Maintenance 

The Quantum Series is designed to require little to no maintenance. The following 

recommended maintenance items will help keep the Quantum Series operating correctly and 

minimize any down time on your packaging line. If there are any questions regarding the 

maintenance of the Quantum Series, please contact your local Pregis Service Technician for 

assistance. 

 

 

 

 

 

 

 

 

 

Electrical shock or unexpected machine movement can cause injury. Unplug the machine 

before performing maintenance tasks. 

 

Disconnect the power cord before performing ANY maintenance to the machine other than 

inspections. 

 

 

Monthly Maintenance: 

 

 

1. Machine should be cleaned periodically to maintain a clean work environment.  

 

2. Verify all components are working properly. If there are any issues, please contact your 

Pregis Service Technician 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for EASYPACK QUANTUM Series

Page 1: ...2018 Pregis Corporation All Rights Reserved EASYPACK QUANTUM SERIES PAPER PACKAGING BY PREGIS User Manual v1 2...

Page 2: ...fety reliability and enhanced ergonomic features that increase operator productivity System Snapshot Quantum XT Low medium volume applications centralized workstations coverts paper rolls Quantum XTW...

Page 3: ...ipment isolated from power supply and no longer in motion 3 Never deface or remove factory installed warning decals If a decal ever becomes lost damaged or illegible report this condition to a supervi...

Page 4: ...ng the Quantum Series the most commonly used component is the foot pedal may need to extend head to insert foot pedal using the telescoping function Its functions include Starting and stopping the mac...

Page 5: ...5 Head Assembly Controls...

Page 6: ...te the machine if you are under the influence of alcohol drugs or medications that can make you less alert or affect your judgment Operating Modes Manual Mode Manual Feed to Length FTL Mode Auto Feed...

Page 7: ...so acts as an override To receive a length of material greater than the preset length press and hold the foot pedal until the desired length is received The preset length can be adjusted using the add...

Page 8: ...greater than the preset length press and hold the foot pedal until the desired length is received The preset length can be adjusted using the add subtract buttons on head assembly as needed Preset Le...

Page 9: ...this feature simply pull the void fill material against the tear assist in a downward motion as shown below The tear assist will pivot downward slightly which activates an internal switch Once the sw...

Page 10: ...nsert the paper over the breaker bar if equipped through the inlet and below the upper roller assembly Position the material forward of the drive rollers and above the tear assist 1 Place a roll of Qu...

Page 11: ...11 Quantum XTW Magazine Loading Fanfold Paper...

Page 12: ...12 Quantum XTW Magazine Loading Fanfold Paper Cont d...

Page 13: ...ies please contact your local Pregis Service Technician for assistance Electrical shock or unexpected machine movement can cause injury Unplug the machine before performing maintenance tasks Disconnec...

Page 14: ...f 2 Check power cord Make sure it is plugged in correctly to a good known power source 3 Verify power switch is in the On I position Problem Machine is powered on but will not run Cause Head assembly...

Page 15: ...15 Quantum XT Machine Specifications Machine Weight 35 lbs Machine and Floor Stand 75 lbs Power Requirements 3 Amps Side Profile Overhead...

Page 16: ...16 Quantum XTW Machine Specifications Machine Weight 35 lbs Machine and Floor Stand 75 lbs Magazine Weight Un loaded 115 lbs Power Requirements 3 Amps Front Side Profile Overhead...

Reviews: