©Premier Mounts 2009
9531-211-001-04

Summary of Contents for LPSA3747

Page 1: ...0 East Miraloma Avenue Anaheim CA 92806 USA USA and Canada Phone 800 368 9700 Fax 800 832 4888 EUROPE Swallow House Shilton Industrial Estate Shilton Coventry England CV79JY Phone 44 0 2476 614700 Fax 44 0 2476 614710 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 Premier Mounts 2009 9531 211 001 04 ...

Page 2: ...THE SURFACE MUST BE CAPABLE OF SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF THE FLAT PANEL IF NOT THE STRUCTURE MUST BE REINFORCED THE MAXIMUM WEIGHT THAT CAN BE USED WITH THIS PRODUCT IS 80LBS PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN AS OUTLINED IN THE INSTALLATION INSTRUC TIONS MUST BE ADHERED TO FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY OR EVEN DEATH SAFETY...

Page 3: ...t pilot holes Electronic Studfinder Socket Wrench Phillips Tip Screwdriver Tape Measure Hand Held Drill Wall Plate Qty 1 Hammer LPSA3747 M6 Set Screw Qty 4 LPSA3747 Hardware Congratulations on the purchase of your new Premier Mounts LPSA3747 flat panel mount This mount is shipped with all proper installation hardware and components Make sure that none of these parts are missing and or damaged befo...

Page 4: ...0mm Qty 6 M6 x 25mm Qty 6 M6 x 16mm Qty 6 M5 x 30mm Qty 6 M5 x 25mm Qty 6 M5 x 16mm Qty 6 M8 x 30mm Qty 6 M8 x 25mm Qty 6 M8 x 16mm Qty 6 If your unit requires alternative mounting hardware use commercially available hardware or contact Premier Mounts 800 368 9700 M4 x 45mm Qty 6 M6 x 45mm Qty 6 M5 x 45mm Qty 6 M8 x 45mm Qty 6 ...

Page 5: ...ed holes should be pointing up when mounting the wall plate The flat side of the wall plate will mount flush to the wall Step 1 Determine the mount s location on the wall Step 2 Use a stud finder to locate the nearest wall stud closest to your desired location Stud Electronic Studfinder Center Line Wall Plate Positioning the Wall Plate Front View Side View Mounting Holes Wall Side Level Step 4 Usi...

Page 6: ...nts at this time Step 8 Pre drill the remaining three mounting holes Step 9 Insert and tighten the remaining three 3 14 x 2 screws Do not over tighten the screws Concrete Surface Installation Concrete Bit Level Step 1 After leveling the wall plate mark all four 4 mounting hole locations Step 2 Drill four 4 pilot holes using a drill and a commercially available concrete drill bit Level the wall pla...

Page 7: ...e Step 6 Using a screwdriver insert and tighten four 4 14 x 2 screws Do not over tighten the wall anchors Screwdriver Wall Anchor Step 3 Once the holes have been drilled place the wall anchors into the hole Using a hammer gently tap into place Make sure the mounting surface area is smooth and that the wall anchors are not protruding from the wall Hammer 14 x 2 Screws ...

Page 8: ...e installation make sure to account for the appropriate spacing depth when measuring with the thread depth indicator Using the universal spacers will change the overall length of the hardware used If your selected screw is longer than the marking on the thread depth indicator do not use this screw The screw length must not bypass the marking If so select another screw size Figure 2 and 3 until you...

Page 9: ...at this time Step 2 Insert the head of the screws through the keyhole slots on the cover plate Step 3 Insert and tighten the bottom two 2 M4 x 10 Phillip screws to secure the flat panel to the mount Step 4 Use a Phillips tip screwdriver to tighten all mounting hardware Do not over tighten the mounting screws It is recommended that the flat panel rest on a soft and flat surface while the mount is a...

Page 10: ...ocking screw will prevent the mount and flat panel from being lifted off of the wall plate Failure to fully tighten the locking screw may result in possible damage to your flat panel Locking Screw M3 Allen Wrench Set Screw Allen Wrench Step 1 Once the viewing angle has been determined use the 5 32 Allen wrench to adjust the tilt pivot adjustment screw The tilt pivot adjustment screw comes pre inst...

Page 11: ...LPSA3747 the adapter plate will have to be used The adapter plate will accommodate mounting patterns of 600mm x 400mm Mount Arm Assembly Plate Assembly Plate Mounting Rods M3 Allen Wrench M6 Set Screw 4 Total These screws should remain loose until the adapter plate is attached to the display The illustration to the left shows the two placement positions for the mounting arms Either configuration i...

Page 12: ... If your flat panel uses M8 screws use the M8 mounting points Universal Washer Installation Pre install the mounting screws spacers and washers Once mounted push down to eliminate movement from the bracket Then proceed to tighten the rest of the hardware Repeat this process for the installation of the remaining mounting bracket M4 M M6 M8 5 ...

Page 13: ...ware is most appropriate for your flat panel Step 5 At this time use an M3 Allen wrench and tighten the M6 set screws that are located on the mounting arms four total Attaching the Flat Panel with the Adapter Plate Use the universal spacers to compensate for any indentations or recessed mounting points if needed Step 1 Fasten to 1 2 the depth of the screws two 2 M4 x 10mm screws to the top two mou...

Page 14: ...llation with Adapter Plate Step 1 The cover plate of the LPSA3747 must be mounted to the wall plate that is attached to the wall Step 2 The wall plate receptacle must be placed over the top of the wall plate so that the entire mount hangs on the wall plate Step 3 Use the M3 Allen wrench supplied to tighten the locking screw that is located on the bottom of the mount base This locking screw will pr...

Page 15: ...nd tighten loosen the nut to the desired tension Step 3 Replace the plastic end caps Cable Management LPSA3747 Cable Tie Cable Flat Panel Step 1 Route all cables along the LPSA3747 Step 2 Use a cable tie to attach the cable to the LPSA3747 as shown above Step 3 Cut off excess cable tie Before routing the cables and attaching the tie wraps the LPSA3747 must be fully extended away from the wall Cabl...

Page 16: ...Installation Instructions Page 16 LPSA3747 Technical Specification All measurements are in inches mm ...

Page 17: ...NCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUD ING BUT NOT LIMITED TO INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOV ING AND REPLACING DEFECTIVE PRODUCTS OR PARTS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR ...

Reviews: