background image

GENERAL SAFETY REQUIREMENTS

 

Domestic  wiring  must  be  tested  periodically  by  a  qualified  electrician  at  least 
once every 10 years or at every change of occupancy. 
For office and retail premises, and buildings such as village halls, the wiring must 
be inspected at least once every 5 years. 
It is recommended that all buildings be fitted with smoke alarms (it is mandatory 
for new buildings) 

OPERATING COSTS 

At time of going to press, the average cost of electricity is £0.13 per unit (kilowatt-
hour). The amount you are being charged will be shown on your electricity bill. 
At this cost, the running costs will be as follows: 

EH1550  £0.07 per hour 
EH1552  £0.13 per hour 
EH1554  £0.21 per hour 
EH1556  £0.26 per hour 

These figures apply with the temperature programmed to its highest setting.  
The  running  costs  will  be  lower  if  programmed  to  a  lower  temperature,  or  if  the 
ambient temperature is higher. 

 

 

 

OPERATION 

Plug the mains lead into a 13 Amp mains socket. 
If connecting via an extension lead, make sure that the lead is rated at 13 Amps, 
and that it is fully unwound. 
Switch  the  unit  on  at  the  mains  socket,  and  at  the  switch  on  the  side  of  the 
heater. The display will flash briefly, then will show the current room temperature, 
and the operating mode. There are six operating modes: 

-1, 

-2,  , 

 and 

P

The modes are as follows: 

 

= comfort mode. 

-1 

= 1°C below comfort mode temperature

 

-2 

= 2°C below comfort mode temperature

 

   

= economy mode (3½°C below comfort mode temperature) 

 

= frost protection mode (keeps the temperature above 7°C) 

P

  =  program  mode  –  the  heater  is  controlled  by  a  7-day  programmable  timer, 

which can be programmed as detailed below. 
To change mode press MODE repeatedly until the symbol for the required mode 
is displayed. 

Summary of Contents for EH1550

Page 1: ...1 EH1550 EH1552 EH1554 EH1556 500 W 1 kW 1 5 kW 2kW Programmable Panel Heater Chauffage Radiant Programmable ...

Page 2: ...es at the back of the heater Attach two castor wheels to each bracket using the dome nuts provided To wall mount Depress the two clips and remove the wall mounting bracket from the heater Using the bracket as a template and using a spirit level to makes sure that the bracket is fitted level drill four holes in the wall the lower holes should be be at least 160 mm above the floor Insert a wall plug...

Page 3: ...ion Place the heater on a firm flat surface Ensure that the air inlets at the bottom and the air outlets at the top are not obstructed Ensure that curtains are at least 900mm 3 from the top of the heater Leave a gap of at least 50mm 2 at the sides of the heater If used free standing do not operate unless the feet are correctly attached Do not place on soft surfaces Do not cover This symbol shown o...

Page 4: ...grammed to its highest setting The running costs will be lower if programmed to a lower temperature or if the ambient temperature is higher OPERATION Plug the mains lead into a 13 Amp mains socket If connecting via an extension lead make sure that the lead is rated at 13 Amps and that it is fully unwound Switch the unit on at the mains socket and at the switch on the side of the heater The display...

Page 5: ...de represents 1 C below comfort mode represents 2 C below comfort mode represents Economy mode 3 C below comfort mode represents Frost protection mode Press the or keys until the symbol is above the correct day of the week Press P again and the clock will be displayed with the hours digits flashing If the clock is not correct adjust the hours using the and buttons Press P again and the clock will ...

Page 6: ...icate that the panel is locked Do not touch the case when the heater is in operation because it will be hot Unplug the heater from the mains when not in use MAINTENANCE Before cleaning turn the heater off and disconnect from the mains supply The heater may then be cleaned using a damp cloth with a drop of washing up liquid to remove any dust or dirt from the case Do no use stronger detergents or s...

