background image

 
 
 
 
 

Owner’s Manual

 

Page 1/12

 

20210721 

Disinfection filter (FDi) 

 

Item # 339919 

Passive disinfection filter (FDi) - 

Owner’s Manual

 

 
Congratulations on your purchase of a disinfection filter (FDi) system from Premier Tech. With the disinfection filter (FDi) system, you 
have wisely chosen to protect your health as well as the environment. This manual contains information on the operation, operating 
guidelines, maintenance and warranties of the disinfection filter (FDi).  
 
The disinfection filter (FDi) coupled with an Ecoflo biofilter is a tertiary treatment system with disinfection certified under NQ 3680-910 
(Class V). The system includes a septic tank, an effluent filter, an Ecoflo biofilter and a disinfection filter (FDi). All information relative to 
the operation, operating guidelines as well as the maintenance of the septic tank, effluent filter and Ecoflo biofilter can be found in the 
Septic tank and the Ecoflo biofilter Owner’s manual. For additional information, please contact our customer service at 1-800-632-
6356 or visit our website at PT-WaterEnvironment.com. 
 

Table of content 

1.

 

Operating Principle ...................................................................................................................................................... 2

 

2.

 

Operating Guidelines ................................................................................................................................................... 4

 

2.1

 

Type of wastewater that can be treated............................................................................................................................ 4

 

2.2

 

Recommandations ........................................................................................................................................................... 4

 

2.3

 

What you must know ....................................................................................................................................................... 5

 

2.4

 

Commissioning ................................................................................................................................................................ 5

 

2.5

 

Intermittent or extended absence and winter closure ........................................................................................................ 5

 

3.

 

Disinfection filter (FDi) features ..................................................................................................................................... 6

 

4.

 

Maintenance ............................................................................................................................................................... 7

 

4.1

 

Septic tank....................................................................................................................................................................... 7

 

4.2

 

Ecoflo Biofilter .................................................................................................................................................................. 7

 

4.3

 

Passive disinfection filter (FDi) ........................................................................................................................................... 7

 

5.

 

Sampling .................................................................................................................................................................... 7

 

5.

 

What to do in case of... ............................................................................................................................................... 8

 

5.1

 

An activated alarm ........................................................................................................................................................... 8

 

5.2

 

A prolonged power failure ................................................................................................................................................ 8

 

5.3

 

Flooding ........................................................................................................................................................................... 8

 

5.4

 

Backflow .......................................................................................................................................................................... 8

 

5.5

 

Odours ............................................................................................................................................................................ 8

 

Annex 1 – Ecoflo biofilter models ....................................................................................................................................... 11

 

Annex 2 - Notice of change of property ownership .............................................................................................................. 12

 

 

 

Summary of Contents for Rewatec Ecoflo EC-2.8

Page 1: ...Owner s manual Passive disinfection filter Certified to BNQ standard NQ 3680 910 2021...

Page 2: ...ve to the operation operating guidelines as well as the maintenance of the septic tank effluent filter and Ecoflo biofilter can be found in the Septic tank and the Ecoflo biofilter Owner s manual For...

Page 3: ...buted over the inlet zone through a pump and a low pressure distribution system For watertight bottom Ecoflo biofilters without an integrated pump the effluent is distributed over the inlet zone throu...

Page 4: ...4 0 m 4 8 m 4 m 1 260 L 3 6 3 m 5 0 m 5 6 m 5 m 1 440 L 4 7 2 m 5 8 m 6 4 m 5 m 1620 L 4 s o s o 7 2 m 5 8 m 1 800 L 5 9 0 m 8 0 m 8 0 m 8 0 m 2 160 L 6 2 x 5 4 m 2 x 5 0 m 2 x 4 8 m 2 x 4 0 m 2 500 L...

Page 5: ...s tampons condoms cotton swab etc Pharmaceutical products Cleaners for pipes or pipelines Any kind of toxic substance Household cleaning products in large Comply with the following guidelines NEVER op...

Page 6: ...ilding code Premier Tech strongly recommends using a 100 mm 4 diameter pipe for the air vent Any change in the use of your building or modification to your Ecoflo biofilter or passive disinfection fil...

Page 7: ...ted by pressing the R ARMEMENT RESET button This button can also be used to test a recirculation cycle and thus check the FDi s status To do so press and hold down the button for 5 seconds Electrical...

Page 8: ...or a qualified third party as referred to in section 1x 2 of the Regulation respecting waste water disposal systems for isolated dwellings Q 2 r 22 This service includes a visual inspection and a veri...

Page 9: ...gases and odours The position of the air vent as well as other factors unrelated to the Ecoflo biofilter itself can prevent septic gases from dispersing properly and lead to odours If this happens con...

Page 10: ...plicable regulations and or with Premier Tech s specifications as described in the Owner s Manual f Any damage or problem if it is shown that the usage of the passive disinfection filter FDi was not i...

Page 11: ...y authorized representatives to carry out all necessary monitoring and inspections as required for implementation of this Warranty If the Customer and or the Customer s Successors notify Premier Tech...

Page 12: ...Owner s Manual Page 11 12 20210721 Disinfection filter FDi Item 339919 Annex 1 Ecoflo biofilter models...

Page 13: ...ereby declare that the residence serviced by a Premier Tech treatment system located at the above address changed ownership on this date If you are the PREVIOUS owner I have provided the system s Owne...

Reviews: