Procedure 2.1 - Accessing the Diagnostic Software
The C944 Treadmill's diagnostic software consists of the following modes:
•
Display Test
•
Manual Lift Adjust
•
Troubleshoot Lift
•
Software Version
•
Power Bits
•
Keypad Test
Procedure
1.
Plug the power cord into the wall outlet, then turn on the treadmill with the circuit breaker.
2.
With the
PRECOR C944
banner scrolling, press the
SPEED
▲
,
SPEED
▼
and
INCLINE
▲
keys
simultaneously or keys
RESET,5,1,7,6.5.7.6,1
, sequentially on units with standard
access codes (see Diagram 2.1).
3.
Watch the electronic display as the LED test progresses. This test is programmed to display
the following LED illumination sequence.
a
Every LED on the left display window illuminates simultaneously
b
The lower row of the display window cycles from red to yellow to green.
c
Diagonal lines of illuminated LEDs sweep across the left display window.
d
The right display windows illuminate, then decrement from 8.8.8.8 to 0.0.0.0.
e
The function LEDs illuminate simultaneously and then extinguish.
f
Each function LED illuminates separately and then extinguishes.
4.
If you do not observe the LED illumination sequences described in Step 3
...
THEN...
OTHERWISE...
Replace the upper PCA as described
The LED passed successfully;
in Procedure 5.2 of the Commercial
continue with the next step.
Treadmill Service Manual.
Summary of Contents for c944
Page 39: ...C944 Treadmill Page 39 Wiring Diagram 7 1 C944 SCR 120 Vac J9...
Page 40: ...C944 Treadmill Page 40 Block Diagram 7 2 C944 SCR 120 Vac...
Page 42: ...C944 Treadmill Page 42 Block Diagram 7 4 C944 SCR 240 Vac...
Page 43: ...C944 Treadmill Page 43 Wiring Diagram 7 5 C944 PWM 120 Vac F1 Lift Fuse 2A Slow Blow...
Page 44: ...C944 Treadmill Page 44 Block Diagram 7 6 C944 PWM 120 Vac...
Page 45: ...C944 Treadmill Page 45 Wiring Diagram 7 7 C944 PWM 240 Vac F1 Lift Fuse 2A Slow Blow...
Page 46: ...C944 Treadmill Page 46 Block Diagram 7 8 C944 PWM 240 Vac...