11
4.5.
Every 6 months:
Change the oil. For this purpose, remove the oil dipstick, remove the oil drain plug beneath
the compressor and allow the oil to drain into a container.
Only perform an oil change when the compressor is warm as this ensures that it is drained
quickly and completely. Re--install the oil drain plug and fill in oil up to the maximum level.
The oil quantity required is 0.36 litres.
Oil is an environmental pollutant. Contact the responsible authorities
regarding disposal.
Clean all ribbed parts of the compressor. This ensures good performance of the cooling sys-
tem and lengthens the service life of the machine.
4.6.
Every 2 years:
Check the valves and replace as necessary.
Clean or replace the sinter filter in the separator
4.7.
Maintenance schedule
Maintenance work
Weekly
Monthly
Every
6 months
Every
2 years
Oil level check
X
Drain condensation
water
X
Clean intake filter
X
Oil change
X
Clean compressor
X
500--hour maintenance by qualified personnel:
Check/
replace valves
X
Clean/
replace sinter filter
X
Summary of Contents for PKT-fillmaster 350
Page 15: ...15 1 2 1 2 4 5 1 2 3 4 5 7 6 8 7 6 3...
Page 16: ...PREBENA Kompressor PKT fillmaster 350 16 3 1 2 3 4 4 min max 5 5 4 3 2 1 6...
Page 33: ...15 1 2 1 2 4 5 1 2 3 4 5 7 6 8 7 6 3...
Page 34: ...PREBENA compressor PKT fillmaster 350 16 3 1 2 3 4 4 Min Max 5 5 4 3 2 1 6...
Page 51: ...15 1 2 1 2 4 5 1 2 3 4 5 7 6 8 7 6 3...
Page 52: ...Compresseur PREBENA PKT fillmaster 350 16 3 1 2 3 4 4 mini maxi 5 5 4 3 2 1 6...
Page 69: ...15 1 2 1 2 4 5 1 2 3 4 5 7 6 8 7 6 3...
Page 70: ...Compresor PREBENA PKT fillmaster 350 16 3 1 2 3 4 4 m n m x 5 5 4 3 2 1 6...