Warnings and Cautions  

  

WARNING  

Oxygen supplied from this device is for supplemental use and is not intended to be life supporting or life sustaining.   
This device is not intended for use by patients who would suffer immediate, permanent, or serious health consequences 
as a result of an interruption in the oxygen supply.  
  

 

This device is NOT to be used by patients who breathe through their mouths.  

 

DO NOT smoke in an area where oxygen is being administered.  

 

DO NOT use near any type of flame or flammable/explosive substances, vapors or atmosphere.  

 

DO NOT use oils, greases, lubricants or any combustible materials on or near this product. Wash hands properly 
prior to usage.  

  

TO AVOID INCREASED RISK OF FIRE  

 

Keep oxygen equipment away from open flames. Use and store the POC at least five (5) feet away from 
equipment such as furnaces, water heaters, and stoves that may contain open flames.  

 

Keep equipment in a well-ventilated area at all times.  

 

High concentrations of oxygen can cause rapid burning of other substances.  

 

DO NOT place blankets, draperies, or other fabrics over equipment.  

 

DO NOT use if dirt or contaminants are present on or around fill connectors on the POC.  

 

NO OXYGEN is delivered when the Pulse Selector is at the “Off” Setting.  

 

NO OXYGEN is delivered in between settings.  

 

DO NOT use while sleeping without consulting your Equipment provider.  

 

CAUTION  

 

This device is designed to operate with a single lumen, adult, nasal cannula with a maximum length  of 7 feet or 
less.  

 

Only individuals instructed and trained in its use should operate this device. 

 

Inspiratory efforts vary from patient to patient. The POC may not be able to detect respiratory efforts of all 
patients.  

 

This device contains magnetic, ferrous material that may affect the results of an MRI.  

 

DO NOT use liquid leak detector to test for leaks.  

 

DO NOT autoclave.  

 

DO NOT gas sterilize.  

 

DO NOT clean with aromatic hydrocarbons.  

 

DO NOT immerse device in any kind of liquid.  

 

Avoid dropping the device or placing it in a position where it could fall and become damaged.  

 

DO NOT block the outlet fitting or kink the cannula tubing when the device is in use.  

 

Store device in a clean area when not in use.  

 

Only use the Precision Medical carrying bag or carrying bag/backpack that is supplied from Precision Medical with 
the POC.   

 
 

Summary of Contents for EASY PULSE PM4150 SERIES

Page 1: ...Service Manual Model PM4150 Series Precision Medical Inc 300 Held Drive Northampton PA 18067 USA 507719 Rev 1 051414...

Page 2: ...posal Instructions 7 Troubleshooting 8 Alarm Indicators 9 Sieve Bed Assembly Replacement 505849 10 Disassembly 10 Reassembly 11 Control Panel Replacement 505845 12 Disassembly 12 Reassembly 13 PC Boar...

Page 3: ...d its inherent dangers DO NOT attempt to use or perform any service function on the PM4100 series POC unless you have read and understand this manual as well as the User Manual Definition of terms POC...

Page 4: ...a very short duration of time 0 2 to 0 4 seconds It also controls the delivered minute volume which remains consistent between 15 and 35 BPM The total oxygen volume delivered minute volume the patien...

Page 5: ...draperies or other fabrics over equipment DO NOT use if dirt or contaminants are present on or around fill connectors on the POC NO OXYGEN is delivered when the Pulse Selector is at the Off Setting NO...

Page 6: ...g 1 4 5 hrs Approximate Setting 2 3 2 hrs Setting 3 2 5 hrs Setting 4 1 8 hrs Setting 5 1 5 hrs Sound Setting 2 44 dBA Cannula Maximum 7 ft 2 1 m long standard adult single lumen nasal cannula Equipme...

Page 7: ...5 P a g e Component Description External...

Page 8: ...6 P a g e Internal...

Page 9: ...n a clean area free from grease oil and other sources of contamination Inlet Filter 1 Remove the inlet filter by pulling on the protruding tab 2 Wash filter with mild detergent Rinse thoroughly with w...

Page 10: ...change to alternate oxygen source and contact your Equipment Provider Red alarm indicator is illuminated device is not running and setting numbers 1 3 are flashing Repetitive beep Internal battery is...

Page 11: ...9 P a g e Alarm Indicators Green Ready for use Amber Caution Prompt response by the OPERATOR is required Red Warning Immediate response by the OPERATOR is required...

Page 12: ...er by lifting up and off the Sieve Bed Assembly set it aside as shown 6 Stand the POC up Remove the tubing clip from the right large Sieve Bed Tube as shown below 7 Using diagonal cutters carefully cu...

Page 13: ...Sieve Bed Assembly are pointing away from one another 4 Set the Sieve Bed Assembly into position 5 Attach the large Tubes to the Sieve Bed Assembly left Tube to the left Elbow right Tube to the right...

Page 14: ...down and out of the way 8 Using diagonal cutters carefully cut the Cable Tie securing the small Tube to the PC Board as shown below and discard the used Cable Tie 9 Disconnect the small Tube from the...

Page 15: ...Ribbon Cables can be connected 6 Using needle nose pliers gently grasp the narrow Ribbon Cable and slide into its corresponding Connector on the PC Board Secure the Ribbon Cable in place by pushing th...

Page 16: ...d Replacement in this manual NOTICE The correct Firmware must be installed for the device to operate correctly Compressor Motor 505852 has been replaced with new Compressor Motor 507640 If Motor PN 50...

Page 17: ...Disassembly section of the Control Panel Replacement in this manual 3 Remove the 4 Screws securing Pump Compartment Cover and set aside 4 Using diagonal cutters cut the Cable Tie that secures the lar...

Page 18: ...e 8 Start to secure a Cable Tie and slide it over the large rear Tube on the pump 9 Position the Pump Fan assembly into the POC by sliding it into its corresponding slot 10 Using needle nose pliers co...

Page 19: ...of the Reassembly section of the Internal Battery Replacement in this manual 2 Follow steps 2 thru 12 of the Reassembly section of the Sieve Bed Replacement in this manual NOTICE The correct Firmware...

Page 20: ...seconds 4 Then like a combination lock turn dial to 5 then 1 then 3 then off 5 Turn device to any flow setting Device will continuously pulse 6 The alarm LED on the front will blink yellow and red wh...

Reviews: