Step-up Pulley/Tensioner Assembly Exploded View
Procedure
Review entire procedure before starting.
Removal Instructions
1. Remove the Drive Access cover, see
2. Remove the left and right Drive Disk covers, see
.
3. Remove the left and right Stairarms from the Input Crank, see
.
4. Remove the Drive Top and left/right Drive Housing covers see
.
5. Remove the Drive Components assembly, see
"Drive Components assembly Replace-
TIP
: For machines with mfg. dates prior to 01/02/2019, the Step-up Pulley/Tensioner
assembly spacers (2x) and bolt isolators (4x) can easily fall out of the mounting holes.
Take care to keep track of these components for installation, see
ley/Tensioner Assembly Exploded View" above
.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 105
6 Replacement Procedures
Step-up Pulley/Tensioner Assembly Replacement