29
Relay output:
Frequency max. .......................................... 20 Hz
Vmax. ......................................................... 250 VRMS
Imax. ........................................................... 2 A / AC
Max. AC power .......................................... 500 VA
Max. AC power Ex version 5223B ............. 100 VA
Max. load at 24 VDC .................................. 1 A.
EEx / I.s. approval -5223B:
KEMA 04ATEX1001 .....................................
II (1) GD
[EEx ia] IIC
Applicable in zone ...................................... 0, 1, 2, 20, 21 or 22
Ex / I.s. data:
Terminal 31, 33
Um ..............................................................
:
250 V
Terminal 42, 43 and 52, 53
Uo ...............................................................
:
10.6 VDC
Io .................................................................
:
13.8 mA
Po ............................................................... : 38 mW
Lo ...............................................................
:
160 mH
Co ...............................................................
:
1.9 µF
GOsT R approval:
VNIIM & VNIIFTRI, Cert. no. ........................ See www.prelectronics.com
Observed authority requirements:
standard:
EMC 2004/108/EC ..................................... EN 61326-1
LVD 2006/95/EC ......................................... EN 61010-1
PELV/SELV .................................................. IEC 364-4-41 and EN 60742
ATEX 94/9/EC ............................................. EN 50014, EN 50020 and
EN 50284
Of span
= Of the presently selected range