No
Components
Process
Remark
13
12
Evaporator assembly
1 cut liquid feeder process pipe with clamp force(at the position
of hollow arrow indicating) and let refrigerant went out.
2 dismantle evaporator assembly and capillary
assembly by welding(at the position of arrow indicating)
Discharge pipe assembly
air return assembly
16
1 open compressor electrical cover and draw out connection line
and heat protector, and then loosen compressor earthing line from bracket.
2 dismantle compressor discharge pipe and air return pipe
by welding (at the position of arrow indicating)
1)loosen three bolts fixing footing of compressor
and take out washer, and then draw out compressor.
Compressor assembly