Page 7: ...s and together and hold for 3 seconds to unlock it DISPOSAL AND RECYCLING You must not dispose of this appliance with domestic household waste Most local authorities have specific collection system for appliances and disposal is free of charge to the end user When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for disposal TECHNICAL SPECIFICAT...

Page 8: ...ught it The retailer s contact details will be on the invoice that arrived with the product or on the e mail you received when you placed the order Do not contact Prem i air only your retailer can arrange a replacement If your product fails within the guarantee period firstly read the fault finding section of this manual because temperature and weather conditions can affect the performance of cert...

Page 9: ...upport se place sur l arrière du radiateur Fixez les deux roulettes sur chaque support à l aide des écrous à dôme fournis Pour une installation murale Appuyez sur les deux clips et et ôtez l étrier de fixation murale du radiateur En utilisant l étrier comme un gabarit et un niveau à bulles percez quatre trous dans le mur Les trous les plus bas doivent être percés à au moins 160mm du sol Insérez un...

Page 10: ... le placez pas sur une surface molle ou instable Ne pas couvrir Ce symbole situé sur le radiateur signifie que celui ci ne doit pas être couvert afin d éviter une surchauffe Pour utilisation à l intérieur uniquement Ne pas utiliser dans les alentours immédiats d une salle de bains d une cabine de douche ou d une piscine Ne placez pas le cordon d alimentation sous un tapis ou une carpette N utilise...

Page 11: ...modes sont les suivants mode confort 1 1 C en dessous de la température du mode confort 2 2 C en dessous de la température du mode confort Mode économique 3 C en dessous de la température du mode confort Mode protection contre le gel maintient la température au dessus de 7 C P mode programme le radiateur est contrôlé par un un programmateur sur 7 jours qui peut être programmé comme détaillé ci des...

Page 12: ...le soit affiché au dessus du bon jour de la semaine Appuyez de nouveau sur P et l horloge s affichera avec les chiffres des heures qui clignotent Si horloge n est pas à la bonne heure utilisez les boutons et pour la régler Appuyez de nouveau sur P et les chiffres des minutes clignoteront Si horloge n est pas à la bonne heure utilisez les boutons et pour la régler Appuyez de nouveau sur P et le sym...

Page 13: ... 3 secondes La fonction peut être déverrouillée pour donner accès à la programmation en appuyant sur les boutons et en même temps pendant 3 secondes L affichage indique _ _ pour signaler que le panneau de contrôle est verrouillé Ne touchez pas le radiateur pendant qu il est en fonctionnement car il est chaud Débranchez le radiateur quand vous ne l utilisez pas COUT DE FONCTIONNEMENT Au moment où c...

Page 14: ...e qui déconnecte l appareil si l élément de chauffage est trop chaud La raison la plus courante en cas de surchauffe est que les entrées ou sorties d air sont obstruées ou que les grilles sont bloquées Si le radiateur cesse de fonctionner laissez le refroidir pendant 20 minutes puis vérifiez que les grilles ne sont pas obstruées Remettez le en fonctionnement et vérifiez que le produit fonctionne à...

Page 15: ...119 mm Dimensions posé au sol EH1550 440x450x238 mm EH1552 543x450x238 mm EH1554 683x450x238 mm EH1556 983x450x238 mm Poids EH1550 3 2 kg EH1552 4 01 kg EH1554 4 85 kg EH1556 6 5 kg Alimentation 230 V CA Consommation EH1550 500 W EH1552 1 kW EH1554 1 5 kW EH1556 2 kW Courant de Fonctionnement EH1550 2 2 A EH1552 4 3 A EH1554 6 5 A EH1556 8 7 A ...

Page 16: ...mail que vous avez reçu quand vous avez passé votre commande Ne contactez pas Prem i air seul votre revendeur peut s occuper du remplacement du produit Si votre appareil tombe en panne pendant la période de garantie veuillez tout d abord consulter la section défauts de fonctionnement de votre notice d utilisation car la température et les conditions climatiques peuvent affecter la performance de c...

Reviews: