Premier Mounts PTM Installation Instructions Manual Download Page 12

PTM / PTM-B

Page 12 

Visit the Premier Mounts website at http://www.mounts.com

 Installation 

Instructions

Securing the Mount

Adjusting the Mount Tension

Use the M3 Allen wrench to tighten the M6 x 35mm set 

screw located in the bottom of the PTM mount.  The M6 

x 35mm set screw prevents your 

fl

 at panel from being 

accidently dislodged.

 

  Do not overtighten the set screw.

Proceed to the 

“Adjusting the Mount Tension”

 section.

Use the M3 Allen wrench to loosen the M6 x 35mm set screw at the bottom 

of the PTM mount.

Gently lift, then gently pull the PTM mount away from the wall until it 

disengages from the wall plate.

Set the 

fl

 at panel face-down on a soft, 

fl

 at surface.

Remove the two (2) M4 x 5mm Phillips screws from the bottom mounting 

points.

Loosen the two (2) M4 x 5mm Phillips screws from the top mounting points. 

Do not completely remove these screws.

Gently slide the PTM mount towards the bottom of the 

fl

 at panel and pull 

towards you until the 

fl

 at panel disengages from the keyhole slots. 

Use a socket wrench and the supplied 14mm socket to loosen or tighten 

the tension nut.

• 

Turn the tension nut clockwise to increase tension.

• 

Turn the tension nut counter- clockwise to decrease tension.

 

  Do not overtighten the tension nut.

Tension Nut

Set Screw

M3 Allen Wrench

Replace PTM mount by guiding the heads of the top two (2) M4 x 5mm Phillips screws through the keyhole slots.

Insert two (2) M4 x 5mm Phillips screws into the bottom mounting points.

Tighten all M4 x 5mm Phillips screws.

 

  Do not overtighten the M4 x 5mm Phillips screws.

Lift your PTM mount up to the wall plate.

Slide the top of the PTM mount on to the top of the wall bracket.

Pivot the bottom of the PTM mount towards the wall plate until it rests against the wall.

 

  Do not release the PTM mount until you are certain that it is resting securely on the wall plate.

Use the M3 Allen wrench to tighten the M6 x 35mm set screw located in the bottom of the PTM mount.  

 

  Do not overtighten the set screw.

Removing the Mount

Adjusting the Tension

Replacing the Mount

Summary of Contents for PTM

Page 1: ...SA USA and Canada Phone 1 800 368 9700 Fax 1 800 832 4888 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 EUROPE Swallow House Shilton Industrial Estate Shilton Coventry England CV79JY Pho...

Page 2: ...mbly procedure Personal injury and or property damage can result from dropping or mishandling the flat panel If mounting to wall studs or ceiling studs make sure that the mounting screws are anchored...

Page 3: ...efore beginning installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts 800 368 9700 PTM Tilt Pivot Mount Components Pencil Level Wood Drill Bit...

Page 4: ...at Head Screw Qty 6 M4 x 20mm Flat Head Screw Qty 6 M4 x 30mm Flat Head Screw Qty 6 M4 x 45mm Flat Head Screw Qty 6 M5 x 10mm Screw Qty 4 M5 x 16mm Screw Qty 4 M5 x 20mm Screw Qty 4 M5 x 30mm Screw Qt...

Page 5: ...ensures that your flat panel stays were you installed it Dynamic Viewing 360 rotation and 15 of tilt allow for excellent viewing of your flat panel Adjustable Tension Stays where you want it regardle...

Page 6: ...Stud Installation Step 1 Step 2 You must secure the wall plate to the wall stud with all four 4 14 x 2 wood screws Use a stud finder to determine the exact center of wall studs in the vicinity of the...

Page 7: ...e wood screws Proceed to the Mounting Hardware section The supplied 5 16 concrete wedge anchors must be used for concrete installation You will need a 5 16 concrete drill bit which is available at you...

Page 8: ...ark all four 4 mounting locations where you will be drilling holes for the concrete wedge anchors Set the wall plate to one side in a safe location Step 1 Use a power drill and 5 16 concrete drill bit...

Page 9: ...insert on the Thread Depth Indicator as shown in Figure 1 Insert the Thread Depth Indicator into the remaining thread inserts to compare and verify their depth Locate the correct diameter screw for t...

Page 10: ...ing points Proceed to the UFP 280 Adapter Plate Installation section UFP 280 Adapter Plate Installation The UFP 280 LCD Mount Adapter is used attach flat panels with 100mm X 200mm and 200mm x 200mm mo...

Page 11: ...s screws into the bottom mounting points Tighten all M4 x 5mm Phillips screws Do not overtighten the mounting hardware Proceed to the Attaching the Mount to the Wall Plate section Flat Panel without U...

Page 12: ...anel and pull towards you until the flat panel disengages from the keyhole slots Use a socket wrench and the supplied 14mm socket to loosen or tighten the tension nut Turn the tension nut clockwise to...

Page 13: ...Technical Specifications All measurements are in inches millimeters A 75mm x 75mm VESA mounting points B 100mm x 100mm VESA mounting points C 200mm x 100mm mounting points M4 x 10mm Phillips flat hea...

Page 14: ...IMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think...

Reviews: