5. Cycle sequence: Starting position "filter" - equipment ON
- Start of the back rinsing cycle
- Control light "test key" for back rinsing cycle running, lights up
- Output heating COM-NO switches to Com-NC control.
- Adjusted time of potentiometer (deceleration time) runs off (cooling time for heat exchanger).
- Output pump COM-NO switches off
- Output serial connection switches from COM-NC to Com-NO
- Output ball valve switches from COM-NO to COM-NC
- Valve on back rinse
- Output back rinse/clear rinse COM-NC switches to COM-NO
- Pump deceleration time of approx. 20 seconds runs
- Output pump COM-NO closes
- Output back rinse COM-NC switches to COM-NO
- Adjusted time of potentiometer runs (back rinsing time)
- Output pump COM-NO switches off
- Output back rinses switches from COM-NO to COM-NC
- Output back rinse, clear rinse switches from COM-NO to COM-NC
- Valve on clear rinse
- Output back rinse/clear rinse switches from COM-NC to COM-NO
- pump deceleration time of approx. 20 seconds runs
- Output pump COM-NO closes
- Adjusted time of potentiometer runs (clear rinse)
- Output pump COM-NO switches off
- Output back rinse/clear rinse switches from COM-NO to COM-NC
- Valve on filter
- Output serial connection COM-NO switches to COM-NC
- Output ball valve switches from COM-NC to COM NC
- Pump deceleration time of approx. 20 seconds runs
- Output pump COM-NO closes
- Output heating switches from COM-NC to COM-NO
7
5
6
Transpose
Filter - back rinse
Back rinse
Transpose
Back rinse - clear rinse
Clear rinse
Transpose
Clear rinse - filters
Cycle period
approx. 45 sec.
25 sec. - 11 min.
approx. 35 sec.
20 sec. - 3 min.
approx. 25 sec.
Rinsing times and changing over time:
Deceleration time
25 sec. - 23 min.
approx. 3 - 40 min.
PRECISION - POWER - PROGRESS - PRODUCTION
Operating instructions
SUPERSTAR E-3000 / F2
for 1 1/2", 2"and 3" 24 VAC