PD2-6300
Helios Large Display Pulse Input Rate/Totalizer Instruction Manual
47
Advanced Features Menu
To simplify the setup process, functions not needed for most applications are located in the
Advanced
Features
menu.
Press and hold the Menu button for three seconds to access the advanced features of the meter.
Advanced Features Menu & Display Messages
The following table shows the functions and messages of the
Advanced Features
menu in the order they
appear in the menu.
Display
Parameter
Action/Setting
Gate
Gate
Enter Gate function menu
Lo G
Low gate
Program Low gate value
Hi G
High gate
Program High gate value
filtEr
Filter
Set noise filter value
Lo Spd
Low speed
Set the contact de-bounce filter value
Hi Spd
High speed
Select high speed filter
Round
Round
Set the rounding value for display variables
seriAl
Serial
Set serial communication parameters
SlaveId
Slave ID
Set slave ID or meter address
baud
Baud rate
Select baud rate
Tr dLY
Transmit delay
Set transmit delay for serial communication
Parity
Parity
Select parity: Even, Odd, or None with 1 or 2 stop bits
t-byt
Time byte
Set byte-to-byte timeout
SelEct
Select
Enter the Select menu (function, cutoff, out)
Functn
Signal input
conditioning
Select linear, square root, programmable exponent, or round
horizontal tank function
Linear
Linear
Set meter for linear function and select number of linearization
points
No PtS
Number of points
Set PV1 for 2 to 32-point linearization
Set PV2 for 2 to 8-point linearization