GENERAL INSTALLATION 

The following instruction describes the most common type of 

installation for the water heater. However, there are other 

approved methods such as baggage compartment and flush 

mounting. Consult your Field Auditor, Account Manager, or 

the PrecisionTemp Service Department if you have additional 

questions. 

These steps assume the proper location has been determined 

and is being installed at the OEM prior to erecting the walls. 

NOTE: Parts bag that includes corner filler brackets and 

optional water fittings. 

1.

Locate the water heater on the floor of the coach at 

pre-determined location. The unit must be 

permanently supported at the same level as the 

bottom of the sidewall cutout (by the floor or a raised 

floor). 

2.

To install the unit on carpeting, assure the addition of 

metal or wood under the unit is added and extends a 

minimum of three inches beyond the width and depth 

of the appliance enclosure. Minimum clearance 

requirement is zero (except front door for proper 

operation and service). 

3.

If risk of future connection leakage and damage of 

adjacent area is of concern, install a drain pan under 

the unit with drainage to outside of vehicle. 

4.

Connect plumbing to water lines taking care to make 

correct “COLD” and “HOT” orientation. Connect 

3/8” FM flared LP gas line to 3/8” M flared gas 

fitting. 

a.

Allow flexibility in water and gas lines so 

the unit can be pulled through the sidewall 

opening at lease one inch past the skin, 

allowing for sealing step. 

b.

Assure the water and gas line grommets 

continue to be intact and properly inserted in 

the case holes, with no gaps or openings 

where the line passes through the case. 

All connections must be made using TWO 

(2) wrenches to avoid twisting and damaging 

lines. Damage voids the Warranty! 

5.   

Erect the side walls and cut the opening or  

orient the pre-fabricated opening. Frame with  

2” 

x 2” lumber (or equivalent). 

6. 

Pull the unit outward through the opening and bend all  

four flanges outward 90 degrees along the lanced lines. 

Installation 

in water 

heater 

opening 

7. 

To 

prevent 

water leaks

caulk 

thoroughly 

around the  

backside of 

the flanges 

over the 

lanced bend 

slots.  

Caulk the 

perimeter of 

the opening 

(or substitute 

1” x  

3/8” Butyl 

Tape). 

8. 

Push the unit 

to the wall 

against the 

caulking and 

  secure the 

corner brackets behind the unit flanges but   snug to the corner 

of the enclosure. Complete the  

installation by inserting #8 

screws in all the flange   holes. An “air tight” seal must be the 

final result. 

9. 

Place the access door on the lower flange pins aligning  

the holes in the bottom of the door. Carefully close the  

top edge of the door, being careful to align the flue   opening 

with the flue tube and screw in the fastener. 

10.

The appliance must be disconnected from the gas supply 

piping system during any pressure testing of the system 

at test pressures in excess of 

½

 psi. The appliance must 

be isolated from the gas piping system during any 

pressure testing at test pressures equal to or less than 

½

 

psi. Pressure inlet to valve, 13” W.C. maximum, 11” 

W.C. minimum. Pressure at outlet of valve is factory set 

at 10: Burner manifold pressure is W.C. 8.9” W.C. +/- .2”  

           at tap on burner manifold. 

11. 

Turn on the gas and check the water  

heater and all connections for gas leaks  

with 

a leak detecting solution. 

12. 

Turn on water supply line and check for  

Cold In 

Gas Connection 

Hot Out

2

Summary of Contents for cIAPMO-T RV-550

Page 1: ...onal injury or loss of life Installation Operation and Maintenance Effective 3 13 USA and Canada Follow all applicable state and local codes In the absence of local codes or regulations refer to the current standards of Local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 NFPA 54 and or CSA B149 1 Natural Gas and Propane Installation Code Local codes or in the absenc...

Page 2: ... the case holes with no gaps or openings where the line passes through the case All connections must be made using TWO 2 wrenches to avoid twisting and damaging lines Damage voids the Warranty 5 Erect the side walls and cut the opening or orient the pre fabricated opening Frame with 2 x 2 lumber or equivalent 6 Pull the unit outward through the opening and bend all four flanges outward 90 degrees ...

Page 3: ... RELIEF VALVE THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED FOR ANY REASON OTHER THAN REPLACEMENT This water heater is equipped with a pressure relief valve that complies with the standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Systems ANSI Z21 22 CSA 4 4 This valve protects against excessive water expansion only This water heater has separate and dedicated pr...

Page 4: ...e showerhead is turned back on Tests have shown that this will not save water and sometimes uses more water than leaving the shower run continuously Winter Operation and Winterizing Water Heater This heater is equipped with freeze protection that will prevent freezing under most conditions In order for it to function 12 VOLT AND GAS SUPPLY MUST REMAIN TURNED ON This allows the burner to fire and e...

Page 5: ... Pressure Switch 15 Blower Assembly 16 Fan Base 17 Flue Hood Assembly 18 Case Assembly 19 Heat Exchanger 20 ECO 21 Plug 22 Orifice 72 45 000 Btu 23 Orifice 71 50 000 Btu 24 Orifice 027 55 000 Btu 25 Pressure Elbow NS Standard Door Kit Color Req NS Large Door Kit Color Req NS Optional Winter Kit NS Grommet NS NS 22 12 15 Volt Converter 5 1315 2454 1411 1375 1385 1073 3366 2028 3477 3476 3369 3503 3...

Page 6: ...n An open valve can also permit water to bypass heater causing it not to fire There Is No Ignition When Water Is On Power vent is running 1 Be sure the gas valve at the tank is On there is gas in the tank and the gas line is purged of all air 2 Be sure that water flow is at least 0 5 gallon minute 3 Check that the ignition wire is plugged into the spark tower on the ignition control and is not tou...

Page 7: ...r other causes not arising from defects in material workmanship This warranty extends to the original owner of the product only and is subject to the following conditions 1 For a period of two years from the date of purchase PrecisionTemp will replace the complete water heater if the heat exchanger leaks due to corrosion This warranty includes reasonable labor charges required to replace the compl...

Page 8: ... of the unit Locate the pipe out from under the coach while positioning it so that it points about 30 to the rear of the coach Allow for at least 6 to protrude from under the coach Now remove the pipe and coat the inside diameter of the flue pipe elbow with high temperature silicone sealant or equivalent Locate pipe onto tailpiece and screw the elbow of the pipe to the tailpiece This can be done w...

Reviews: