looms along the routing using cable ties.
This will ensure that the alarm wires are not damaged by falling onto hot or sharp moving surfaces in the vehicle.

OPERATION: 

Take a few moments to check off the appropriate option boxes in the owner’s manual, and to fully explain

the operation of the system to your customer.

128-4862A

Page 4

5 0f  22

ORANGE WIRE: 

 GROUND OUTPUT WHEN ARMED

This wire is provided to control the starter cut relay. Connect the orange wire to terminal 86 of the relay , and wire the
remaining relay contacts as shown in the wiring diagram.

IMPORTANT: Audiovox does not recommend using this relay to interrupt the ignition wire. Only connect this relay
to the low current starter solenoid feed wire, as indicated on the wiring diagram.

WHITE WIRE: 

+ 12 VDC PULSED PARKING LIGHT OUTPUT ( 15 A MAX )

This wire is provided to flash the vehicle’s parking lights.
Connect the white wire to the positive side of one of the vehicle’s parking lights.

DARK BLUE WIRE: 

300 mA PULSED OUTPUT/CHANNEL 2

The dark blue wire pulses to ground via an independent RF channel from the keychain transmitter.  This is a transistorized,
low current output, and should only be used to drive an external relay coil.

WARNING: Connecting the dark blue wire to the high current switched output of trunk release circuits, or some
remote starter trigger inputs, will damage the control module.

Connect the dark blue wire to terminal 86 of the AS-9256 relay (or equivalent 30 A automotive relay), and wire the
remaining relay contacts to perform the selected function of channel 2.

GREY & BLACK 2 PIN (blue) CONNECTOR:

 VALET SWITCH

Route the two conductor, blue connector from the valet switch to the alarm control module, and plug it into the mating
blue connector on the end of the module.

RED & BLUE WIRES: 

DASH MOUNTED L.E.D.

Route the two conductor, white connector (red and blue wires) from the L.E.D. to the alarm control module, and plug it
into the mating white connector on the end of the module.

RED & GREEN 2 PIN (white) CONNECTOR: 

DOOR LOCK OUTPUTS

These wires will provide a pulsed ground output to the factory door lock control relay.
The maximum current draw through these outputs must not exceed 300 mA.

3 WIRE GROUND SWITCHED DOOR LOCKS

In this application, the 

red wire 

provides a ground pulse during arming, or the 

pulsed ground lock 

output.  Connect the

red wire to the wire that provides a low current ground signal from the factory door lock switch to the factory door lock
control relay.
The 

green wire 

provides a ground pulse during disarming, or the 

pulsed ground unlock 

output.  Connect the green wire

to the wire that provides a low current ground signal from the factory door unlock switch to the factory door lock control
relay.

3 WIRE POSITIVE SWITCHED DOOR LOCKS
4 WIRE POLARITY REVERSAL and
5 WIRE ALTERNATING 12 VOLT
DOOR LOCK CONTROL CIRCUITS

In these applications, the AS 9159 Door Lock Interface (or equivalent 30 A automotive relays) must be used.
Refer to the AUDIOVOX Door Lock Wiring Supplement, for proper connection to these types of circuits.

Summary of Contents for APS-25-CL

Page 1: ...tallation 4 WiringDiagram 5 WiringReference 6 Notes 7 TABLE DES MATIERES Préparationàl installation 8 MontagedesComposants 9 CâblageduSystème 10 11 Finitiondel installation 11 Câblage 12 ChaînePorte clefs 13 Remarque 14 INDICE Preinstalación 15 Instalacióndecomponentes 16 Cableadodelsistema 17 18 Terminacióndelainstalación 18 Cableado 19 Referencia 20 Notas 21 10f 22 Model APS 25 CL Released 7 12 ...

Page 2: ...arm the system using the keychain transmitter When the optional door lock interface is installed the doors will operate according to the position of dip switch number 2 This system is shipped in the passive mode therefore no modifications are required to make the system operate as a Passive alarm As an Active alarm the system can only be armed using the keychain transmitter There will be no backup...

Page 3: ... few extra moments on each installation to fill in the chart can save you valuable time in the future TRANSMITTER PROGRAMMING The transmitters included in this kit have been programmed at the factory for the Channel 1 arm disarm and panic function only Any additional functions of the system receiver Channels 2 and 3 must be programmed at the time of installation These functions can be assigned to ...

Page 4: ...HITE w BLACK TRACE WIRE POSITIVE OUTPUT TO SIREN Route this wire through a rubber grommet in the firewall and to the siren location Connect the white black wire to the positive wire of the siren Secure the black ground wire of the siren to chassis ground BROWN WIRE DOOR TRIGGER If the vehicle s door courtesy light switches have a ground output when the door is opened GM and most Imports you must c...

Page 5: ...ent switched output of trunk release circuits or some remote starter trigger inputs will damage the control module Connect the dark blue wire to terminal 86 of the AS 9256 relay or equivalent 30 A automotive relay and wire the remaining relay contacts to perform the selected function of channel 2 GREY BLACK 2 PIN blue CONNECTOR VALET SWITCH Route the two conductor blue connector from the valet swi...

Page 6: ...Page 5 128 4862A 6 0f 22 ...

Page 7: ...WIRE COLOR VEHICLE WIRE COLOR LOCATION RED BLACK YELLOW BROWN PURPLE OPTIONAL DOOR LOCK WIRING WHITE UNLOCK LOCK CONTROL MODULE LOCATION L E D LOCATION VALET SWITCH LOCATION 128 4862A SIREN LOCATION Page 6 7 0f 22 TYPE OF DOOR LOCK CIRCUIT ...

Page 8: ...ADDITIONAL NOTES AND SKETCHES NOTES 128 4862A Page 7 Printed in U S A Audiovox Corp 150 Marcus Blvd Hauppauge N Y 11788 Form No 128 4862A 8 0f 22 ...

Page 9: ...e porte clés Lorsque l interface de verrouillage de porte en option est installée les portes fonctionnent suivant la position du commutateur DIP 2 À la livraison ce système est en mode passif par conséquent aucune modification n est nécessaire pour que le système fonctionne en alarme Passive En mode alarme active on ne peut armer le système qu en utilisant l émetteur de la chaîne porte clés Il n e...

Page 10: ...directement en perçant un trou de fixation de 7 14 mm 9 32 po Ne pas oublier que s il est correctement monté le plongeur doit s enfoncer d au moins 6 35 mm 1 4 po une fois le capot ou le coffre fermés CANAL 3 ÉMETTEUR SEULEMENT Les émetteurs de cet antivol comprennent un troisième canal indépendant de fréquence radio supplémentaire Même si le module d alarme ne répond qu à 2 canaux la troisième fr...

Page 11: ...s d entrée Mettre le commutateur DIP 4 du véhicule en position arrêt OFF Brancher le fil rouge sur une source de tension constante 12 Vcc FIL JAUNE ALIMENTATION D ALLUMAGE 12 VCC Brancher ce fil sur une source alimentée lorsque la clé et en position marche ON lancement et accessoires et non alimentée lorsque la clé est en position arrêt OFF FIL VERT FONCÉ DE DÉCLENCHEMENT INSTANTANÉ C est un fil à...

Page 12: ...émité du module et le brancher sur le connecteur correspondant à l extrémité du module CONNECTEURROUGEETVERTÀ2BROCHES BRANCHES SORTIESVERROUILLAGEDEPORTES Ces fils founissent soit une sortie masse à impulsions au relais de commande de verrouillage de porte livré d usine Le courant maximum consommé par ces sorties ne doit pas dépasser 300 mA VERROUILLAGE DE PORTE À 3 FILS PAR IMPULSION DE MASSE Dan...

Page 13: ...Page 12 128 4862A 13 0f 22 ...

Page 14: ...LANC POURPRE NIOR FIL DE VERROUILLAGE DE PORTE EN OPTION FIL DE VERROUILLAGE DE PORTE EN OPTION EMPLACEMENT DES VOYANTS DEL EMPLACEMENT DU MODULE DE COMMANDE 128 4862A MODÈLE ANNÉE TYPE DE VÉHICULE FIL 14 0f 22 EMPLACEMENT DE L INTERRUPTEUR VALET EMPLACEMENT DE LA SIRENE Page 13 ...

Page 15: ...REMARQUE ET CROQUIS 128 4862A Page 14 Printed in U S A Audiovox Corp 150 Marcus Blvd Hauppauge N Y 11788 Form No 128 4862A 15 0f 22 ...

Page 16: ...avero Cuando se instla la interfase opcional para cerradura de puertas las puertas funcionarán de acuerdo a la posición del conmutador inmerso 2 El sistema se envía en el modo pasivo y por ello no se requiere ninguna modificación para que el sistema funcione como una alarma pasiva Como alarma activa sólo se puede activar el sistema usando el transmisor de llavero En este caso no habrá activación a...

Page 17: ... empaques de caucho cuando el capó y la tapa del baúl estén cerrados Lo conmutadore de clavija pueden instalarse usando lo soporte incluido o montarse directamente perforando un agujero de 9 32 de pulgada de diámetro Tenga en mente que cuando están bien instalados el percutor debe presionarse 1 4 de pulgada por lo menos cuando la tapa del baúl o el capó están cerrados SALIDAS DE CIERRE APERTURA DE...

Page 18: ...las posiciones ON arranque y de accesorios y no esté activa cuando la llave está en la posición OFF CABLE VERDE OSCURO DE DISPARO INSTANTÁNEO Este es un cable a tierra de disparo instantáneo Debe conectarse a los conmutadores de clavija del capó y baúl previamente instalados CABLE NEGRO TIERRA DEL CHASIS Conecte este cable a una parte de metal sólido en el chasis del vehículo No confunda este cabl...

Page 19: ...ASROJOYVERDE SALIDASDECERRADURADEPUERTAS Estos cables proporcionan ya sea una salida a tierra pulsada para el relé de control de cerraduras de puertas instalado en fábrica El máximo flujo de corriente a través de estas salidas no debe exceder de 300 mA CERRADURA DE PUERTAS CONMUTADA DE TRES CABLES En esta aplicación el cable rojo proporciona un impulso a tierra durante la activación o la salida pu...

Page 20: ...Page 19 128 4862A 20 0f 22 ...

Page 21: ...EHÍCULO LOCALODAD CAVLEADO DE LA CERRADURA DE PUERTA OPCIONAL TIPO DE CIRCUITO DE CERRADURA DE PUERTA UBICACION DEL L E D UBICACION DEL MODULO DE CONTROL UBICACION DEL INTERRUPTOR DERIVANTE DE EMERGENCIA UBICACION DE LA SIRENA 128 4862A ROJO NEGRO PARDO PURPURADO BLANCO Page 20 21 0f 22 ...

Page 22: ...NOTAS Printed in U S A Audiovox Corp 150 Marcus Blvd Hauppauge N Y 11788 Form No 128 4862A 128 4862A 22 0f 22 ...