Page 6
For technical questions, please call 1-888-866-5797.
ITEM 63086
S
AFETY
S
ETU
p
Op
ERA
TION
M
AINTENANCE
Functional Description
Specifications
Generator
Output
120 / 240 VAC, 60 Hz
7,000 Running Watts (8,750 max. starting Watts)
Battery needed for electric start
(not included)
12 V, lead acid, 9 Ah
Electrical Receptacle
Two 3-Prong, duplex NEMA #5-20 120 V GFCI
One 3-Prong, NEMA #L5-20 twistlock 120 V
One 4-Prong, NEMA #L14-30 twistlock 120 V / 240 V
One DC Outlet 12 VDC
Engine
Displacement
420 cc
Engine Type
Horizontal Single Cylinder 4 stroke OHV
Cooling System
Forced air cooled
Fuel
Type
87+ octane stabilizer treated unleaded gasoline
Capacity
6.6 Gallons (25 L)
Engine Oil
Type SAE
10W – 30 above 32° F
5W – 30 at 32° F or below
Capacity
1.16 Quart (1.1 L)
Spark Plug
Type
NHSP
®
/ Torch
®
F6TC
Gap
0.028" – 0.031"
Valve Clearance (Intake/Exhaust)
0.002" – 0.004"
Run Time @ 50% load
12 hr.
Operational Volume
76 dB
Available accessories
Wheel kit (sold separately)
The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental
Protection Agency. For warranty information, refer to the last pages of this manual.
Components and Controls
Fuel Cap
Frame
Starter
Handle
DC Circuit Breaker
Fuel Valve
Power Switch
AC Circuit Breakers
Choke
Low Oil Indicator
GFCI AC Receptacles
Air Filter
DC Receptacle
Ground Terminal
AC Receptacles