C542i Elliptical Fitness Crosstrainer
Page 13
Section Four - Checking EFX Operation
This section provides you with a quick method of checking EFX operation. Check the operation
of the EFX at the end of most maintenance procedures.
Procedure
1.
Start striding on the EFX or plug the optional external power supply (when available) into the
EFX and the AC outlet.
2.
At the
PRECOR
banner, press
QUICK START
.
3.
Select Resistance Level 1 and press
ENTER
.
4.
Operate the EFX for 4–5 minutes. As you operate the EFX, concentrate on the operating
sounds made by the unit. Be on the alert for unusual rubbing, hitting, grinding, or squeaking
noises.
5.
If the EFX makes unusual noises or the electronic display does not change appropriately,
troubleshoot per Section 6.
6.
Press the
RESISTANCE
key until you reach Resistance Level 10. Operate the EFX for
another 2–3 minutes.
7.
If the EFX resistance does not change or the operation of the EFX feels inconsistent
compared with Resistance Level 1, troubleshoot per Section 6.
8.
Press the
RESISTANCE
key until you reach Resistance Level 20. Operate the EFX for
another 2–3 minutes.
9.
If the resistance of the EFX does not change or the EFX operation feels inconsistent with
Resistance Levels 1 and 10, troubleshoot per Section 6.
10. Check the LED’s mounted on the upper PCA and the function keys displayed on the
electronic console by performing Procedure 3.2.
11. Press the
CROSSRAMP
key while viewing the electronic console. Confirm that the foot
pads incline and the ramp display increments to 20 as the
CROSSRAMP
key is pressed.
12. Press the
CROSSRAMP
key while viewing the electronic console. Confirm that the foot
pads return to a level position and the ramp display decrements to 1 as the
CROSSRAMP
key is pressed.
13. If the ramp system of the EFX does not operate properly, troubleshoot per Section 6.