Premium PFV84DX Use & Care Manual Download Page 6

 

■ 

All units should be plugged into a grounded and properly-sized 

electrical outlet with appropriate overcurrent protection. Please refer 

to the electrical requirement on the nameplate. 

 

NEMA plugs 

 

NEMA 5-15P                                    NEMA 5-20P               

 

If you do not have the right outlet have a certified electrician install the correct 

power source. 

 

■ 

Please make sure that your unit has its own dedicated outlet. Do not 

use an extension cord. 

After proper installation, please plug the cord and turn on the power switch. 

 

  Operation instruction of temperature controller 

Cooler model 

 

 

 

 

 
Setting the set point (desired temperature value) 

To display or set the set point, proceed as follow: 
1)  press 

SET

 for 1s, the set value will start flashing after a few moments; 

2)  increase or decrease the value using 

UP 

or 

DOWN

3)  press the 

SET

 button again to confirm the new value. 

 

Freezer model 

 

 

 

 

 

 

Setting the set point (desired temperature value) 

To display or set the set point, proceed as follow: 
4)  press the 

SET

 button for more than 1 second to display the set point; 

5)  increase or decrease the value of the set point, using the          and           

respectively,until reaching the desired value; 

Summary of Contents for PFV84DX

Page 1: ......

Page 2: ...ON OPERATION 1 Cabinet location and installation guidelines 1 Electrical 3 SAFETY WARNINGS 5 REGULAR MAINTENANCE 6 Cleaning the condenser coil 6 Cleaning the fan blade and motor 6 Cleaning the interior of unit 6 TROUBLE SHOOTING 7 ...

Page 3: ...ay malfunction if surface is uneven If the floor is not flat please use something to make sure the base of this unit in horizontal level Install the unit in an indoor well ventilated area unit performs more efficiently in a well ventilated area for best performance please maintain clearance of 10 cm on the back of the unit 30 cm on the top of the unit at least 10 cm space around the unit outdoor u...

Page 4: ...ON PROBLEMS CAUSED BY UNPROPER POSITION OF UNITS ARE NOT COVERED BY WARRANTY Shelf installation A Hook shelf clips onto clip hanger B Place shelves on shelf clips making sure all corners are seated properly C Hook the plastic frame of price tag on shelves ...

Page 5: ...r the units Adjustable feet Caster with brake The caster has a brake turn it to different side can lock or unlock the castor ELECTRICAL Please ensure that the required voltage of the compressor is being supplied at all times CAUTION Low or high voltage can detrimentally affect the refrigeration unit ...

Page 6: ...d turn on the power switch Operation instruction of temperature controller Cooler model Setting the set point desired temperature value To display or set the set point proceed as follow 1 press SET for 1s the set value will start flashing after a few moments 2 increase or decrease the value using UP or DOWN 3 press the SET button again to confirm the new value Freezer model Setting the set point d...

Page 7: ...inutes before re plugging it Failure to do so could cause damage to the compressor UNPLUG CORD To minimize shock and fire hazards please do not plug or unplug the cord with wet hands During maintenance and cleaning please unplug the unit PROPER GROUNDING REQUIRED To minimize shock and fire hazards make sure that the unit is properly grounded PROHIBITION Do not attempt to remove or repair any compo...

Page 8: ...cessary to wash the fan blades cover the fan motor to prevent moisture damage CLEANING THE INTERIOR OF UNIT When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless steel surface Wash door gaskets on a regular basis preferably weekly Simply remove door gasket from the frame of the door ...

Page 9: ...ve amount of warm product placed in cabinet Prolonged door opening or door ajar Door gasket s not sealing properly Dirty condenser coil Evaporator coil iced over Allow adequate time for product to cool down Ensure doors are closed when not in use Avoid opening doors for long periods of time Ensure gaskets are snapped in completely Remove gasket and wash with soap and water Check condition of gaske...

Page 10: ...te time for product to cool down Replace fuse or reset circuit breaker Clean the condenser coil Ensure doors are closed when not in use Avoid opening doors Evaporator coil iced over for long periods of time see above Cabinet is noisy Loose part s Tubing vibration Locate and tighten loose part s Ensure tubing is free from contact with other tubing or components ...