Fuse Chart 

All Fuses are 3AG Type 250 Volt, SLO-BLO 

 
Export 100 Volt                              Domestic Fuses:                        Export 220, 230, 240 Fuses:

 

2.5 - 50 Watt                                   2.5 - 50 Watt                                   1.6 - 50 Watt 

3.2 - 100 Watt  

 

 

  3.2 - 100 Watt 

 

 

    2.5 - 100 Watt 

 

(Tube Complement) 

 

 

 

V1- 12AX7, Input and Gain  
V2- 12AX7, Reverb Send & Return 
V3- 12AT7, Reverb Drive 
V4- 12AX7- Effects buffer & Mixing Stage 
V5- 12AX7, Phase Inverter 
V6-V7 - 6L6 (50 watt) & V8-V9 (100 watt) 
 
 
Each fine production tube is tested and matched to our exacting specifications.  External bias 
adjustment and test points are located on the chassis near the output tube sockets.  A digital 
voltmeter and small screwdriver are required for bias adjustment.  
 

BIAS ADJUSTMENT PROCEDURE: 

-Power up unit and connect proper speaker load 
-DO NOT have an instrument connected to the input during the biasing procedure! 
-Take unit off standby and allow a few seconds for the circuit to stabilize. 
-Set multi-meter to read DC Volts   
-With meter grounded to chassis and + probe inserted into test point, measure voltage. 
-Using a small flat head screwdriver, insert into Bias pot and turn slowly adjusting Bias level 
It is recommended to only use exact replacement tubes similar to what is installed at the factory. 
Be careful when deciding to install other types of 6L6, 6V6, or EL-34 based tubes. Not all have the 

Summary of Contents for Two-Rock Studio Pro 50

Page 1: ...OWNER S MANUAL...

Page 2: ...nce with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers plugs and the point where they exit from the apparatus 9 Protect the power cord from be...

Page 3: ...ts the bass response In the full counter clockwise position low frequencies are cut In addition the response of the treble and mid range controls is greatly reduced In the full clockwise position low...

Page 4: ...Level This control has a pull bright function The loop is active in the circuit even with no effects connected so the level control acts as a master volume The pull bright feature is useful when playi...

Page 5: ...utput tube sockets A digital voltmeter and small screwdriver are required for bias adjustment BIAS ADJUSTMENT PROCEDURE Power up unit and connect proper speaker load DO NOT have an instrument connecte...

Page 6: ...35watt and 50watt Factory Setting 064V 1200V to 1400V for 100watt Factory Setting 1260V 6V6 Installed in the 22watt versions only 044V to 058V Factory Setting 054V 6V6 Installed in 22watt versions wit...

Page 7: ...other questions or comments that you may have We look forward to hearing from you PHONE 1 707 584 TONE 8663 M F 9am 5pm PST FAX 1 707 584 8661 ADDRESS Two Rock 619 Martin Avenue Suite 6 Rohnert Park...

Page 8: ...This is a product of Premier Builders Guild 619 MARTIN AVENUE SUITE 6 ROHNERT PARK CA 94928 707 584 8663 www two rock com SERIAL NUMBER _____________________________...

Reviews: