background image

PD2-6400

  Helios High Voltage & Current Meter

www.predig.com

11

0-5 AAC

Transformer

Lighting System

0-5 AAC

A

Generator (120 VAC)

Load

+

120 VAC

2

5

V

Voltage/Current Input Application Example

Voltage/Current Input Wiring Example  

with AC Switch Selected

Model PD6400 High Voltage & Current Meter

Instruction Manual

20

Figure 9. DC Voltage Input Connections

Current Input

The following figures show examples of connecting the meter for a current 

input. Note that in addition to the connections, the AC/DC type switch 

much also be set.

Figure 10. AC Current Connections

Figure 11. AC Current Transformer Connections

Model PD6400 High Voltage & Current Meter

Instruction Manual

22

Figure 14. AC Current Transformer and Voltage Connections

Figure 15. DC Current and Voltage Connections

Apparent Power Measurement Using a Current Transformer

Current Measurement for a Lighting System 

APPLICATION EXAMPLES

The PD2-6400 Helios can be used to display application data for voltage, current, or both. Each Channel, Voltage or Current, can 

be scaled independently.  The following examples show just a few of the PD2-6400’s application capabilities using generators 

and transformers.  Each example is followed by a wiring diagram that shows proper switch position for the meter.

Voltage Input Application Example

Voltage Input Wiring Example 

with AC Switch Selected

Model PD6400 High Voltage & Current Meter

Instruction Manual

19

Power Connections

Power connections are made to a two-terminal connector labeled 

POWER on Figure 6. The meter will operate regardless of DC polarity 

connection. The + and - symbols are only a suggested wiring convention.

Figure 7. Power Connections 

Signal Connections

Signal connections are made to a four-terminal connector labeled 

SIGNAL on Figure 6. The I+ and I- terminals are used for Channel A 

(CH-A) as the current input terminals. The V+ and V- terminals are used 

for Channel V (CH-V) as the voltage input terminals.
In addition to the signal connections, the switch labeled TYPE on Figure 

6 must be set to AC (alternating current) or DC (direct current) to accept 

the corresponding type of voltage and current signals.

Voltage Input

The following figures show examples of connecting the meter for a 

voltage input. Note that in addition to the connections, the AC/DC type 

switch much also be set.

Figure 8. AC Voltage Input Connection

AC or DC

POWER

Required External Fuse:

5 A max, 250 V Slow Blow

POWER

+ -

Voltage Measurement for a Generator Driving a Load 

Current Input Wiring Example

with AC Switch Selected

Current Input Application Example

Load

120 VAC @

700 AAC

0-5 AAC

Current

Transformer

2

5

A

V

Summary of Contents for Helios PD2-6400

Page 1: ...Programming Software Super Bright Display Operating Temperature Range 40 to 65 C 40 to 150 F UL C UL Listed E160849 508 Industrial Control Equipment Input Power Options Include 85 265 VAC or 12 24 VD...

Page 2: ...ANCED DISPLAY FEATURES 4 QUICK EASY SCALE PROGRAMMING METHODS 5 4 20 MA OUTPUT RELAYS 8 APPLICATION EXAMPLES 11 DIGITAL COMMUNICATIONS 13 ON BOARD DIGITAL INPUTS AND OUTPUTS 13 PHYSICAL FEATURES 14 OP...

Page 3: ...ally all these features and capabilities can easily be programmed with free MeterView Pro PC based software Precision Digital also offers several accessories for the Helios to enhance the user experie...

Page 4: ...urrently set to 95 00 Display Voltage and Current Individually or at Same Time The Helios PD2 6400 can accept both a voltage and a current input These can be displayed as one or the other as illustrat...

Page 5: ...ompleted it can be locked with a password Free PC Based MeterView Pro USB Programming Software Cable The Helios comes preloaded with free MeterView Pro programming software that connects and installs...

Page 6: ...eters Set Analog Output Values Enable Manual Control Test Relays Digital Outputs Setup Screen Set Scale Values Set the Number of Points up to 32 Import from Excel Export to Excel Programming Screen Gr...

Page 7: ...10 Communications Onboard USB firmware version 4 0 or higher RS 232 Adapter or RS 485 Adapter Meter Address 1 247 Reports Data logging Save as CSV file format Configuration Save as PDC file format or...

Page 8: ...set up for reverse scaling as shown below the output will be 4 00 mA when the display reads 150 0 and the output will be 20 00 mA when the display reads 0 Front Panel Push Button Programming The 4 20...

Page 9: ...inals F4 and Common Latching Alarm must be reset manually and can be done so at any time with a switch wired across terminals F4 and Common Latching with Reset after Cleared Alarm must be reset manual...

Page 10: ...en the PV reaches that set point it will close that relay s contacts for a preset period of time 0 1 to 5999 9 seconds Switching Inductive Loads The use of suppressors snubbers is strongly recommended...

Page 11: ...few of the PD2 6400 s application capabilities using generators and transformers Each example is followed by a wiring diagram that shows proper switch position for the meter Voltage Input Application...

Page 12: ...vailable in ranges of 100 200 400 600 and 1000 AAC These nonintrusive devices feature split core convenience for easy installation and are a cost effective solution for monitoring load or proof of ope...

Page 13: ...ers click here PDA7485 I RS 232 to RS 422 485 Isolated Converter PDA8485 I USB to RS 422 485 Isolated Converter All adapters and connectors supplied with appropriate cables Modbus PV Input Remote Mess...

Page 14: ...in industrial applications where it will be exposed to wet dusty hot cold and other adverse conditions The Helios is housed in a rugged NEMA 4X enclosure can operate over a wide temperature range incl...

Page 15: ...e Range The Helios can operate from 40 to 65 C 40 to 150 F meaning it can be installed in a wide variety of indoor and outdoor industrial applications And over this range the Helios will drift no more...

Page 16: ...nal for Digital Input Remote Operation of Front Panel Buttons The Helios s programming buttons are located behind a door and generally not accessible during operation Digital inputs are provided that...

Page 17: ...rol or to return them to automatic operation Click here to watch the Meterview Pro video Custom Tags i e Power Custom Units i e Amps Volts Alarm Status Indicators Plastic Control Stations For The Heli...

Page 18: ...nue to be calculated in the background FK DI Ln1 Hi Display maximum display value on line 1 FK DI Ln1 Lo Display minimum display value on line 1 FK DI Ln1 HL Display maximum minimum display values on...

Page 19: ...V F4 COM 2 1 4 3 2 1 I I AC TYPE DC CONNECTIONS Connector Labeling for Fully Loaded PD2 6400 DIMENSIONS Mounting Hole Mounting Hole Connection Cover Screw 10 63 270 12 59 319 7 2 63 67 4 77 121 2 2600...

Page 20: ...d Enclosure Operating Temperature of 40 to 65 C Now UL and C UL Approved LARGE DISPLAYS Helios Series IECEx Big Bright Displays For Indoor or Outdoor in Bright Sunlight 24 VDC Transmitter Power Supply...

Page 21: ...plastic case color gray Includes four PG11 through hole conduit openings with two factory installed PG11 IP68 black nylon threaded hole plugs with backing nuts Wall Mounting Four 4 mounting holes prov...

Page 22: ...r none with 1 or 2 stop bits Byte to Byte Timeout 0 01 2 54 seconds Turn Around Delay Less than 2 ms fixed Note Refer to the HeliosRegister Tables located at www predig com for details Isolated 4 20 m...

Page 23: ...mation contained in this document is subject to change without notice Precision Digital Corporation makes no representations or warranties with respect to the contents hereof and specifically disclaim...

Reviews: