Helios PD2-6080/PD2-6081 Modbus
®
Scanners
Instruction Manual
38
Setting Up the Displays
(
dsplay setup
)
Display Line 1 Parameters
(
Line 1 dsplay
)
The top display (
line 1
) can be programmed to
display any of the following:
Display
Parameter
Setting Description
D pV
Display PV
Display PVs 1-16
D Ch-C
Display C Channel
Display Math Channels
C1-C4
PV.unit
Display PV & Units
Display PV & Units
Tg.pVn
Display Tag,
PV Number
Display Tag & PV
Number selected
Tg.pVn.u
Display Tag,
PV# & Units
Display Tag, PV Number
selected, & Units
C.unit
Display C & Units
Display C1-C4 & Units
Tg. C. u
Display Tag, C,
& Units
Display Tag, C1-C4 &
Units
Dset 1
Display Set Points
1-4
Display Set Points 1-4
Hi-pV
Display Max
PV 1-16
Display Maximum value
for each enabled PV1-16
Lo-pV
Display Min
PV 1-16
Display Minimum value
for each enabled PV1-16
Hi-C
Display Max
Ch C1-C4
Display Maximum for
math channels C1-C4
Lo-C
Display Min
Ch C1-C4
Display Minimum for math
channels C1-C4
Display Line 2 Parameters
(
Line 2 dsplay
)
The bottom display (
line 2
) can be programmed to
display any of the following:
Display
Parameter
Setting Description
D pV
Display PV
Display PVs 1-16
D Ch-C
Display C
Channel
Display Math Channels
C1-C4
PV.unit
Display PV &
Units
Display PV & Units
Tg.pVn
Display Tag,
PV Number
Display Tag & PV
Number selected
Tg.pVn.u
Display Tag,
PV# & Units
Display Tag, PV Number
selected, & Units
C.unit
Display C & Units
Display C1-C4 & Units
Tg. C. u
Display Tag, C,
& Units
Display Tag, C1-C4 &
Units
Dset 1
Display Set Points
1-4
Display Set Points 1-4
Hi-pV
Display Max
PV 1-16
Display Maximum value
for each enabled PV1-16
Lo-pV
Display Min
PV 1-16
Display Minimum value
for each enabled PV1-16
Hi-C
Display Max
Ch C1-C4
Display Maximum for
math channels C1-C4
Lo-C
Display Min
Ch C1-C4
Display Minimum for math
channels C1-C4
D tag
Display Tag
Display Tag (Line 2 only)
D tag.u
Display Tag &
Units
Display Tag & Units
(Line 2 only)
D off
Display off
Display Off (Line 2 only)
Note: Toggling displays use the Scan Time for the
value and 2 seconds for Tag and Units.
Display Intensity (
d-IntY
)
The scanner has eight display intensity levels to give
the best performance under various lighting
conditions. Select intensity 8 for outdoor applications.
The default intensity setting is 6.