INSTALLATION: 

  If there is a device that creates ozone in the space such as an ionizing air cleaner, it is recommended the oxidizing unit 

not be used in this application.  Use one of our germicidal only models instead.  Homes with multiple air handlers: 

install this unit on the main level air handler and a germicidal only model on the other air handler(s).

   • Do not locate the germicidal lamp within 20” of plastic material that will be directly exposed to the UV light, 

such as wiring, return-side humidifier or certain types of air filters. Check with the filter manufacturer to see if their 

material is UV resistant. Over time, UV light may degrade plastic. 
   • Do not touch the glass portion of the lamps with bare hands because oils from the hands can cause “hot spots” 

which reduce lamp life.  Handle either by the end caps or use a soft cloth.  If you accidentally touch a lamp, wipe it 

off, using the included alcohol cleaning pad or a soft cloth dampened with rubbing alcohol.

INSTALLING THE GERMICIDAL UNIT

MOUNTING GERMICIDAL LAMP AND POWER SUPPLY (supply or return side plenum)

1. Unplug mid-cord connector by pressing the lock release (marked “PRESS” on the connector.) (see photo B)

    Remove two thumb nuts holding moisture resistant lamp socket to mounting plate and remove from the plate.
2. Using the lamp mounting plate as a template, draw the hole pattern on the air duct in a suitable location.
3. Using a 1 1/4 inch Vari Bit, make two holes side by side. Clean off excess metal between the two 

    holes with tin snips. Alternately cut a 2” hole.
4. Peel off the gasket backing from lamp mounting plate and center over hole. Secure using four

    self-tapping sheet metal screws provided.  Repeat steps 1-4 for the second lamp.
5. Find a suitable location to mount the power supply making sure supply cord to ballast will reach 120 or  

    240 volt power supply.  Mount the power supply using four self-tapping sheet metal screws provided.
6. Taking care not to touch the glass, hold the lamp by the end cap and insert fully into the base plate.
7. Insert the moisture resistant lamp socket over the plastic lamp end fitting over the mounting studs, 

    secure using the two thumb nuts. (Photo A)
8. Route cord back to the moisture resistant lamp socket and reconnect mid-cord connector. Be sure to line up 

    arrows on the connector. (Photo B)

9.  Adhere included UV Warning Label onto ductwork within six inches of UV lamp.

Photo A

Photo B

Summary of Contents for MUV7-100TR

Page 1: ...rs d brancher avant l installation ou le service 3 Ne pas regarder la lampe directement avec les yeux Si n cessaire de le faire veuillez porter les lunettes de soleil contre les rayons U V IMPORTANT S...

Page 2: ...or by pressing the lock release marked PRESS on the connector see photo B Remove two thumb nuts holding moisture resistant lamp socket to mounting plate and remove from the plate 2 Using the lamp moun...

Page 3: ...replace ballast Note Standard off the shelf lamps are not compatible with this unit Use of improper lamps will void warranty WARRANTY RETURNS All electronic components carry a lifetime warranty to th...

Page 4: ...ly power to the unit CLEANING THE OXIDATION UNIT LAMP Recommended interval 12 months 1 Disconnect power to the unit 2 Remove the two 11 32 keps nuts and remove cover Unplug the lamp connector from the...

Page 5: ...wire to L1 white wire to L2 green wire to ground Be sure power cord is secured with included strain relief connector The unit must cycle with the furnace blower Wire unit to an EAC terminal or current...

Page 6: ...oles with tin snips 3 Peel off the adhesive backing of the gasket on backside of mounting plate 4 Center mounting plate on hole 5 Use four self tapping screws provided to secure mounting plate on the...

Page 7: ...clusion or limitation of incidental or consequential damages or limitation of the duration of an implied warranty so the above limitations or exclusions may not apply to the customer This Limited Warr...

Reviews: