Page 40
For HELP, call 727.573.9611
MESSAGE MEANING
ACTION
REQUIRED
SnA
Sensor A is not working
correctly. Hot tub is shut
down.
Check the sensor "A" plug
connection to circuit board. The
problem may appear temporarily in
an overheat situation and disappear
when the heater cools. If the problem
persists, contact service.
Snb
Sensor B is not working
correctly. Hot tub is shut
down.
Check the sensor "B" plug
connection to circuit board. The
problem may appear temporarily in
an overheat situation and disappear
when the heater cools. If the problem
persists, contact service.
SnS
Sensors are out of
balance.
If this alternates with the
temperature, it may be temporary. If
the display shows only this message
(periodically blinking), the hot tub is
shut down .If the problem persists,
contact service.
HFL
A substantial difference
between sensors was
detected (possible flow
problem).
Check water level in hot tub and add
water if necessary. Be sure that
slide-valves are open. Make sure the
pump is primed and has power. If the
problem persists, contact service.
LF
Low Flow
– persistent
problem. Displays after the
fifth occurrence of the
"HFL" message within 24
hours. Heater shuts down
but other hot tub functions
run normally.
Follow action for “HFL” message.
Heating ability of the hot tub will not
reset automatically; press any button
to reset.
dr
Inadequate water, poor
flow, or air bubbles
detected in the heater. Hot
tub is shut down for 15
minutes.
Check the water level and add water
if necessary. Be sure that slide-
valves are open. Make sure the
pump is primed and has power.
Press any button to reset
(automatically reset within 15
minutes). If the problem persists,
contact service.
drY
Inadequate water detected
in heater. Displays on third
occurrence of "dr"
message. Hot tub is shut
down.
Check water level in hot tub. Add
water if necessary. Be sure that
slide-valves are open. Make sure the
pump is primed and has power.
Press any button to reset.
Pr
When the hot tub is first
activated, it goes into
Priming mode.
The Priming mode runs for up to four
minutes and then the hot tub begins
to heat and maintain the water
temperature in Standard mode.
Summary of Contents for Leisure Edge LE630
Page 18: ...Page 16 For HELP call 727 573 9611...
Page 29: ...Page 27 For HELP call 727 573 9611...
Page 43: ...Page 41 For HELP call 727 573 9611...
Page 57: ...Page 55 For HELP call 727 573 9611 LE 744 Callouts LE 744 Parts Domestic...