praher SUPERSTAR E-3000/F2 Operating Instructions Manual Download Page 4

Page 4

5. Cycle sequence:  Starting position "filter" - equipment ON

- Start of the back rinsing cycle
- Control light "test key" for back rinsing cycle running, lights up
- Output heating COM-NO switches to Com-NC control.
- Adjusted time of potentiometer     (deceleration time) runs off (cooling time for heat exchanger).
- Output pump COM-NO switches off
- Output serial connection switches from COM-NC to Com-NO 
- Output ball valve switches from COM-NO to COM-NC
- Valve on back rinse
- Output back rinse/clear rinse COM-NC switches to COM-NO 
- Pump deceleration time of approx. 20 seconds runs
- Output pump COM-NO closes
- Output back rinse COM-NC switches to COM-NO
- Adjusted time of potentiometer     runs (back rinsing time)
- Output pump COM-NO switches off
- Output back rinses switches from COM-NO to COM-NC
- Output back rinse, clear rinse switches from COM-NO to COM-NC
- Valve on clear rinse
- Output back rinse/clear rinse switches from COM-NC to COM-NO
- pump deceleration time of approx.  20 seconds runs
- Output pump COM-NO closes
- Adjusted time of potentiometer      runs (clear rinse)
- Output pump COM-NO switches off
- Output back rinse/clear rinse switches from COM-NO to COM-NC
- Valve on filter
- Output serial connection COM-NO switches to COM-NC
- Output ball valve switches from COM-NC to COM NC
- Pump deceleration time of approx. 20 seconds runs
- Output pump COM-NO closes
- Output heating switches from COM-NC to COM-NO

7

5

6

Transpose
Filter - back rinse

Back rinse

                     

Transpose

Back rinse - clear rinse

Clear rinse

Transpose

Clear rinse - filters

Cycle period

 

approx. 45 sec.

25 sec. - 11 min.

approx. 35 sec.

20 sec.  - 3 min.  

approx. 25 sec.

Rinsing times and changing over time:

Deceleration time

25 sec. - 23 min.

approx.  3 - 40 min.

PRECISION - POWER - PROGRESS - PRODUCTION

Operating instructions

SUPERSTAR   E-3000 / F2

for 1 1/2", 2"and 3" 24 VAC

 

Summary of Contents for SUPERSTAR E-3000/F2

Page 1: ...n time Electr Connection Board for E 3000 F2 24V Exploded view G F E D A C H B L K I M Operating instructions SUPERSTAR E 3000 F2 for 1 1 2 2 and 3 24 VAC Table of contents Ensuing damage due to neglect of the operating instructions or due to damaging sealed parts lead to a lapse of the warranty We do not take on liability for thus resulting damages Please read the operating instructions carefully...

Page 2: ...tely if it has been taken from a cold into a warm area The thereby developing condensation water could destroy your equipment If the equipment has visible damages doesn t work anymore or has been stored for longer periods under adverse conditions then it is to be expected that a safe operation is not possible anymore In this case the equipment is to be secured against unintentional start up and if...

Page 3: ...ng according to the inscription and the following sketch Use transition screw connections Seal threaded connections only with teflon band The equipment is functional in any position however if possible should not be installed with the actuator downwards Pump Basin Drain To the Filter From the Filter PUMP from the pump to the filter BOTTOM from the Filter Return to the basin Waste to the Drain TOP ...

Page 4: ...k rinse clear rinse switches from COM NO to COM NC Valve on clear rinse Output back rinse clear rinse switches from COM NC to COM NO pump deceleration time of approx 20 seconds runs Output pump COM NO closes Adjusted time of potentiometer runs clear rinse Output pump COM NO switches off Output back rinse clear rinse switches from COM NO to COM NC Valve on filter Output serial connection COM NO swi...

Page 5: ...ss key clock keep key pressed and with Day key select desired day clock keep key pressed and with h key select desired hour clock keep key pressed and with m key select desired minute 8 Program back rinsing time Prog press key Manual key press ON on display appears ON Time programmming with Day key select day E with h key select hour with m key select minute with Manual key programming time can be...

Page 6: ...lockwise direction for a lengthy period against clockwise direction short period trigging a back rinsing procedure with the test key checking the clear rinsing time repeat the sequence until the desired time is adjusted 10 2 Adjusting the deceleration time The deceleration time can be stopped with the potentiometer rotary button turn the potentiometer clockwisedirection clockwisedirection against ...

Page 7: ...cted through during entire back rinsing cycle and position emptying e Connection for 2 Back rinsing pump Zero potential I max 4 A In position back rinse 28 27 is connected through Switches only if pump is 13 14 switched on f Connection for signal on position back rinse and clear rinse Zero potential I max 4 A 25 24 connected through in position back rinse and clear rinse Switches independently of ...

Page 8: ...ycle EXTERNAL Floating Connection possibilities SPS push button switch push button switch cycle strarts about 40 50 seconds later to compensate pressure peaks j Trigger cycle EXTERNAL Zero potential Note trigger only short pulse SPS Pressure switch NO COM NC NO COM NC 21 22 23 18 19 20 G 18 20 CH2 CH1 19 20 19 18 Valve 3 G CH2 CH1 Valve 2 20 19 18 Valve 1 Serial connection for several valves Techn...

Page 9: ...72E Analog S14K35 14 28 OFF Day CH2 CH1 CH1 MO CH1 Clock Uhr pot frei Output Kugelhahn Ausgang Kugelhahn Ballvalve Relais Pump Output pot frei Pumpe Ausgang 13 14 Pumpe Switch Level Schalter Niveau 9 10 Digital Uhr E Prom S S 5 G L D 1 Versorgungs S G S G S S 5 G L D 1 MotorKondensator 3 1 6A T E Type 24VAC 2 grau 1 braun 3 grün G C3 C2 27 RÜCKSPÜLEN 28 BACKWASH RÜCKSPÜL ZEIT ZEIT KLARSPÜL R 4 29 ...

Page 10: ...OVATION ENTLEEREN DRAIN AUS OFF EIN ON PRÜFTASTE TESTBUTTON SERVICE R R R S U P E R S T A R 1 Cover 2 Seal foam rubber 3 Control switch 4 Curve gear wheel 5 Motor 6 Control board 7 Pump limit switch 8 Automatic lower part 9 Mounted screw connection 10 Clutch 11 Valve 12 Back rinsing clock 13 Film keyboard Operating instructions SUPERSTAR E 3000 F2 for 1 1 2 2 and 3 24 VAC PRAHER VALVES Tel 43 0 72...

Reviews: