Precaster CA109 Specification & Instruction Book Download Page 5

 

CA109 Manual 

Ver. 180212 

 

 

Model 

CA109A 

CA109B 

CA109C 

Single measuring range* 

0.05m~30m 

0.05m~50m 

0.05m~70m 

Continuous measuring range* 

0.05m~30m 

0.05m~50m 

0.05m~70m 

Measuring Frequency** 

0.5~1 second for each measure 

Typical Accuracy* 

±2mm 

Accuracy With CA6**** 

±1mm 

Power 

9V~28V ±0.2V (DC Jack) 

Warm-up Time 

<5 seconds 

Laser output power 

0.6mW~0.95mW 

Operation Temperature 

-5

~40

 

Storage Temperature 

-20

~60

 

Output Interface*** 

RS-232 

RS-485 

* Applies for well reflectivity target (e.g: Kodak white board), low background illumination, 25°C, 
with a low reflectivity target, could decrease measuring range and increased errors which may 
defer by target and environment situation, tolerances apply from 0.05 m to 10 m with a 
confidence level of 95%. The maximum tolerance may deteriorate to 0.25 mm/m after 10 
meters. 
** Measuring range, accuracy is deeply related with measuring speed. A higher measuring 
frequency will series effect range and accuracy, please do contact with our reps for more 
discussion. 
*** Need to be decided prior order. 
**** Work with target CA6 target plate, under favorable condition, tolerances apply from 0.05 m 
to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m 
after 10 meters 

 
 
 
 
 
 
 
 

4. PROTOCOL & DATA FORMAT

 

 

I. 

Protocal :: 

RS232

9600bps 

II.  UART Interface 

 

 

RS-232

 

Reviews: