. Error Code

Err01

Err02

Err03

Out of measuring range

Measuring in a proper range

Reflected signal is too weak

Pythagorean calculation error

Low Battery

Out of working temperature

Ambient light is too strong

Check and verify values and

steps are correct

Install a new battery

Measure in an  environment

within specified working

temperature

Measure in a darker place 

(shadow target)

Select a better surface

Out of display range (Max Value: 

99999), e.g: result of area or 

dimension is out of display range.

Divide caculation into 

intermediate steps

Err04

Err05

Err06

Err07

Code

Description

Solution

. Service Support

Please contact your local dealer or contact us through servise email : 
[ [email protected] ] for further assistance.

Summary of Contents for CX80

Page 1: ...LASER DISTANCE METER CX80 Operation Manual NEW BENCHMARK OF MEASURING www precaster com tw CX80 Operation Manual...

Page 2: ...continuous output of the beams never exceeds 1 0 milli watts 6 Product complies with EMC Test according to EN61000 6 3 2001 A11 2004 EN61000 6 1 2001 EN61326 1 2013 IEC 61326 2012 and FCC Test accordi...

Page 3: ...indow Laser Receiving Window Clear Power Overview for Screen 1 Laser Indicator 2 Indirect Measuring 3 Measuring Function 4 Measuring Reference 5 Add and Subtract 6 Maxmum Display 7 Minimum Display 8 S...

Page 4: ...k again to leave the continuously measurement mode Battery Installation Power Status 1 This unit is powered by 2 x AAA Batteries 2 Remove battery lid and observing correct polarity before install batt...

Page 5: ...LENGTH 4 After finish all the instructions the result AREA will be showed on screen Measurement Reference 1 There are four reference positions for measurement They are back of the unit front of the u...

Page 6: ...GHT will be showed on screen 4 Stack Out Measurement Stack out measurement help users to split a long distance into several piece equally The function need to be used in Continuous Measurement Mode wi...

Page 7: ...ed measurements press and hold to enter the lookup mode 3 Press to move the index up and Press to move index down 4 To clear all stored measurements press and hold again in lookup mode to clear all me...

Page 8: ...rong Check and verify values and steps are correct Install a new battery Measure in an environment within specified working temperature Measure in a darker place shadow target Select a better surface...

Reviews: