background image

STICKERS / DECALS

Do not place decals or stickers, especially metal 
decals or stickers on the sensor board, or on the 
stud finder in any place.

DISASSEMBLY / TEFLON PADS

Do not disassemble the stud finder or remove 
the teflon pads that are on the bottom. The stud 
finder will not operate correctly without the 
teflon pads properly in place.  

BATTERIES

The ProFinder 5000 uses 2 AA batteries. Use 
alkaline batteries only; do not use rechargeable 
batteries. Replace both batteries at the  
same time.

REPLACING THE BATTERIES

•  Remove battery cover, 

by sliding the cover to 
the left and lifting. 
Remove batteries and 
dispose of the 
batteries properly. Please recycle.

•  Replace with 2 new AA alkaline batteries.

•  Replace battery cover. Close battery cover  

by sliding the cover to the right until it snaps  
into place.

STORAGE

Store the stud finder in a clean, dry place at 
room temperature. Protect against direct sunlight  
and moisture.

ENVIRONMENTAL CONDITIONS

                               

Storage Temperature

 

 

 0°F to 120°F  
(-18°C to 50°C)         

Operating Temperature

  

 32°F to 110°F  
(0°C to 43°C)           

 

Storage Humidity

 

  0% to 90%  
relative humidity 
(non-condensing)

Operating Humidity

 

 0% to 90%  
relative humidity  
(non-condensing)

DISPOSAL

Stud finders and packaging should be sorted  
for recycling. 

FCC PART 15 CLASS B REGISTRATION  
WARNING

This device complies with Part 15 of FCC rules. 
Operation is subject to the following two 
conditions:
1.  This device may not cause harmful  

interference,  
and

2.  This device must accept any interference 

received, including interference that may  
cause undesired operation. 

TO OPERATE:

•  Hold the stud finder by the handle. Do not 

touch the detector outside of the handle area 
while scanning. 

•  Place the ProFinder 5000 firmly against the 

surface and press the “on” button. Continue to 
hold the “on” button down.  

•  LED lights will immediately display the location 

of any hidden objects. 

 
•  The “on” button may be pressed before or 

after placing the stud finder on the surface to 
be scanned. The stud finder will detect studs 
without sliding the stud finder across the wall, 
but will also operate correctly if it is slid across 
the wall.

•  If more than one hidden object is present, the 

stud finder will show the location of more than 
one hidden object.

•  LED lights indicate the width of  

hidden object(s).

•  On some surfaces it may be helpful to slide 

the stud finder up and down to confirm the 
location of a stud.

 

PRECISION SENSORS PROFINDER 5000 

Congratulations on selecting the most advanced 
wall sensor on the market. Your PRECISION 
SENSORS PROFINDER 5000 incorporates 
advanced technology that precisely senses the 
surface in thirteen locations  
simultaneously, then instantly identifies the 
location(s) of hidden object(s). It is the  
easiest-to-use, fastest, and most accurate stud 
finder on the market.

SAFETY RULES FOR THE PROFINDER 5000

WARNING:

 

Read all instructions before use. 

Failure to follow safety instructions may result  
in electric shock, fire, and/or serious injury  
and death.

SAVE THESE INSTRUCTIONS

WARNING:

 It is possible that there may be 

wood, metal, wiring, or other objects behind the 
surface that are not detected. It is also possible 
that the stud finder may detect pipes, wires, or 
other objects that the user may not want it to 
detect. The stud finder is designed to detect any  
inconsistency without identifying the nature of 
the inconsistency. The stud finder does not 
identify what type of object it detects. The 
illuminated LEDs may indicate the location of 
many different features including, but not limited 
to, studs, beams, water pipes, gas pipes, wires, 
an inconsistency in the surface material or  
paint, etc.

WARNING:

 

TURN OFF

 all gas, water, and 

electric power before using any drilling or 
penetrating devices or equipment including 
drills, saws, routers, hammers, nails, screws, etc.  

WARNING:

 The stud finder alone should not be 

relied upon exclusively to locate objects behind 
a scanned surface. Use other sources of 
information to help locate objects. Other sources 
of information may include, but is not limited to, 
construction plans, visible points of entry of 
pipes, location of switches and outlets, and 
standard 16

"

 and 24

"

 stud spacing practices.

FAILURE TO TAKE THESE AND OTHER  
NECESSARY PRECAUTIONS COULD RESULT 
IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS 
INJURY AND DEATH.

Clean

Before turning on, ensure that the stud finder is 
clean and dry. If necessary, wipe the stud finder 
dry using a clean cloth. If the detector is wet or 
dirty it may not operate properly.

Temperature

If the stud finder is subject to a significant 
temperature change, allow it adjust to the 
ambient temperature before using. The entire 
area of the sensor board should be at a similar 
temperature for best operation.

IMPORTANT: READ BEFORE USING. 
SAVE THESE INSTRUCTIONS.

 

 

Operating/Safety Instructions

1.  LED Lights
2.  Ergonomic Handle
3.  “On” Button 
4.  Battery Cover
5.  Detector Housing
6.  Sensor Board

OPERATING INSTRUCTIONS

1

2

3

4

6

5

SENSING THROUGH DIFFERENT MATERIALS:

 

Moisture

The scanned surface should be clean and dry. 
Paint and wallpaper need to be completely dry 
before scanning for studs. It may take up to  
2 weeks for wallpaper to dry enough to  
detect studs.

Curved Surfaces

There is a minor degree of curvature in the walls 
of most homes and buildings. The curvature is 
small enough that it may not be noticed. The 
ProFinder 5000 can detect objects through 
curved surfaces because the ProFinder 5000 has 
a sensor board that bends slightly to match the 
contour of most walls. Press the stud finder firmly 
against the surface and the sensor board will 
match the contour of the surface, and provide 
the best reading.

Foil-Backed Insulation

  

Although foil covered insulation is not very 
common, metal foil can cause inconsistent 
readings with all electronic stud finders, 
including the ProFinder 5000.

Metallic Content in Wallpape

r

Wallpaper with metallic content can block the 
detector’s signals. 

Textured Walls and Acoustic Ceilings

The ProFinder 5000 is capable of detecting studs 
through many textured surfaces. The stud finder 
should be placed firmly against the surface for 
best results. 

Lath and Plaster

Irregularities in plaster thickness and variations in 
construction materials can make it difficult to 
locate studs behind lath and plaster walls. Also, 
if the plaster has a mesh reinforcement, the stud 
finder may not be able to detect through the 
metal mesh. Although many users have success 
with the ProFinder 5000 on lath and plaster 
walls, there is no guarantee the ProFinder 5000 
will work on all lath and plaster walls.

Tile, Flooring, Roofing, and on the Outside  
of the House

The ProFinder 5000 works by measuring the 
density of material behind the sensors to 
determine the location of studs. Due to the 
variability in the density of materials in tile, 
flooring, roofing, and on the outside of the 
house, we do not recommend the ProFinder 
5000 for use in these applications.

WARRANTY

Precision Sensors warrants this product to be 
free from defects in material and workmanship 
for one year. This LIMITED WARRANTY does not 
cover products that are improperly used, abused, 
or altered. Defective products will be replaced or 
repaired. If a product is found to be defective 
within the warranty period, Precision Sensors will,  
at its sole discretion, either repair or replace the 
defective product. This limited warranty does not 
apply to products that are subjected to freight 
damage, accident, abuse, alteration, misuse, 
improper repair, etc. Precision Sensors and 
Precision Sensors’ authorized distributors shall 
bear no other liability or obligation under  
this warranty. 

Precision Sensors does not authorize any person  
or representative to assume or grant any other 
warranty or obligation with the sale of this 
product. Precision Sensors’ limited warranty is 
valid only if you retain proof of purchase from 
Precision Sensors or a Precision Sensors 
authorized dealer for this product. If you 
purchase this product from any other source, 
your purchase is “AS IS,” which means Precision 
Sensors grants you no warranty, and that you, 
not Precision Sensors, assume the entire risk of 
the quality and performance of this product. The 
warranty period for any replaced and/or repaired 
part under this warranty shall expire at the end of 
the original warranty period.

ALL EXPRESS AND IMPLIED WARRANTIES FOR 
THIS PRODUCT, ARE LIMITED IN DURATION TO 
THE WARRANTY PERIOD, AND NO  
WARRANTIES, WHETHER EXPRESS OR 
IMPLIED, WILL APPLY AFTER THIS PERIOD. THIS 
WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL 
OTHER OBLIGATIONS, LIABILITIES OR 
WARRANTIES. In no event shall Precision 
Sensors or its licensed distributors be liable or  
responsible for INCIDENTAL OR  
CONSEQUENTIAL DAMAGES or for any other 
direct or indirect damage, loss, cost, expense or 
fee. Some states do not allow the exclusion or 
limitation of incidental or consequential 
damages, so this exclusion or limitation may not 
apply to you. This warranty gives you specific 
legal rights and you may also have other rights 
that vary from state to state. 

US Patents 8,476,912 8,593,163 8,669,772
US and Foreign Patents Pending

Rev. C2

TROUBLE SHOOTING

TROUBLESHOOTING

CONDITION

PROBABLE CAUSE

SOLUTION

No LED lights come on.

Weak battery.

Replace with 2 new AA alkaline batteries.

Stud finder only works momentarily.

The “on” button isn’t being held down.

Hold the “on” button down until you have completed your scan.

The LED lights are indicating the location of pipes 

and wires, not just studs.

The ProFinder 5000 indicates the location of inconsistencies. The 

LED lights may indicate the location of a pipe, electrical wiring, 

other objects near the surface being scanned, or an inconsistency 

in the surface material or paint, etc.

Look for evenly placed studs on either side (16

"

, 24

"

, on center, etc.) Scan 

above the location and below the location to confirm results. Use caution 

before penetrating wall. See the SAFETY RULES FOR THE PROFINDER 5000.

Difficulty starting a scan near doors and windows.

Double studs, triple studs and solid headers are often present 

around doors and windows. The stud finder requires the presence 

of a region without studs to correctly identify studs.

Begin the scan away from the window or door, then move the stud finder to the 

area around the window or door. For best results, keep stud finder 3" away from 

wood trim, outlets, switches, etc.

Stud finder doesn’t work through new wall paper.

The moisture in the wall after wall papering can block the stud 

finder’s signal.

Wait until the wallpaper is dry. It may take up to 2 weeks for the paper to dry 

sufficiently.

My house was built prior to about 1960. The walls 

are lath and plaster. The stud finder doesn’t work 

very well anywhere in my house.

Older houses that were built with lath and plaster, instead of 

sheet rock, often have too much inconsistency in the walls for the 

detector to work reliably.

Try using the stud finder at a higher point on the wall, or a lower point on  

the wall.

Inconsistent readings.

Curved surface.

Anomaly in the surface material.

Press the stud finder firmly against the wall so that the contour of the sensor 

board matches the slight contour of the wall.

Test at a higher location, or lower location on the wall.

Sometimes after scanning the wall for a period of time the 

readings seem to be less consistent.

Release the button and press the button again.

When I put my hand in front of the sensor board, 

the readings are not what I would expect.

The stud finder is designed for detecting features in walls,  

not hands.

Place the stud finder on the wall to detect hidden features.

The LED lights sometimes seem to light up  

sporadically or inconsistently.

Wires, pipes, or other construction inconsistencies can cause 

erratic or erroneous readings. Features on the opposite side of a 

wall may also be a source of  

inconsistent readings.

Test at points on the wall that are higher, or lower. The stud finder may also 

work best if it is used more than 3 inches away from metal objects such as 

outlets, light switches, etc.

Reviews:

Related manuals for Profinder 5000