Prem-I-Air EH1419 Instructions Manual Download Page 5

Page 5 

OPERATION 

Leave the appliance in an upright position for 3 hours before 
first use. 
Plug the mains lead into a 13 Amp mains socket.  
If connecting via an extension lead, make sure that the lead 
is rated at 13 Amps or more, and that it is fully unwound. 
Switch the unit on at the mains socket.  

POWER

 

Button: 

Press  the  "Power"  button  to  start  the  unit. 

The Power indicator illuminates when the appliance is ON. 
Press  the  POWER  button  again  to  stop  the  appliance.  The 
fans  and  compressor  will  not  stop  immediately,  but  will  go 
through a shut-down sequence lasting a few seconds. 
 

TEMP+ and TEMP- buttons: 

Use  the  +  and  -  buttons  to  select  the  desired  zone 
temperature. The temperature can be set to any temperature 
from  16  °C  to  30  °C.  Selecting  a  higher  temperature  will 
reduce  power  consumption.  The  target  temperature  is 
dislayed  in  the  right-hand  two-digit  display.  The  left-hand 
two-digit display shows the current room temperature. 
For  spot  cooling,  or  to select a target temperature below 16 
°C,  hold  down  the  COOL  button  for  3  seconds.  The  display 
will then change to "00". The target temperature may now be 
adjusted to any value between 0 °C and 30 °C. 
 

FAN SPEED button. 

Press the FAN SPEED button to change the fan speed. 
 

Summary of Contents for EH1419

Page 1: ...Page 1 EH1419 7 3 kW 25000 BTU hour Mobile Industrial Spot Cooler Spot Cooling LED display panel 4 Hour timer...

Page 2: ...urs for the refrigerant gas to stabilise before use INSTALLATION Attach the two handles to the rear panel of the appliance Remove the four screws from the top left and right sides of the rear panel Us...

Page 3: ...c wiring must be tested periodically by a qualified electrician at least once every 10 years or at every change of occupancy For office and retail premises and buildings such as village halls the wiri...

Page 4: ...re that there is at least 300mm 1 between the sides of the appliance and any flammable materials Ensure that there is at least 900mm 3 from the top of the appliance and any flammable materials Do not...

Page 5: ...diately but will go through a shut down sequence lasting a few seconds TEMP and TEMP buttons Use the and buttons to select the desired zone temperature The temperature can be set to any temperature fr...

Page 6: ...ter switch the unit off by pressing the ON OFF button Remove the tank located in the larger compartment on the right side panel and empty the collected water down a drain Replace the tank ensuring tha...

Page 7: ...to run in heating cooling or dehumidifying modes and 0 04 per hour to run in the fan only mode To minimise the power used and reduce operating costs Make sure that the filter is kept clean Make sure t...

Page 8: ...mpressed air blower The filter should be cleaned every two weeks to maintain optimum performance Using a dry 1 25mm paint brush remove any dust from the grilles Use a compressed air blower to remove d...

Page 9: ...In cooling mode no cool air is produced Zone temperature is lower than set temperature The unit is defrosting this will take a few minutes and afterwards it will resume operation Filter is blocked Co...

Page 10: ...ned air from escaping and to prevent exhaust air from re entering the room Use blinds to prevent direct sunlight reaching the room Set the temperature higher whilst cooling or lower whilst heating DIS...

Page 11: ...idifying capacity 35 litres day Temperature setting cooling 18 30 C Refrigerant R410a 1 kg FLUORINATED GASES The appliance contains refrigerant gas which is subject to control under the Fluorinated Gr...

Page 12: ...indicated on the unit or any attempts made to service or modify the unit then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is...

Reviews: