3
INSTALLATION
The EH1688 must be permanently fixed to a wall, door frame or ceiling and
permanently connected to the mains supply by a qualified electrician to current
approved wiring regulations. The unit can be fixed using bolts through the main
holes or by four smaller screws on either side of the main holes. In any situation
the unit needs to be installed in the correct way with the securing screws firmly in
place.
To begin draw a horizontal line on the wall approx. 400mm long and mark the centre
point. Mark 2 points 180.5mm either side of the centre point and then two points
30mm either side of the two main points. Drill either two holes either side of the
main fixing points or two holes on the main points then insert the correct wall plugs
or bolts.
The bracket can now be firmly fixed to the wall/ceiling.
Once the bracket is correctly fitted to the wall or ceiling the heather can be slotted
onto the bracket and the bolts tightened into place. The 2 securing screws should
be fitted to ensure the unit cannot be accidentally removed or knocked off.
The unit is supplied with a 3 function remote control, this will require the fitting of 2
AAA batteries for correct operation.
Securing Screw