Read and save these important safety instructions before using this 
unit. When using electrical appliances, basic safety precautions should 
always be followed: 

 

1. 

Transport & store the unit in an upright position only.  Leave it in an 
upright position for at least 3 hours before first use. 

2. 

Always place the unit on an even, level surface. 

3. 

An opening in a window or wall is required to accommodate the exhaust 
hose. 

4. 

Ensure the unit is connected to an earthed power supply of the correct 
rating. (Refer to the rating label located at the back of the unit).  

5. 

The unit will cool when the room temperature is between 15°C~32°C 
depending on the thermostat setting. 

6. 

Operate this unit in an ambient temperature of 32°C or lower. 

7. 

DO NOT use this unit for functions other than those described in this 
instruction manual. 

8. 

DO NOT tilt the unit.  

9. 

DO NOT cover or obstruct the appliance’s inlet and outlet grilles.  

10.  Your air conditioner has been designed to be used only in the home, 

office and similar conditions and should not be used for any other 
purpose. 

11.  Never unplug the air conditioner while it is working, this could damage 

the electronic circuits. 

12.  DO NOT use the appliance in a wet room, such as a bathroom or 

laundry room to avoid the risk of electrical shocks.  

13.  Do not bend or crush the warm air exhaust hose. 
14.  DO NOT sit or place articles on the appliance. 
15.  DO NOT use the appliance with wet or damp hands. 
16.  DO NOT let chemical substances come into contact with the appliance. 
17.  DO NOT use the appliance in the presence of flammable substances or 

vapours such as alcohol, insecticides, petrol, etc. 

18.  DO NOT use the plug to start and stop the appliance. ALWAYS use the 

control panel to start and stop the unit. 

 

19.  ALWAYS keep an air path of at least 50cm from walls, furniture or 

curtains.   

20.  ALWAYS turn off the appliance when it is not in use and remove the 

mains plug from the socket outlet.  

21.  ALWAYS turn the unit off and remove the mains plug before cleaning, 

carrying out maintenance or moving location. 

Summary of Contents for PAC1130

Page 1: ...T TI IO ON NE ER R w wi it th h H He ea at t p pu um mp p I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L Model PAC1130 10 000 BTU HR Model PAC1140 14 000 BTU HR IMPORTANT Please read these instr...

Page 2: ...ruction 3 4 BS Plug Wiring 5 Technical Specification 6 7 Energy Saving Advice 8 Product Description 9 Control Panel 10 Remote Control Functions 11 Use of Control Panel 12 14 Remote Control Operation 1...

Page 3: ...e appliance s inlet and outlet grilles 10 Your air conditioner has been designed to be used only in the home office and similar conditions and should not be used for any other purpose 11 Never unplug...

Page 4: ...The filter must be used with the product at all times when removing it for clearing always turn the unit off and unplug the mains plug from the socket 25 Do not operate the unit with a damaged power c...

Page 5: ...and must be connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or colour...

Page 6: ...cm Dimensions Packaged 87 x 44 5 x 48 5 cm Refrigerant R410A 0 55 kg NOTE 1 The above cooling capacity is measured at ambient temperature 27 C Relative Humidity 60 2 Noise level is measured at a poin...

Page 7: ...cm Dimensions Packaged 96 5 x 49 5 x 54 5 cm Refrigerant R410A 0 75 kg NOTE 5 The above cooling capacity is measured at ambient temperature 27 C Relative Humidity 60 6 Noise level is measured at a poi...

Page 8: ...floor and or wall grilles so cool air does not escape through the chimney or ductwork 4 Keep the filters clean 5 Avoid opening doors frequently 6 Each person present in a room provides between 100 150...

Page 9: ...9 P Pr ro od du uc ct t D De es sc cr ri ip pt ti io on n...

Page 10: ...10 C Co on nt tr ro ol l P Pa an ne el l...

Page 11: ...11 R Re em mo ot te e C Co on nt tr ro ol l F Fu un nc ct ti io on ns s...

Page 12: ...ays the room temperature and operates in Auto mode 2 Selecting operating mode Press the Mode button to select the desired mode as show below 3 Adjusting temperature The adjustable temperature range is...

Page 13: ...er fan will run at low speed the speed is not adjustable 2 The compressor and lower fan runs will stop running after 8 minutes then run again after 6 minutes automatically 3 Temperature control is ino...

Page 14: ...ge airflow direction The unit default setting is straight airflow 2 Press Swing button once the airflow direction will change to swing at 120O right left 9 Sleep operation 1 The sleep operating is eff...

Page 15: ...The batteries must be removed from the remote control before it is scrapped and dispose of them responsibly Note Batteries contain materials which are hazardous to the environment they must be remove...

Page 16: ...he exhaust air duct by pulling out the two ends of the duct 2 Screw the exhaust air duct into the mid connector 3 Screw the exhaust air duct into the outlet connector wall or fish tail 4 Screw the mid...

Page 17: ...used to exhaust the hot air z Exhaust hot air from window Open window slightly and use the fishtail Close the window as much as possible leaving the fishtail outside z Exhaust hot air from door Open d...

Page 18: ...1 Air exhaust duct can be extend from 0 55 to 1 8 meters the unit works more efficiently if the duct is shorter 2 Ensure the air exhaust duct is not folded or kinked as this impedes the unit s effici...

Page 19: ...te If the air filter is blocked with lots of dust the airflow volume will decrease Suggest cleaning the filter once every two weeks or more frequently if necessary Let the filter dry thoroughly before...

Page 20: ...rain the water continuously 1 Disconnect the rubber plug from continuous drainage pipe Store the disconnected rubber plug for future use 2 Connect supplied drainage pipe to drainage hole condensed wat...

Page 21: ...set Cancel the TIMER or wait for timer to initiate Not working In cooling mode 1 The room temperature is lower than the set temperature It is normal No cold air is being delivered 1 There is frost on...

Page 22: ...should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice EHS Manchester M17 1RN EHS02 08 ONE 1 YEAR LIMITED...