background image

 

 

INVERTER GENERATOR – P2000i 

 

SAFETY INFORMATION 

 

FUEL IS HIGHLY FLAMMABLE AND POISONOUS 

  Always turn off the engine when refueling. 

  Never refuel while smoking or in the vicinity of an open flame. 

  Take care not to spill any fuel on the engine or muffler when refueling. 

  If you swallow any fuel, inhale fuel vapor, or allow 

  Any to get in your eye(s), see your doctor immediately. If any fuel spills 

on  your  skin  or  clothing,  immediately  wash  with  soap  and  water  and 

change your clothes. 

  When operating or transporting the machine, be sure it is kept upright. If 

it tilts, fuel may leak from the carburetor or fuel tank. 

 

EXHAUST FUMES ARE POISONOUS 

  Never  operate  the  engine  in  a  closed  area  or  it  may  cause 

unconsciousness and death within a short time. Operate the engine in a 

well ventilated area. 

 

 

ENGINE AND MUFFLER MAY BE HOT 

 

  Place the machine in a place where pedestrians or children are not likely 

to touch the machine. 

 

 

  Avoid  placing  any  flammable  materials  near  the  exhaust  outlet  during 

operation. 

 

 

 

 

 

Summary of Contents for P2000i

Page 1: ...INVERTER GENERATOR P2000i Operating Manual ...

Page 2: ... concern Therefore please take the time to read the entire manual especially the Safety Precautions They will help you to avoid potential hazards that may exist when working with this product WARNING READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY PROPERTY DAMAGE ANDIOR VOIDING OF YOUR WAR...

Page 3: ...Capacity 24 4 2 Power Management 24 4 3 Connecting Electrical Loads 24 4 4 Parellel Connection within 2 generator 25 4 5 Battery Charging 28 4 6 Wattage Reference Guide 29 5 MAINTENANCE 31 5 1 Periodic Maintenance 31 5 2 Spark Plug Maintenance 32 5 3 Engine Oil Replacement 33 5 4 Air Filter Maintenance 34 5 5 Muffler Screen and Spark Arrestor Maintenance 35 5 6 Fuel Filter Maintenance 36 6 STORAGE...

Page 4: ...AND WARNINGS WARNING THE ENGINE EXHAUST FROM THIS PRODUCT CONTAINS CHEMICALS TO CAUSE CANCER BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM NOTE Read this manual carefully before operating this machine This manual should stay with this machine if it is sold ...

Page 5: ...correct operation of your PRAMAC product Your satisfaction with this product and its safe operation is our ultimate concern Therefore please take the time to read the entire manual especially the Safety Precautions They will help you to avoid potential hazards that may exist when working with this product ...

Page 6: ...NSTRUCTIONS ARE NOT FOLLOWED NOTICE CAUTIONS INDICATE A POSSIBILITY ARE NOT FOLLOWED PROPERLY TIPS TIPS GIVE HELPFUL INFORMATION WARNING PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE MACHINE TIP Continually seeks advancements in product design and quality Therefore wherein this manual contains the most current product information available at the time of printing there may...

Page 7: ...our skin or clothing immediately wash with soap and water and change your clothes When operating or transporting the machine be sure it is kept upright If it tilts fuel may leak from the carburetor or fuel tank EXHAUST FUMES ARE POISONOUS Never operate the engine in a closed area or it may cause unconsciousness and death within a short time Operate the engine in a well ventilated area ENGINE AND M...

Page 8: ... or other objects covering it When covering the generator be sure to do so only after the engine and muffler have completely cooled down Be sure to carry the generator only by its carrying handles Do not place any obstacles on the generator ELECTRIC SHOCK PREVENTION Never operate the engine in rain or snow Never touch the machine with wet hands or electrical shock will occur ...

Page 9: ... main fuse box The switch is the connection point for generator power and allows selection of generator or main line power to the building This will prevent the generator from charging the main power line back feeding when the main power supply has failed or has been turned off for line repair Back feeding can electrocute or injure line maintenance personnel Also generator and building electrical ...

Page 10: ...INVERTER GENERATOR P2000i 10 LOCATION OF IMPORTANT LABELS Please read the following labels carefully before operating this machine TIP Maintain or replace safety and instruction labels as necessary 1 ...

Page 11: ...INVERTER GENERATOR P2000i 11 2 3 ...

Page 12: ...NVERTER GENERATOR P2000i 12 2 CONTROLS AND FEATURES 2 1 Generator 1 Muffler 2 Carrying handle 3 Vented Gas Cap 4 Recoil Starter 5 Control Panel 6 Fuel Gauge 7 Exhaust and Spark Arrestor 8 Oil filter cap ...

Page 13: ...ilot Light 4 Overload Indicator Light 5 Oil Warning Light 6 12V DC Output 7 8A DC Circuit Breaker 8 Fuel Petcock 9 Choke 10 220 230 240V AC Outlets This socket is only corresponding to a client the different laws and regulations according to the sales area changes corresponding to the socket 11 Ground Terminal ...

Page 14: ...nt such as a compressor pump or refrigenator Led Indicators The LED Indicators assist in communicating proper and improper functions of the unit Output Indicator Green The Output Indicator comes on when the engine starts and produces power Overload Alarm Red The Overload Alarm comes on when a connected device requires more power than the generator is able to produce the inverter control unit overh...

Page 15: ...the required level the Low Oil Alarm will come on and the engine will stop automatically The engine will not restart untiloil is added to the unit to bring it up to the appropriate level NOTE When starting the unit if the Low Oil Alarm light flickers and the engine will not start you will need to add engine oil before attempting to restart the engine NOTE Generator should only be operated on a lev...

Page 16: ... should be in the I position when starting and operating the generator The Petcock knob should be in the O position when the engine is not running and when storing or transporting the unit NOTE The Fuel Petcock knob helps to prevent stale fuel from remaining in the carburetor while storing or transporting the unit Run the fuel out by turning the knob to the O position and letting the engine run un...

Page 17: ...0W continuous power This socket is only corresponding to a client the different laws and regulations according to the sales area changes corresponding to the socket Ground Terminal The Ground Earth terminal is used to ground the generator when grounded electrical devices are being used Consult an electrician for local grounding regulations ...

Page 18: ...ars to be damaged DO NOT add fuel or attempt to start the generator Please call PRAMAC costumer service Check to ensure that you received the following items P 2000i 2000W Generator Parallel Cables Oil Funnel If you did not receive any of the above items please contact PRAMAC costumer service 3 2 Adding engine Oil The generator has been shipped without engine oil DO NOT add fuel or start the engin...

Page 19: ...e adding oil It can cause you to overfill the oil and or cause the oil to leak into areas in which it is not intended Remove the oil filler cap 1 seen in figure 2 Figure 3 Using the funnel provided fill with 0 4 L of SAE 10W 30 or 10W 40 provided see figure 3 See figure 4 for proper oil level 1 Figure 4 Replace oil filler cap and secure side panel with screws Recommended engine oil A YAMALUBE4 10W...

Page 20: ...o the place of purchase 1 Use clean fresh regular unleaded fuel with a minimum octane rating of 85 2 DO NOT mix oil with fuel 3 Clean area around the fuel cap 4 Remove the fuel cap 5 Be sure that the fuel strainer is in place 6 Slowly add fuel to the tank 7 Do not exceed the red marker position of the fuel filter 8 Screw on the fuel cap and wipe away and spilled fuel NOTE Use only unleaded gasolin...

Page 21: ...the generator before starting the engine 1 Turn the Economy Throttle switch O You may turn the Economy Throttle switch to I once the engine is started and a s teady idle is achieved below 0 32 F 5mins below 5 C 41 F 3mins 2 While holding the fuel tank cap so that it will not move turn the air vent knob to ON 3 Turn the Fuel Petcock knob to the I position ...

Page 22: ... original position when starting the engine warm 6 Grasp the carrying handle firmly to prevent the generator from falling over when pulling the recoil starter 7 Pull slowly on the recoil starter until it is engaged and then pull it briskly 8 After the engine starts warm up the engine until the engine does not stop when the choke knob is returned the original position ...

Page 23: ...OR P2000i 23 3 5 Stopping the Engine Before stopping the engine turn off and disconnect any electronic devices attached to the generator Turn the Throttle switch O Turn the Engine switch to O Turn the Fuel Petcock to O ...

Page 24: ...riven equipment Following the steps listed under Power Management will guarantee that only one device will be starting at a time 4 2 Power Management Use the following formula to convert voltage and amperage to watts Volts x Amps Watts To prolong the life of your generator and attached devices follow these steps to add electrical load 1 Start the generator with no electrical load attached 2 Allow ...

Page 25: ...s of 220 230 volt AC powered tools and equipment into the 220 230 volt AC dual outlets and or the power cord of a 12V DC powered tool to the DC terminals 4 DO NOT connect 3 phase loads to the generator 5 DO NOT connect 60Hz loads to the generator 6 DO NOT overload the generator NOTE The DC terminals may be used for charging 12 volt type batteries only 4 4 Parellel Connection within 2 generator Per...

Page 26: ...RATOR P2000i 26 2 Put the parallel connection wire 1 and 2 into the parallel connection sockets 3 and 4 Attention Grounding Wire must be properly installed and worked if needed Keep each inverter generator in steady ...

Page 27: ...ly use P2000i specialized parallel connecting wire When use parallel connecting way for P2000i inverter generators put the plug into sockets safety Make use put the right plug into sockets for parallel connecting wire When working on parallel connecting way don t put off the parallel connecting wire Before starting parallel connecting wire need to be connected firstly Only put off the wire after i...

Page 28: ...rminal DO NOT reverse these positions 3 Connect the battery charger leads to the battery terminals securely so that they are not disconnected due do engine vibration or other disturbances 4 Charge the battery by following the instructions in the owner s manual for the battery 5 The DC Circuit Breaker will turn O automatically if the current exceeds rated output 6 To restart charging the battery tu...

Page 29: ...ating and Cooling Air Conditioner 12000 BTU 1700 2500 Fan 300 600 Furnace Fan 1 3 Hp 1200 2000 Home Appliances Microwave 1000 Electric Range One Element 1500 Electric Skillet 1250 Coffee Maker 1500 Clothes Washer 1200 Entertainment CD DVD Player 100 Stereo Receiver 450 Television 27 500 PC with 15 Monitor 800 Job Site Belt Sander 3 1000 1500 Bench Grinder 6 700 1500 Circular Saw 1500 1500 Compress...

Page 30: ... generator Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging to plugging them into this generator Damage may result if the equipment is not designed to operate within a 10 voltage variation and 3 Hz frequency variation from the generator specification ratings Your Power Needs Tool or Appliance Running Watts Starting Watts 1 2 3 4 5 Total Ru...

Page 31: ...n Clean and replace if necessary Fuel Check fuel level and leakage Fuel hose Check fuel hose for cracks or damage Replace if necessary Engine oil Check oil level in engine Replace Air Filter Element Check condition Clean Muffler Screen Check Condition Clean or replace if necessary Spark Arrestor Check Condition Clean or replace if necessary Fuel Filter Check Condition Clean or replace if necessary...

Page 32: ...he handlebar 6 into the tool 5 and turn it counterclockwise to remove the spark plug 5 Check for discoloration The carbon porcelain insulator around the center electrode of spark plug should be a Medium to light tan color 6 Check the spark plug type and gap The spark plug gap should be measured with a wire thickness gauge and if necessary adjusted to specification Spark Plug Type BPR6HS NGK Spark ...

Page 33: ...cover 2 3 Remove the oil filler cap 4 Place an oil pan under the engine Tilt the generator to drain the oil completely 5 Return the generator to a level surface NOTE DO NOT tilt the generator when adding engine oil This could result in overfilling and damage to the engine 6 Add engine oil to the upper level as seen in the diagram 1 Recommended engine oil YAMALUBE 4 10W 40 SAE 10W 30 or MOW 40 SAE ...

Page 34: ... cover 2 3 Remove the foam element 4 Wash the foam element in solvent and dry it 5 Oil the foam element and squeeze out excess oil The foam element should be wet but not dripping NOTE Do not wring out the foam element when squeezing it This could cause it to tear 6 Insert the foam element into the air filter case Be sure the foam element sealing surface matches the air filter so there is no air le...

Page 35: ...hen remove the cover 2 2 Loosen the bolt 1 and the remove the muffler cap 2 the muffler screen 3 and spark arrester 4 3 Remove the carbon deposits on the muffler screen and spark arrester using a wire brush Use wire brush lightly to avoid damaging the muffler screen or spark arrestor 4 Check the muffler screen and spark arrester replace them if damaged 5 Install the spark arrester 6 Install the mu...

Page 36: ...ry 12 months or 300 hours 1 Remove the fuel tank cap and filter 1 2 Clean the filter with gasoline 3 If damaged replace it 4 Wipe the filter and install it 5 Install the fuel tank cap WARNING GASOLINE IS FLAMMABLE DO NOT perform this maintenance while smoking or near an open flame ...

Page 37: ...y available hand siphon Then install the fuel tank cap WARNING GASOLINE IS FLAMMABLE DO NOT perform this maintenance while smoking or near an open flame WARNING Immediately wipe off spilled fuel with a clean dry soft cloth since fuel may deteriorate painted surfaces or plastic parts 3 Turn the Engine switch to I 4 Turn the fuel tank cap air vent knob to ON and Fuel Petcock knob to I 1 5 Start the ...

Page 38: ...llowing steps to protect the cylinder piston ring etc from corrosion 1 Remove the spark plug pour about one table spoon of SAE 10W 30 or 20W 40 motor oil into the spark plug hole and reinstall the speak plug Recoil start the engine by turning over several times with ignition off to coat the cylinder walls with oil 2 Pull the recoil starter until you feel compression Then stop pulling this prevents...

Page 39: ...OK Consult a dealer G Level low Add engine oil H Pull the recoil starter and check the spark plug for spark strength See WARNING WARNING To Prevent FIRE HAZARDS be sure fuel is not present in the spark plug area To prevent FIRE HAZARDS be sure to place the spark plug as far way as possible from ste spark plug hole and carburetor area To prevent ELECTRIC SHOCK do not hold spark plug lead with hand ...

Page 40: ... t start Fuel systems No fuel supplied to combustion chamber No fuel in tank supply fuel Fuel in tank Fuel tank cap air vent knob to ON and fuel cock knob to I Clogged fuel line clean fuel line Clogged carburetor clean carburetor Engine oil system insufficient Oil level is low add engine oil Electrical systems Engine switch to I and pull the recoil starter Poor spark Spark plug dirty with carbon o...

Page 41: ...9cc Running Watts 1600w Starting Watts 2000w Rated Frequency 50Hz Rated Voltage 230V Rated Current 7A Run Time 10 5hrsat1 4load Receptacles qty 1 230V AC 1 12V 8A DC Net Weight 21 KG Noise Level dB 51dB 1 4 Load Fuel Type Unleaded gasoline Fuel Capacity liters 4 3 Oil Type SAE10W 40 Start Type Recoil Dimensions L x W x H in 530x315x490mm ...