- 4 -
Shelves / Pans / Slides
Fit the shelf / pan slides in the correct position to suit the user.
Gastronorm pans are not supplied as standard.
Castors / Adjustable Legs / Levelling Feet
Lock the two front castors once the cabinet is in its final position by
pressing down the metal bar with your foot. This will stop the
cabinet from moving when the door is opened and closed. The level
on models fitted with castors can
ʼ
t be adjusted so a level floor
should be provided. Models fitted with adjustable legs or levelling
feet can be levelled by screwing the legs/feet in or out to the
desired height.
Initial Start Up
Make sure unit is connected to appropriate power socket. Press and hold standby button
to turn on the
Blast Chiller will automatically go into Chill Store mode.
Checks
After initial startup, the Blast Chiller / Freezer should start to pull down to the preset
temperature, check that the temperature is reducing and listen inside and outside the
cabinet to make sure the fans are turning freely to check there has been no movement in
shipping. If time permits, stay with the cabinet until the preset temperature is reached and
the condensing unit cuts out.
Using Your New Blast Chiller / Freezer
The cabinet must reach its preset operating temperature before loading any produce.
Please ensure that the produce is equally distributed throughout the cabinet and that air
can circulate around and through the products stored.