ProtEX-MAX PD8-6310-WM Explosion-Proof NTEP Certified Batch Controller Instruction Manual
6
Ordering Information
85-265 VAC Model
12-24 VDC Model
Options Installed
PD8-6310-6H7-WM
PD8-6310-7H7-WM
4 relays & 4-20 mA output
Accessories
Model
Description
PDA1232
RS-232 P
RO
V
U
serial adapter
PDA1485
RS-485 P
RO
V
U
serial adapter serial adapter
PDA7485-I
RS-232 to RS-422/485 isolated converter
PDA8232-N
USB to RS-232 non-isolated converter
PDA8485-I
USB to RS-422/485 isolated converter
PDA2811
1 Meter Plastic NEMA 4X Enclosure
PDA2812
2 Meter Plastic NEMA 4X Enclosure
PDX6901
Suppressor (snubber): 0.01 µF/470
, 250 VAC
Specifications
Except where noted all specifications apply to operation at +25°C.
General
Display
Line 1: 0.6" (15 mm) high, red LEDs
Line 2: 0.46" (12 mm) high, red LEDs
6 digits: each (-99999 to 999999), with lead
zero blanking.
Default
Display
Assignment
The Upper display shows batch total. The
Lower display shows rate with alternating
units, and can be switched to show grand
total, batch count, or preset with the STOP
key.
Custom
Display
Assignment
The Upper and Lower displays may be
assigned to rate, total, grand total, batch
count, preset, set points, units (lower
display only), alternating R & T, R & GT,
preset & rate, max & min, or a Modbus
display register. Any rate/total/grand total
display may be programmed to alternate
with a custom unit or tag.
Alternating
Display
Displays alternate every 10 seconds when
display is selected or the batch is paused.
Display
Intensity
Eight user selectable intensity levels
Display
Update Rate
5/second (200 ms)
Overrange
Display flashes
999999
Underrange
Display flashes
-99999
Front Panel
NEMA 4X, IP65
Programming
Methods
Four front panel buttons, digital inputs, PC
and MeterView Pro software, or cloning
using Copy function.
Programming
Lockout
Programming lockout jumper. Seal loop and
loop attachment features to prevent access
to the lockout jumper.
Recalibration
All ranges are calibrated at the factory.
Recalibration is recommended at least
every 12 months.
Max/Min
Display
Max/min readings reached by the process
are stored until reset by the user or until
power to the controller is cycled.
Password
Three programmable passwords restrict
modification of programmed settings and
two prevent resetting the totals.
Pass 1: Allows use of function keys and
digital inputs
Pass 2: Allows use of function keys, digital
inputs and editing set/reset points
Pass 3: Restricts all programming, function
keys, and digital inputs.
Total Password: Prevents resetting the total
manually
Gtotal Password: Prevents resetting the
grand total manually
Non-Volatile
Memory
All programmed settings are stored in non-
volatile memory for a minimum of ten years
if power is lost.
Power
Options
85-265 VAC 50/60 Hz, 90-265 VDC, 20 W
max or 12-24 VDC
10%, 15 W max
Powered over USB for configuration only
Fuse
Required external fuse: UL Recognized, 5
A max, slow blow; up to 6 controllers may
share one 5 A fuse
Isolated
Transmitter
Power Supply
Terminals P+ & P-: 24 VDC
10%. selectable
for 24, 10, or 5VDC supply (internal jumper J4).
All models transmitter supply rated @ 25mA
max.
Normal Mode
Rejection
Greater than 60 dB at 50/60 Hz
Isolation
4 kV input/output-to-power line
500 V input-to-output or output-to-P+ supply