™ PD6402 High Voltage & mV to Current Meter
Instruction Manual
20
Display Functions & Messages
The meter displays various functions and messages
during setup, programming, and operation. The
following table shows the main menu functions and
messages in the order they appear in the menu.
Display Functions & Messages
Display
Parameter
Action/Setting
Description
setup
Setup
Enter
Setup
menu
units
Unit
Select the display
units/tags
Ch-A
*
Unit
Set unit or tag for channel
A (*or V or P)
Dec pt
Decimal
point
Set decimal point
Ch-A
*
Decimal
point
Set decimal point for
channel A (*or V or P)
InCAL
Input
calibration
Enter the
Input Calibration
menu
Ch-A
*
Input A
Set input type for channel
A (*or V)
SCAL A
Scale A
Enter the
Scale
menu for
channel A
Inp 1
Input 1
Scale input 1 signal or
program input 1 value
Dis 1
Display 1
Program display 1 value
Inp 2
Input 2
Scale input 2 signal or
program input 2 value (up
to 32 points)
Dis 2
Display 2
Program display 2 value
(up to 32 points)
Error
Error
Error, scaling not
successful, check signal or
programmed value
Cal A
Calibrate A
Enter the
Calibration
menu
for channel A
Inp 1
Input 1
Calibrate input 1 signal or
program input 1 value
Dis 1
Display 1
Program display 1 value
Inp 2
Input 2
Calibrate input 2 signal or
program input 2 value (up
to 32 points)
Dis 2
Display 2
Program display 2 value
(up to 32 points)
Error
Error
Error, calibration not
successful, check signal or
programmed value
dsplay
Display
Enter the
Display
menu
Line 1
Line 1
Assign the upper display
parameter
Line 2
Line 2
Assign the lower display
parameter
D Ch-A
Display Ch-
A
Assign display to channel
A
D Ch-V
Display Ch-
V
Assign display to channel
V
D Ch-P
Display Ch-
P
Assign display to channel
P (P=A*V)
D AV
Display AV
Alternate display of
channel A & V
D Ap
Display AP
Alternate display of
channel A & P
Display Functions & Messages
Display
Parameter
Action/Setting
Description
D Vp
Display VP
Alternate display of
channel V & P
D AVp
Display AVP
Alternate display of
channel A, V, & P
D set1
*
Display set
1*
Displays relay 1 (*through
8) set point.
D Hi-A
Display high
A
Display high value of
channel A
D Lo-A
Display low
A
Display low value of
channel A
D HL-A
Display
hi/low A
Alternate between high/low
value of channel A
D Hi-V
Display high
V
Display high value of
channel V
D Lo-V
Display low
V
Display low value of
channel V
D HL-V
Display
high/low V
Alternate between high/low
value of channel V
D Hi-p
Display high
P
Display high value of
channel P
D Lo-p
Display low
P
Display low value of
channel P
D HL-p
Display
high/low P
Alternate between high/low
value of channel P
D a-u
Display A
and
units/tags
Alternate display of
channel A and the unit/tag
D V-u
Display V
and
units/tags
Alternate display of
channel V and the unit/tag
D p-u
Display P
and
units/tags
Alternate display of
channel P and the unit/tag
nm bus
Display
Modbus
Display Modbus input
register
D off
*
Display off
Display blank display (*line
2 only)
D unit
*
Display unit
Display line 1 channel units
(*line 2 only)
d-Inty
Display
intensity
Set display intensity level
from 1 to 8
RELaY
Relay
Enter the
Relay
menu
Assign
Assignment
Assign relays to channels
or Modbus
Asign1
*
Assign 1*
Relay 1 (*through 8)
assignment
Ch-A
*
Channel A*
Assign relay to channel A
(*or V or P)
nm bus
Modbus
Assign relay to Modbus
register
RLY 1
*
Relay 1*
Relay 1 (*through 8) setup
Act 1
*
Action 1*
Set relay 1 (*through 8)
action
Auto
Automatic
Set relay for automatic
reset
A-nman
Auto-manual
Set relay for auto or
manual reset any time
LatCH
Latching
Set relay for latching
operation