Prem-I-Air EH0530 Instruction Manual Download Page 1

 

 

8000BTU WALL MOUNTED AIR 

CONDTIONER 

COOLING & HEATING 

Model EH0530 (PMINISW8W) 

 

 

(Refrigeration R407C) 

 

 

PLEASE READ THIS INSTRUCTION MANUAL   

BEFORE OPERATING AND KEEP 

SAFE FOR FUTURE REFERENCE 

Summary of Contents for EH0530

Page 1: ...8000BTU WALL MOUNTED AIR CONDTIONER COOLING HEATING Model EH0530 PMINISW8W Refrigeration R407C PLEASE READ THIS INSTRUCTION MANUAL BEFORE OPERATING AND KEEP SAFE FOR FUTURE REFERENCE...

Page 2: ...plug wiring Schuko to UK converter plug Optional 7 E Product description 8 9 F Wall mounting installation instructions 9 13 G Operating instructions 14 17 H Operation using remote controller 18 19 I...

Page 3: ...Noise Level dB 50 Refrigerant g R407C 400g Net Weight KG not includes accessories 32 Dimension H W D 465 765 235 465 765 235 536 930 315 536 930 315 Use Type V5 remote controller only Notes 1 Cooling...

Page 4: ...z The manufacturer cannot be held liable for damage caused to property or injury to persons or animals due to incorrect installation regulation and maintenance or improper use z This air conditioner c...

Page 5: ...z DO NOT use the appliance in the presence of flammable substances or vapours such as alcohol insecticides petrol etc z DO NOT use the plug to start and stop the appliance ALWAYS use the intended cont...

Page 6: ...ording the legislation in force in the country concerned READ AND SAVE THESE INSTRUCTIONS PLEASE NOTE RECEIVING THE GOODS z The air conditioner is delivered in protective packaging and is accompanied...

Page 7: ...OWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or colored RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with t...

Page 8: ...hole using in mobile version only 4 Control panel 11 Air exhaust 5 Handles 12 Air inlet 6 Dust filter 13 Drainage hole 7 Hanging holes for wall mount brackets 14 Caster bracket hanging hole using in...

Page 9: ...do so could cause potential installation problems z The air conditioner must be installed on an exterior wall that has access to the outside and a minimum of 2 meters free clearance to allow good air...

Page 10: ...uld be hidden by the construction of the wall for example Electrical wiring water gas pipes or supporting lintels or beams z Ensure that a spirit level is used as the unit must be level z Follow the i...

Page 11: ...es condensate that has to be extracted to enable the unit to operate correctly It is necessary to drill a hole through the wall measuring 30mm in diameter in the position shown in the template z It is...

Page 12: ...the wall with the ring and push all the way to the outside Pull the nylon cords towards you and with a little manipulation the rubber ring will fit onto the exterior wall If you are installing the un...

Page 13: ...sing the other supplied pipe with diameter 120mm 5 Remove the Rubber Plug 6 Fitting the unit on bracket After checking again that the fastening bracket is securely fastened to the wall and that any ne...

Page 14: ...temperature display Control Panel Functions 1 On Off Starts or Stops the Unit 2 Mode Select the functions on the unit for Auto Mode the 88 LED shows AU Cooling Mode the 88 LED shows CO Dehumidifying M...

Page 15: ...n until CO appears on the LED display z Press UP or DOWN until the desired room temperature appears on the LED The temperature ranges from 16 C 31 C z Select desired fan speed by pressing the FAN Butt...

Page 16: ...on the LED The temperature ranges from 16 C 31 C z Select the fan speed by pressing the Fan button It is recommended to use the low fan NOTE When activating the heat pump the unit will shut off for 3...

Page 17: ...r 6 hours The temperature will then return to the originally set figure z When in heating mode during the first two hours temperature will be decreased 2o C per hour Then temperature will be keeping a...

Page 18: ...t going to be used for an extended period of time A CHANGE IN THE FUNCTION IS USUALLY INDICATED BY A BEEP 8 Do not abuse the remote control 9 Do not place the remote control in a location that is expo...

Page 19: ...e unit for Auto Mode Cooling Mode Dehumidifying Mode Fan Mode and Heating Mode 5 FAN Select the fan speed desired High Medium Low 6 SLEEP To set the unit for sleep mode 7 SWING To start swinging air l...

Page 20: ...closed position during manufacture for use in cooling mode You are recommended to close it in wintertime to stop cool air from outdoors entering or in heating mode Loosen the 2 buttery screws in both...

Page 21: ...the air filter by immersing it gently into warm about 40o C water with a neutral detergent Rinse the filter and dry it thoroughly in a shaded place c Replace the filter back into the filter compartmen...

Page 22: ...l run when the defrosting is finished The remote control does not work 1 Exhausted batteries 2 Batteries incorrectly installed 1 Change the batteries 2 Re install the batteries correctly The unit does...

Page 23: ...ed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Prem I Air Appliances Ltd Lancots Lane Sutton Oak St Helens WA9 3EX UK...

Reviews: