background image

INGROUND LINEAR

Lenght = 650/950/1250

INSTRUCTIONS MANUAL

ON/OFF or DALI

Summary of Contents for INGROUND LINEAR

Page 1: ...INGROUND LINEAR Lenght 650 950 1250 INSTRUCTIONS MANUAL ON OFF or DALI...

Page 2: ...ATION 3 INSTALLATION 4 CONNECTION DIAGRAMS 5 CARE AND MAINTENANCE 6 TECHNICAL SPECIFICATION 7 WARRANTY STATEMENT 2 4 5 10 12 13 14 FOR YOUR OWN SAFETY PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEF...

Page 3: ...pecific lighting systems including TRIDONIC drivers Using precision manufacturing techniques the INGROUND LINEAR provides professional solutions for your lighting requirements Also it has a passive co...

Page 4: ...CTION INGROUND LINEAR INSTRUCTIONS MANUAL v1 1 3 Lenght 650 mm 1 2 Dimensions Lenght 950 mm Lenght 1250 mm 611 630 640 650 95 108 100 950 911 932 942 1250 1211 1232 1242 108 95 100 108 100 95 WWW PREC...

Page 5: ...only by a qualified person The light fixture must be wired according to respective electrical standards The manufacturer shall not be liable for any modifications of the product of incorrect installa...

Page 6: ...OK Prepare always 20 30 cm of drainage gravel and check that it works fill the tube of water and check that it completely disappear within 30 min If it doesn t work study a further drainage system Al...

Page 7: ...e we fixed the fixture Never cover visible parts of the fittings Any part not protected by the recessing box must not be in direct contact with the ground or in contact with aggressive chemical elemen...

Page 8: ...3 INSTALLATION INGROUND LINEAR INSTRUCTIONS MANUAL v1 1 7 3 2 1 Wiring ON OFF option 3 2 Connection L N PE Wire L Live black brown Wire N Neutral blue Wire PE Earth yellow green WWW PRECILUM COM...

Page 9: ...ND LINEAR INSTRUCTIONS MANUAL v1 1 8 3 2 2 Wiring DALI option 3 2 Connection L N PE DALI DALI Wire L Live black brown Wire N Neutral blue Wire PE Earth yellow green Wire DA1 Dali white Wire DA2 Dali w...

Page 10: ...sealing junction boxes containing electrical connections If the IP rating of the connection is not observed the complaint will not be accepted For example https www etelec com prodotto mpgel Video tut...

Page 11: ...ONNECTION DIAGRAMS INGROUND LINEAR INSTRUCTIONS MANUAL v1 1 10 4 1 ON OFF option Junction box 230V 3 x 1 5 mm Must be specified by the electrical designer Notation Luminaire Description WWW PRECILUM C...

Page 12: ...4 CONNECTION DIAGRAMS INGROUND LINEAR INSTRUCTIONS MANUAL v1 1 11 4 1 DALI option Junction box 230V DALI 5 x 1 5 mm Must be specified by the electrical designer Description Luminaire WWW PRECILUM COM...

Page 13: ...ic isolating covering in order to verify any damage Check that all the seals are in good condition and that they are not dry damaged or split Check the glass or plastic screen for damage and replace i...

Page 14: ...High power OSRAM LEDs 2700K 3000K 4000K 5700K See datasheet 230V 50Hz AC Electronic control gear TRIDONIC INGROUND LINEAR 650 18W current 350mA 27W current 500mA INGROUND LINEAR 950 27W current 350mA...

Page 15: ...T INGROUND LINEAR INSTRUCTIONS MANUAL v1 1 14 Precilum provides a product warranty for a period of five 5 years from date of purchase Please refer www precillum com for all warranty terms and conditio...

Page 16: ...Please check for latest updates and changes on the Precilum website 2021 PRECILUM s r o ALL RIGHT RESERVED All specifications subject to change without notice WWW PRECILUM COM...

Reviews: