415 N. Maple Grove Boise, ID 83704
www.PreciseMRM.com
3710024B
Support: (888) 254-1634
Copyright 2009
Sales: (888) 449-0357
p. 14 of 16
Power
Parameter
Rating
Units
Supply voltage
Operating
9.8 to 32.0
V
Continuous
65.0
V (max)
Over-voltage protection threshold (Note 1) 40
V (min)
48
V (max)
Input current (average)
Vin=24V dc Sleep
15
mA (typ)
Operating
90
mA (typ)
Vin=12V dc Sleep
20
mA (typ)
Operating
160
mA (typ)
1. Above this threshold, device will not operate until voltage is within normal operating
range
Inputs
Parameter
Rating
Units
High Level Input
5.0
V (min)
36.0
V (max)
Low Level Input
0.8
V (max)
-0.8
V (min)
Physical
Parameter
Rating
Units
Dimensions
4.7 x 5.3 x 1.5
in
120 x 135 x 38
mm
Weight
0.6
lbs
0.3
kg
Environmental
Parameter
Rating
Operating Temperature:
-30°C to +60°C
Storage Temperature:
-40°C to +85°C
Humidity:
5% to 95% RH non-condensing at +40°C
Vibration:
SAE J1455 for chassis-mounted devices (4g, 20Hz-2kHz).
Shock:
±25g
Electrical Protection:
SAE 1455 (12V & 24V)
load dump
inductive switching
mutual
±8kV ESD, human body model
Reverse polarity
Over-voltage shutdown