Clean the front transparent cover at least every 6 months. Use a moist,
lint-free cloth. Never use alcohol or solvents.
A scheduled maintenance programme must be carried out on the
installation and the fittings regardless of their IP rating or application –
these must include the following operations:
●
Clean the fittings from dirt that may be deposited in the heads of the
screws by following the installation instructions attached to each
fitting.
●
Check that the screws are not loose on the various components of
the luminaire (glass frame, cable entry , ...).
●
Check each cable gland, and cable for damage and that the cable
gland has not come loose.
●
For each Isolation Class 1 fitting check that the earth cable has not
come loose. The clip must not show signs of oxidation,damage or
become loose.
●
For class 2 fittings check any eventual plastic / isolating covering in
order to verify any damage.
●
Check that all the seals are in good condition and that they are not
damaged or split.
The internal components such as the ballasts, transformers, washers
and screws must not show clear signs of oxidation or rust.
Clear traces of rust and oxidation will indicate the presence of water
inside the luminaire.
In case of damage the components must be replaced by original
components and spare parts before using the fitting.
We also recommend to check the fitting at least once a year or within
the prescribed maintenance schedule period depending on the type of
installation.