Performance Data Sheet
Premier Inc.
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
UV-3
GENERAL USE CONDITIONS:
1: System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe
quality. DO NOT use with water that is micro biologically unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable
cysts.
2: Operating Temperature:
Maximum 100
o
F (40.5
o
C)
Minimum 40
o
F (4.4
o
C)
3: Operating Water Pressure:
Maximum
85-psi (5.98 kg/cm
2
)
Minimum 20-psi
4: Maximum flow Rate:
0.50 gpm (1.89 lpm)
5: Rated Capacity:
600 Gallons (2,200 liters)
6: Turbidity
< 5 NTU
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Part Number
Change time Frame
Stage 1: Sediment: 5M-10
104017
6 Months or 600 gallons of water
Stage 2: Carbon block
101015
6 Months or 600 gallons of water
Stage 3: UV Bulb
170016
12 Months or 9000 Hours
This system has been tested according to NSF/ANSI Standard 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system, as specified in NSF/ANSI 53. Testing performed under standard
laboratory conditions, actual performance may vary.
Substance
Percent
Reduction
Influent Challenge
Concentration
(mg/L unless noted)
Maximum Permissible
Product Water
Concentration
CRYPTOSPORIDIUM (see Cyst)
99.99%
minimum 50,000/mL
99.95%
CYST
99.99%
minimum 50,000/mL
99.95%
LEAD pH 6.5
99%
0.15 +/- 10%
0.010
LEAD pH 8.5
99%
0.15 +/- 10%
0.010