Presenza QR025 654OVSN016STS Installation Manual And User'S Manual Download Page 9

 

CONGLOMKB.COM

 

Please contact [email protected] or 1-877-333-0098 for further assistance.

Pre-Installation (continued)

WIRING CONNECTION REQUIREMENTS

Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction.
OBSERVE ALL GOVERNING CODES AND ORDINANCES WARNINGS

 

- Electrical grounding is required for this range hood . Check with 

a qualified electrician if you are not sure whether the range 

hood is properly grounded .

 

- Failure to follow electrical requirements may result in a fire.

 

- A fuse in the neutral or grounding circuit could result in 

electrical shock .

 

- If the hot/cold water pipe is interrupted by plastic nonmetallic 

gaskets or other materials, DO NOT use for grounding .

 

- DO NOT GROUND TO A GAS PIPE .

IMPORTANT: It is the customer’s responsibility to contact a qualified 

electrical installer and assure that the electrical installation is adequate 

and complies with the National Electrical Code, or CSA standards, as 

well as all local codes and ordinances .

1 .  Save installation instructions for electrical inspector’s use .
2 .  If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine if the  

ground path is adequate .

3 .  DO NOT use an extension cord or adapter plug with this  

appliance .

4 .  The range hood must be connected with copper wire only .
5 .  The range hood should be connected directly to the junction (or 

circuit breaker) box through flexible, armoured or nonmetallic 

sheathed copper cable . Allow some slack in the cable so the  

appliance can be moved if servicing is ever necessary .

6 .  A UL listed or CSA approved conduit connector must be provided 

at each end of the power supply cable (at the range hood and at  

the junction box) .

7 .  When making the electrical connection, cut a 3.2 cm (1-1/4 in hole 

in the wall . A hole cut through wood must be sanded until  
smooth . A hole through metal must have a grommet .

8 .  When cutting or drilling into the wall or ceilling, do not damage  

electrical wiring and other hidden utilities .

9.  Wire size must conform to all local codes and ordinances . The 

latest edition requirements of the National Electrical Code ANSI/
NFPA 70, or the latest edition CSA Standards C22.1-94, Canadian 
Electrical Code Part 1 and C22.2 No. 0-M91.

DANGER:

 

Risk of electrical shock . This range hood must 

be properly grounded .

DANGER:

 

Turn off the power circuit breaker or the 

power switch on the junction box before installing this 
unit . Touching circuitry inside the range hood while it is 
energized will result in death or serious injury .

DANGER:

 

All electrical wiring must be properly installed, 

insulated, and grounded . Improper insulation and grounding 
will result in deadly electrical shock .

NOTE:

 

Temporarily wire the range hood to test it for proper operation. If 
the range hood does not operate correctly, do not proceed with the 
installation.

 

- Use the power supply cable to connect the range hood 

(A) directly to the junction box or circuit breaker box . 

Use a flexible, armoured, or nonmetallic sheathed 

copper cable only . Never use an extension cord or 

adapter plug .

 

- Connect a UL-listed or CSA-approved conduit 

connector to each end of the power supply cable (at 

the range hood and at the junction box) . Connect the 

three colored wires (3) from the range hood (A) to the 

corresponding wires (4) from the electrical source: 

black to black (live), white to white (neutral), and 

green/yellow to green/yellow (ground) . Use either the 

top hole (1) or the back hole (2) of the range hood 

depending on your installation type .

 

- Turn the power on, and ensure that the lights and the 

fan are operating correctly .

 

- Once you have tested the electrical connection, 

disconnect the power supply cable and wires from the 

electrical source before proceeding with the rest of the 

installation .

Summary of Contents for QR025 654OVSN016STS

Page 1: ...UNDER CABINET RANGE HOOD INSTALLATION GUIDE AND USER MANUAL Model No QR025 654OVSN016STS...

Page 2: ...ideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the l...

Page 3: ...oid burns Smother flames with a close fitting lid cookie sheet or metal tray then turn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flam...

Page 4: ...labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the responsibility...

Page 5: ...877 333 0098 for further assistance Pre Installation TOOLS MATERIALS REQUIRED NOT SUPPLIED Measuring tape Level Utility knife Pencil Tape Adjustable wrench Phillips screwdriver Flathead screwdriver Ne...

Page 6: ...ion Quantity A Range hood 1 B Charcoal filter located inside the hood 1 C Damper located on the hood 1 HARDWARE INCLUDED NOTE Parts not shown to actual size AA BB Part Description Quantity AA Long tap...

Page 7: ...the location where the range hood is to be installed is recessed attach appropriately sized wood filler strips 4 on each side using wood screws 3 Screws are provided to secure the range hood to most...

Page 8: ...nce and use no more than three 90 elbows Ensure that there is a minimum of 458 mm 18 in of straight vent between each elbow Elbow as far away from the range hood s exhaust opening as possible Cap the...

Page 9: ...ng the electrical connection cut a 3 2 cm 1 1 4 in hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet 8 When cutting or drilling into the wal...

Page 10: ...ers refer Fig 11 Be careful not to leave any debris inside the range hood A If you are venting indoors unscrew the 2 screws holding cover 5 in place and remove the cover as per Fig 12 DO NOT REMOVE AN...

Page 11: ...al venting system Turn over the range hood A and place its top on a protective surface Unhook the charcoal filter support 9 from the support hook 10 and pull the charcoal filter support up Place the c...

Page 12: ...the screw heads about 7 mm 0 28 in from the cabinet surface Lift the range hood A into position feeding the power cable and the electrical wires through the power access opening Allow some slack in th...

Page 13: ...her TURNING ON OFF THE UNIT To turn on the fan press the appropriate speed control switch Low Speed 2 Medium Speed 3 High Speed 4 to select the desired level of power Once a button is pressed the prev...

Page 14: ...ockwise and pull it out to remove it Push in the new bulb 2 and turn it clockwise Do not release the bulb until you are sure the bulb has been securely installed Then reconnect the power If new bulbs...

Page 15: ...salt solutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow any deposits to remain for long periods of time on the range hood Rinse with wa...

Page 16: ...system detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after approximately 10 min Chec...

Page 17: ...ons QR025 757 mm 29 8 in W 120 60Hz 1 6A Push Button 300 10 High 2 x Max 25W or 35W JDR 16 GU10 twist and lock base light bulb Top venting Back venting Recirculating Inside venting 458 mm 18 in D Medi...

Page 18: ...mm 27 75 in 250 mm 9 81 in 280 mm 11 in 35 mm 1 4 in 1 5 in 38 mm 80 mm 3 13 in 28 mm 1 1 in 22 mm 0 88 in D 270 6 mm 10 65 in 355 mm 14 in 5 in 127 mm 458 mm 18 in 193 5 mm 7 62 in 757 mm 29 8 in 193...

Page 19: ...Friday Identify the required part s and have the part number s ready G H J K L AA BB D E F B C A M Part Description Code Quantity A Damper QHR130 1 B Control Switch QHR106 1 C Wiring Box QHR138 1 D C...

Page 20: ...Imported by St Laurent Qu bec H4S 2C3 1 877 333 0098 customer service conglomkb com www conglomkb com Made in China Retain this manual for future use...