Electrical Information:
Operating Voltage range 12V model:
11V – 16V (use 25A fuse)
Operating Voltage range 24V model:
22V – 32V (use 15A fuse)
Speaker requirements:
11 Ohm impedance, 100W
rms
loudspeaker.
Or 2 * 11 Ohm impedance, 100W
rms
loudspeakers
connected in parallel.
Radio rebroadcast 1 & 2 inputs
0.5V
p-p
– 10V
p-p
input range, 10K Ohm impedance
Standby current with power on
< 20mA
Standby current without power on
< 1mA
(Current consumption due to feeds on the input lines, such as the horn)
Maximum operating current:
20A
Operating temperature range:
- 30
o
C to + 65C
Maximum continuous operation:
5 hours due to limitations with speaker(s)
This could be more or less when in an audio mode such as
PA, PLAY, RADIO depending on input frequencies and
volume levels.
Fitting information:
Leave room for airflow around the siren (approx. 50mm).
Don’t place any wiring directly on the siren casing.
The siren amplifier is not waterproof, so should be fitted in a suitable location.