ALIGNMENT RECEIVER
1 - Alignment procedure (13,2V/26,4V;configuration”EU”)
STEP
CONDITION
ADJUSTMENT
REMARKS OF ADJUSTMENT
1
AM(EU)
Channel 20
Middle volume
level.
No squelch active
Connect HF generator to jack antenna
adjusted at ( –107dBm 1KHz 60%),
connect sinad meter to jack EXT speaker
and check that the sensitivity
(
20dB sinad).
2
FM(EU)
Channel 20
Middle volume
level
No squelch active
L 12
(For
HARRY III ASC
Only)
Connect HF generator to jack antenna
adjusted at ( –107dBm 1KHz 1,2KHz
Dev), connect sinad meter to jack EXT
speaker and adjust L12 for maximum
sensitivity(
20dB sinad).
3
AM(EU)
Channel 20
Middle volume
level
No squelch active
Connect HF generator to jack antenna
adjusted at ( –67dBm 1KHz 60%) and
check that the “S meter” displays S9.
4
AM(EU)
Channel 20
Middle volume
level
Squelch maximum
clockwise
RT1(SQ)
Connect HF generator to jack antenna
adjusted at ( –47dBm 1KHz 60%) and
adjust RT1 so that the signal is audible .
5
AM(EU)
Channel 20
Middle volume
level
Squelch maximum
counterclockwise
(ASC)
RT2
Connect HF generator to jack antenna.
Connect sinad meter to jack EXT speaker,
adjust the ouput level of HF generator and
adjust RT2 so that the opening ASC sinad
is 20dB±2dB.
Summary of Contents for JOHNNY III ASC 12/24
Page 1: ...JOHNNY III HARRY III ASC 12 24 SERVICE MANUAL...
Page 8: ...ALIGNMENT VCO PLL TP 200 TP 303...
Page 16: ...ALIGNMENT TRANSMITTER...
Page 18: ...ALIGNMENT RECEIVER L 12...
Page 19: ...JOHNNY III ASC HARRY III ASC 12 24 BLOC DIAGRAM...
Page 24: ...JOHNNY III ASC HARRY III ASC 12 24 SCHEMATIC DIAGRAM...
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ...JOHNNY III ASC HARRY III ASC 12 24 COMPONENT LAYOUT...
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ...JOHNNY III ASC HARRY III ASC 12 24 COMPONENTS LIST...