MAINTENANCE 

 

Always switch off and unplug the air conditioner from the mains before 
cleaning. To maximize the efficiency of the air conditioner clean regularly. 
 

Cleaning the housing 

Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, 

petrol, detergents, chemically treated cloths, or other cleansing solutions. These could 

all damage the unit casing. 

 

Cleaning the filter 

Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the 

filters and then rinse thoroughly under running water (no hotter than 40

°

C). Dry 

thoroughly before replacing. Never operate the unit without the filters. 

 

End of season storage 

  Drain any water in the unit before completely operating the unit on ventilation only 

mode for a few hours, to thoroughly dry the inside. 

  Clean or change the filter.

 

  Unplug and store the power cord as shown.  

 

 

Replace in the original carton or cover for storage. 

 

The air conditioner does not run 

 

 

  Is the air conditioner plugged in? 

  Is there a power failure? 

  Is the ‘WATERFULL’ indicator flashing? 

  Is the room temperature below the set temperature? 

 

The machine seems to have little cooling effect 

  Is there direct sunshine? (Please close the curtains or blinds.) 

  Are too many windows or doors open? 

  Are there too many people in the room? 

  Is there something in the room producing lots of heat? 

 

The machine is not cooling 

  Is the filter dusty, contaminated? 

  Is the air intake or output blocked up? 

  Is the room temperature below your selected temperature? 

  Is the evaporator frosts? 

 

Too noisy  

  Is the machine positioned unevenly, thus creating vibration? 

  Is the floor underneath the machine uneven? 

 

The compressor doesn’t run 

  It is possible the overheat protector for the compressor is in operation.  

 

Wait for the compressor to cool down. 

 

* Never try to repair or dismantle the unit yourself 

 

Problem Probable 

Causes 

Solutions 

“E0” Displayed 
on LED Panel 

Open or short circuit in room 
temperature sensor. 

Contact Customer Service. 
 

“E1” Displayed 
on LED Panel 

Open or short circuit in pipe 
temperature sensor. 

Contact Customer Service. 

“E3” Displayed 
on LED Panel 

Open or short circuit in defrost 
temperature sensor. 

Contact Customer Service. 

‘WATERFULL’ 
Indicator ON 

Water tank is full 

Empty residual condensate 
water. 

 
 

 
 

Summary of Contents for PKY12

Page 1: ...12000BTU Mobile Air Conditioner Model PKY12 Please read and retain these instructions for future reference...

Page 2: ...omfort by adjusting the temperature and humidity in a room Its mobility makes it easy to use in various rooms To ensure the optimal efficiency of the air conditioner we advise you to keep doors and wi...

Page 3: ...ds 13 DO NOT let chemical substances come into contact with the appliance 14 DO NOT use the appliance in the presence of flammable substances or such as alcohol insecticides petrol etc 15 DO NOT use t...

Page 4: ...connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 Th...

Page 5: ...HI AUTO h ON OFF CONT TIMER T EMP Drainage outlet Please transport this product in an upright position only and place the product on a stable level surface ACCESSORIES Indoor adaptor for insertion ov...

Page 6: ...on a flat level surface at least 50cm from any objects DO NOT plug it in until exhaust hose is installed Installing the exhaust hose Use only the hose provided and clip exhaust hose and indoor adapto...

Page 7: ...ways try to keep air filter clean To prevent conditioned air from escaping keep windows doors and any other openings closed CONTROL PANEL LED DISPLAY 1 Auto Mode Icon 2 Fan Speed 3 Cooling Mode 4 Swin...

Page 8: ...n can be activated to the timed switching off mode only when the unit is switched ON Timer function can be activated to the timed switching on mode only when the appliance is turned off POWER Indicato...

Page 9: ...M L fan speed as you like by pressing SPEED button The product will deliver cooled air when room temperature is above 26O C The product will operate in DRY MODE when room temperature is between 23O C...

Page 10: ...tem to start operating again the water inside the unit required draining in one of the following ways 1 Turn off the air conditioner and unplug from the power socket While the reservoir is full avoid...

Page 11: ...RFULL indicator flashing Is the room temperature below the set temperature The machine seems to have little cooling effect Is there direct sunshine Please close the curtains or blinds Are too many win...

Page 12: ...roducts should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice EHS Manchester M17 1RN EHS 01 07 ONE 1 YEA...

Reviews: