background image

 

 

SECTION 1   

 

GENERAL INFORMATION 

 
This manual is provided for you so that your 
generator may be properly, safely and effectively 
applied and operated. Please read and understand 
all aspects of this manual before operating your 
generator set. Please also read and understand the 
documentation supplied with this generator 
regarding the engine. Keep this documentation in a 
safe and accessible place so that reference can be 
made as needed. All operators, users and 
subsequent owners of this generator must read and 
understand all aspects of this documentation before 
operation.  
 

SPARK ARRESTING MUFFLER 

Certain States and Jurisdictions require that engine 
driven equipment be fitted with spark arresting mufflers. 
Depending on the generator model, spark arresting 
mufflers may or may not be fitted. If spark arresting 
mufflers are required for your specific local and the 
generator muffler is not spark arresting, contact your 
local dealer for instructions for a retrofit. 

 

EXHAUST EMISSION CONTROL SYSTEM  

The exhaust emission control system for this generator 
complies to the standards set forth by the California Air 
Resources Board (CARB) and the Environmental 
Protection Agency (EPA). Warranties for the exhaust 
emission system are administered by the respective 
engine manufacturers. Refer to the engine 
documentation for warranty information. 

 

WARNING 

California Proposition 65 

The engine exhaust from this product contains 
chemicals known to the State of California to cause 
cancer, birth defects, or other reproductive harm. 

 

THIS SYMBOL IS USED THROUGHOUT YOUR 
OWNER

S MANUAL TO BRING ATTENTION TO 

IMPORTANT SAFETY INSTRUCTIONS. FAILURE TO 

FOLLOW SAFETY INSTRUCTIONS COULD ENDANGER YOU 
OR OTHERS AND RESULT IN PERSONAL INJURY OR 
DEATH. READ AND UNDERSTAND ALL SAFETY 
INSTRUCTIONS BEFORE OPERATION. 

 

DO NOT OPERATE THIS GENERATOR WITHIN AN 
ENCLOSED AREA. THE EXHAUST GASES OF THIS 
GENERATOR EMIT 

DEADLY

 CARBON 

MONOXIDE. EXPOSURE TO CARBON MONOXIDE CAN 
CAUSE CARBON MONOXIDE POISONING, HEADACHES, 
NAUSEA, SEVERE SICKNESS OR DEATH. 

 

DANGER: THIS GENERATOR SET PRODUCES 
ELECTRICAL CURRENT. THEREFORE, SAFETY 
GUIDELINES MUST BE FOLLOWED. IMPROPER 

USE OF THIS GENERATOR CAN RESULT IN 
ELECTROCUTION, INJURY OR DEATH. DO NOT OPERATE, 

SERVICE OR REPAIR THIS GENERATOR UNLESS FULLY 
QUALIFIED TO DO SO. 

DANGER:  DO NOT OPERATE THIS GENERATOR 
IF THE AMBIENT TEMPATURE EXCEEDS 
105ºF/41ºC. 

 
 

SAFETY RULES 

 

DANGER

: This generator set is designed to be 

operated in dry conditions and for outdoor areas 
only. Never operate this generator indoors. 

Never operate this generator in rain, snow, sleet or 
generally wet conditions. Damage to the generator, bodily 
injury, or death could result from electrocution. 

 

DANGER:

 If this generator is connected to a 

building, home, business, or any other electrical 
circuit normally fed by utility power, steps must 

be taken to insure the generator output and the utility 
power are positively isolated. Failure to isolate the utility 
and generator electrical systems will result in generator 
damage and could result in injury or death to utility 
workers due to the backfeed of electricity. 

 

CAUTION

:  Do not exceed the rated capacity of 

the generator. The total electrical loads at each 
outlet must be added to determine the total 

electrical load. The total load must not exceed the rated 
capacity of the generator. If the driven apparatus does not 
list wattage, but only amperage, wattage may be 
determined by multiplying amperage times voltage (watts 
= amps X volts). 

 

CAUTION:

 Do not tamper with the engine-

governed speed. The generator operates at a 
nominal speed of 3600 rpm. Increases in speed 

over the 3600 rpm nominal will increase the chance of 
personal injury due to rotational stresses on the rotating 
members. Operation of the generator at speeds below the 
nominal 3600 rpm could cause damage to the generator 
or driven apparatus due to low voltage output. 

 

CAUTION:

 Do not modify or misapply your 

generator set. Operation of the generator other 
than intended, could result in generator set 

damage, bodily injury or even death from electrocution. 

 
 

 
 

 

Summary of Contents for E3100

Page 1: ...s provided below Retain these numbers for future reference The Model and Serial numbers are located on the generator data plate on the alternator case or generator frame along with other important information Model Number Serial Number Model Numbers E3100 E3600 E4500 E5000 E SERIES GENERATOR USER MANUAL Power Systems ...

Page 2: ...rized Agent transportation costs to be born by Buyer the goods or components and if goods are proven to be other than as warranted replacement or repaired components will be shipped cheapest way to the Buyer with transportation costs borne by the Seller PRAMAC Industries Inc reserves absolute and final decision power regarding the warrantability of any and all failed components or parts Some state...

Page 3: ...RFORMANCE GUIDELINES 6 RECEPTACLE DETAILS 7 ENGINE LIMITATIONS ON GENERATOR PERFORMANCE 7 LOADING YOUR GENERATOR SET 7 AMPERAGE RATE TABLE 8 SECTION 2 9 E3100 AND E3600 GENERATOR PARTS AND PART LISTS 9 A C Wiring Schematic 11 SECTION 3 12 E4500 AND E5000 GENERATOR PARTS AND PART LISTS 12 A C Wiring Schematic 14 All information provided in this manual is believed to be correct at the time of printi...

Page 4: ...POSURE TO CARBON MONOXIDE CAN CAUSE CARBON MONOXIDE POISONING HEADACHES NAUSEA SEVERE SICKNESS OR DEATH DANGER THIS GENERATOR SET PRODUCES ELECTRICAL CURRENT THEREFORE SAFETY GUIDELINES MUST BE FOLLOWED IMPROPER USE OF THIS GENERATOR CAN RESULT IN ELECTROCUTION INJURY OR DEATH DO NOT OPERATE SERVICE OR REPAIR THIS GENERATOR UNLESS FULLY QUALIFIED TO DO SO DANGER DO NOT OPERATE THIS GENERATOR IF TH...

Page 5: ...THE GENERATOR WHILE IT IS RUNNING Spillage onto the engine or generator could result in an explosion or fire Always allow the generator set to cool before refilling Do not store this generator set in any location where gasoline fumes could potentially come into contact with sparks a pilot light or an open flame Improper storage of this generator could result in an explosion or fire GROUNDING The N...

Page 6: ...ENERATOR CORRECTED TO THE ACTUAL ENVIRONMENTAL CONDITIONS AT THE OPERATING SITE As a reference only Table 1 below shows some general wattage requirements for several common electrical devices This chart is intended as a guide only The actual total wattage should be determined by referring to the actual labels on each of the powered electrical devices Table 1 GENERAL WATTAGE GUIDE Item Running Watt...

Page 7: ...eration of your generator at temperatures above 60 F 20C or above Sea Level will result in lower electrical output Electrical output must be derated 2 for each 9 F above 60 F and 3 for each 1000 feet above mean sea level LOADING YOUR GENERATOR SET With reference to the Receptacle details section please review the power receptacles fitted to your generator The actual load that may be pulled from ea...

Page 8: ... ONLY NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS A...

Page 9: ...9 SECTION 2 E3100 AND E3600 GENERATOR PARTS AND PART LISTS Frame and Parts list for E3100 E3600 ...

Page 10: ...10 ...

Page 11: ...11 A C WIRING SCHEMATIC Model CB Rating AWG Rating E3600 15A 12AWG E4500 20A 12AWG E5000 20A 12AWG ...

Page 12: ...12 SECTION 3 E4500 AND E5000 GENERATOR PARTS AND PART LISTS Frame and Parts list for E4500 E5000 ...

Page 13: ...13 ...

Page 14: ...14 A C WIRING SCHEMATIC Model CB Rating AWG Rating E3600 15A 12AWG E4500 20A 12AWG E5000 20A 12AWG ...

Page 15: ...15 Notes ...

Reviews: