INSTALLATION 

Place the appliance on a firm, flat level surface. 
If  continuous  drainage  is  to  be  used,  unscrew  and  remove  the  bung  from  the 
drainage port (on the back of the appliance, half-way up, on the right-hand side), 
and connect a drainage hose to the port. Use a hose with an internal diameter of 
12mm  (½").  Make  sure  that  the  hose  runs  downwards  throughout  its  entire 
length, and has no kinks. Otherwise the drainage will not work. 
The bung can be stored in the bucket in case it is required at a later date. Make 
sure that the bucket is fitted correctly into the housing. 
 

OPERATION 

• 

Plug the mains lead into a 13 Amp mains socket. 

• 

If  connecting  via  an  extension  lead,  make  sure  that  the  lead  is  rated  at  5 
Amps, and that it is fully unwound. 

• 

Place the appliance on a firm flat level surface.

 

• 

Switch the appliance on at the mains socket. Then press the power switch to 
start  operation.The  appliance  will  wait  for  3  minutes  whilst  the  refrigerant 
settles before starting to operate, this is to extend the life of the compressor. 

• 

Using the + and ˜ buttons, set the required humidity level on the display. The 
level can be set between 35% and 80% in 5% increments. The appliance will 
remove  humidity  from  the  air  whenever  the  humidity  level  is  higher  that  the 
set level. 

• 

After a delay of 5 seconds, the display changes to showing the present room 
humidity level. 

• 

To  select  continuous  operation,  press the 

CONT.

 button. The appliance will 

continuously  remove  humidity  from  the  air  regardless  of  the  humidity  level. 
Press the 

CONT.

 button again to stop continuous operation.  

• 

Take  particular  care  if  selecting  continuous  operation  when  continuous 
drainage  is  being  used.  It  will  lead  to  a  continous  reduction  of  humidity 
levels;  which,  if  the  humidity  becomes  too  low,  may  lead  to  the  cracking  of 
delicate wooden items. 

• 

If  operating  at  an  ambient  temperature  below  10  °C,  the  internal  heat 
exchanger  will  drop  below  0  °C,  causing  ice  to  form.  If  this  happens,  the 
appliance  will  automatically  defrost:  when  this  happens  P1  will  be  shown  in 
the display. 

• 

Unplug  the  appliance  from  the  mains  when  not  in  use.    (Do  not  disconnect 
whilst still operating, press the power switch to turn the appliance OFF first) 

• 

Check the appliance regularly for damage and cease using it immediately if 
any damage to the product, the cable or the mains plug is found. 

• 

The appliance operates best if it is in an enclosed area. Close all doors and 
windows,  and  eliminate  sources  of  additional  humiditiy,  such  as  cooking, 
clothes drying. Cover fish tanks. 

• 

The most comfortable setting for the humidity level is around 50%.  

 

Summary of Contents for EH1418

Page 1: ...Page 1 EH1418 Compressor Dehumidifier D shumidificateur Compresseur...

Page 2: ...e on a firm flat stable surface Make sure that air intakes and exhausts are not obstructed For indoor use only Do not place this appliance within 400mm 16 of curtains or similar items Ensure that the...

Page 3: ...midity from the air whenever the humidity level is higher that the set level After a delay of 5 seconds the display changes to showing the present room humidity level To select continuous operation pr...

Page 4: ...ing FLUORINATED GASES The appliance contains refrigerant gas which is subject to control under the Fluorinated Greenhouse Gases Regulations 2009 It is a criminal offence knowingly to allow the refrige...

Page 5: ...cloth with a drop of washing up liquid to remove any dust or dirt from the case Do no use stronger detergents or solvents as these may damage the surface finish Clean the inside of the bucket to preve...

Page 6: ...on page 6 Do not drink the water it may be used for watering plants Bucket is not replaced properly Ensure that the bucket is correctly aligned with the housing Appliance stops operating and P1 is dis...

Page 7: ...our electricity bill At this cost the appliance will cost 0 03 per hour to run on the continuous setting If the humidistat is used the operating costs will be lower TECHNICAL SPECIFICATION Dimensions...

Page 8: ...iquement Ne placez pas l appareil moins de 400mm des rideaux ou produits similaires Pour utilisation l int rieur uniquement Ne pas utiliser dans alentours imm diats d une salle de bains d une cabine d...

Page 9: ...r l cran Le niveau peut tre r gl entre 35 et 80 par paliers de 5 L appareil enl vera l humidit de l air quand le taux d humidit est sup rieur au taux r gl Au bout de 5 secondes l affichage change et i...

Page 10: ...ULL s allume Tirez un peu le bac vers l ext rieur Soulevez le bac Videz l eau dans l vier RANGEMENT Si vous n utilisez pas l appareil pendant longtemps 1 Videz et nettoyez le bac eau 2 D branchez l ap...

Page 11: ...e est particuli rement poussi reuse Pour nettoyer le filtre enlevez tout d abord le bac eau l onglet du filtre sera alors visible derri re la grille avant Appuyez sur l onglet vers l int rieur et tire...

Page 12: ...ive pendant les journ es d t tr s ensoleill es et s ches ou pendant les journ es d hiver tr s froides et s ches Il y a de la condensation sur les fen tres caus e par la diff rence de temp rature entre...

Page 13: ...x b timents CODES PANNES F1 Le capteur d humidit est d fectueux F2 Le capteur de temp rature est d fectueux Si l un de ces d fauts est d tect teignez l appareil en appuyant sur le bouton on off puis d...

Page 14: ...du Bac Eau 1 5 litres Niveau Sonore 45 dB A Surface d Efficacit 15 m 2 ELIMINATION ET RECYCLAGE Vous ne devez pas jeter cet appareil avec les ordures m nag res car il contient un gaz r frig rant soum...

Page 15: ...lease call our Help Desk on 0845 459 4816 Prem i Air Appliances Ltd Lancots Lane Sutton St Helens Merseyside WA9 3EX website www prem i air com GARANTIE Prem I Air garantit le produit contre tout d fa...

Reviews: