Electrical Specifications
Frequency Range:
2.4-2.4835 GHz
All t-meter models
5.15-5.35 GHz
5.47-5.5975 GHz
5.5975-5.725 GHz
5.725-5.85
GHz
PM-900
902-926
MHz
PM-3500 3.4-3.7
GHz
PM-4900 4.94-4.99
GHz
Forward Power Measurement Range:
0 dBm to 20 dBm (no inline attenuation)
10 dBm to 30 dBm (10 dB inline attenuator)
20 dBm to 40 dBm (20 dB inline attenuator)
30 dBm to 50 dBm (30 dB inline attenuator)
Reflected Power Measurement Range:
-20 dBm to 17 dBm (no inline attenuation)
-10 dBm to 27 dBm (10 dB inline attenuator)
0 dBm to 37 dBm (20 dB inline attenuator)
10 dBm to 47 dBm (30 dB inline attenuator)
Power Measurement Accuracy: +/- 0.5 dBm (with a 1.2:1 LOAD)
Insertion Loss:
0.4 dB @ 2.4 GHz
All t-meter models
0.6 dB @ 5.3 GHz
0.6 dB @ 5.5 GHz
0.6 dB @ 5.6 GHz
0.7 dB @ 5.8 GHz
PM-900
0.2 dB @ 900 MHz
PM-3500
0.5 dB @ 3.5 GHz
PM-4900
0.6 dB @ 4.9 GHz
VSWR Measurement Range: 1.2:1 to 6.0:1 (all bands)
BROADBAND WIRELESS POWER METER
Page 11
Summary of Contents for t-meter
Page 1: ...Broadband Wireless Power Meter User s Manual ...
Page 9: ...Page 6 P R A X S Y M ...
Page 11: ...Page 8 P R A X S Y M ...
Page 13: ...Page 10 P R A X S Y M ...
Page 18: ...BROADBAND WIRELESS POWER METER Page 15 Notes ...
Page 19: ...Page 16 P R A X S Y M Notes ...