background image

CONTROLS & CONNECTIO NS  

20

 

 

 

 

2 . 7   P O W E R   S U P P L Y  

The Power Supply for your DEQ 624 has been Factory Configured to use the voltage of the electrical 
current for the country of retail sale (USA = 115V).  

WARNING: Attempting to operate this unit at 

voltages for which this power supply was not designed will void the manufacturer’s warranty and 
may result in damage to the unit and injury or even death to the operator.   

 

Summary of Contents for DEQ 624

Page 1: ...DEQ 624 DigitalStereoGraphicEqualizer PlusDynamicsProcessing User s Manual...

Page 2: ...DEQ 624 D I G I T A L S T E R E O E Q U A L I Z E R P L U S D Y N A M I C S P R O C E S S O R USERSMANUAL Version1 0 2001 PreSonus Audio Electronics Incorporated All rights reserved...

Page 3: ......

Page 4: ...reserves the right to change or improve the design of the product at any time without prior notice This warranty does not cover claims for damage due to abuse neglect alteration or attempted repair by...

Page 5: ...eSonus factory in the U S in the original packaging or a replacement supplied by PreSonus with all transportation cost and full insurance paid each way by the purchaser or owner All remedies and the m...

Page 6: ...namics Master Controls 9 Meters 9 Filters 10 Expander 11 Limiter 11 Gain 12 Bypass 12 Range 12 HI Q 13 Enabling Disabling HI Q 14 Channel A Master 15 AHC 16 Presets 16 Storing Recalling Presets 17 Sec...

Page 7: ...ue your suggestions and your comments PreSonus Audio Electronics is committed to constant product improvement The best way for us to be successful in this endeavor is by listening to the experts on ou...

Page 8: ...I Q alters the characteristics of the equalization of the DEQ 624 The center frequency remains fixed for both Normal Q and HI Q however in HI Q the effect on adjacent frequencies is less pronounced No...

Page 9: ...tentional alteration of the unit s controls will have no effect on the Preset governing the signal being processed Entering a user created three switch code combination restores complete operation of...

Page 10: ...f the DEQ 624 occupies the right side of the front panel and contains the Limiter Expander Filters Gain control HI Q switch Range switch Bypass Channel Master A AHC Program LED s Preset switch Store S...

Page 11: ...meters contained in the Dynamics Master section These meters display the output of channels A and B respectively from 42dBu to 22dBu A peak hold function has been incorporated into the output meters...

Page 12: ...ariable from 10Hz to 410 Hz The High Pass filter is always active Signals above the user selected frequency point go through i e pass unaffected The variable filter control can be rotated fully counte...

Page 13: ...nsion to begin and by selecting a ratio which controls the amount of downward expansion T H R E S H O L D The Expander Threshold control is variable from dB to Off R A T I O The Ratio control is varia...

Page 14: ...ntinues to monitor processor activity in Bypass mode Range Each channel has a Range switch for selecting the range of control for the graphic equalizer section s digital EQ encoders One of three LED s...

Page 15: ...the Dynamics Master Control section This enables HI Q select deselect mode for Channel A and disables Channel B HI Q switch and the Preset switch Any HI Q Active LED s below any of the Channel A equa...

Page 16: ...and the Store Security switch light goes OFF The 1 kHz EQ encoder is now in HI Q 4 Pressing the Channel A HI Q switch turns off both the HI Q switch light and the HI Q Active LED indicator beneath th...

Page 17: ...ay be de activated by A Pressing the Store Security switch B Turning the HI Q mode off by pressing the HI Q switch 3 The HI Q non volatile memory is updated when the HI Q mode is switched OFF R E M E...

Page 18: ...and AHC become ineffective in controlling the noise hum it is then necessary to turn AHC OFF for a few seconds so it can adapt to the new noise level and then be selected again by pressing the switch...

Page 19: ...system set up you ve just completed is now stored in the Program 1 position and can be recalled by pressing Preset until the Program 1 LED comes ON Four separate set ups can be stored and recalled in...

Page 20: ...itches Any combination of three switches while holding the Store Security switch locks the front panel U N L O C K I N G T H E D E Q 6 2 4 To unlock the DEQ 624 hold down the Store Security switch and...

Page 21: ...r 12 24 dB Green RANGE LED Indicators per channel 31 HI Q Active LED indicators 2 4 B A C K P A N E L B A S I C L A Y O U T Both channels of the DEQ 624 XLR inputs and outputs TRS inputs and outputs a...

Page 22: ...figured to use the voltage of the electrical current for the country of retail sale USA 115V WARNING Attempting to operate this unit at voltages for which this power supply was not designed will void...

Page 23: ...arrier Strip Output Output Impedance 51 Output Connectors XLR 1 4 TRS Barrier Strip Metering Level Meters 20 Segment LED 42dBu to 22 dBu Gain reduction 10 Segment LED 0 5dB to 12 dB Power Supply Type...

Page 24: ...CONTROLS CONNECTIO NS 22...