18
Total reset
200
209
Reserved
210
229
Reserved
240
255
Note:
1.
Fan errors can cause LED lamps to be shut off;
2. "Speed Mode" means Pan and Tilt will move from Point A to Point B at their respective maximum speeds."Time Mode" means
both Pan and Tilt will arrive at designated point at the same time. It's advised Time Mode be used if the projector runs circles or in
oblique lines.
8.
SIGNS ON THE DISPLAY
Lamp Control
Option Settings
Chinese/English
Information
Error Messages
Service
Address
Operation Mode
Reset
User Memories
Config Settings
9.
ERROR MESSAGE
The system can detect some errors during the reset, if
displayed, touch
to view the error.
The error messages are as follows:
Name
Type
Correction
Pan
Timeout/magnet Sensor/Encoder
Check if wiring, positioning parts and motors are normal
Tilt
Timeout/magnet Sensor/Encoder
Check if wiring, positioning parts and motors are normal
Cyan
Timeout
Check if wiring, positioning parts and motors are normal
Yellow
Timeout
Check if wiring, positioning parts and motors are normal
Magenta
Timeout
Check if wiring, positioning parts and motors are normal
CTO
Timeout
Check if wiring, positioning parts and motors are normal
Color wheel
Timeout
Check if wiring, positioning parts and motors are normal
Rotating gobo wheel1
Timeout
Check if wiring, positioning parts and motors are normal
Gobo rotation 1
Timeout
Check if wiring, positioning parts and motors are normal
Rotating gobo wheel2
Timeout
Check if wiring, positioning parts and motors are normal
Gobo rotation 2
Timeout
Check if wiring, positioning parts and motors are normal
Dimmer
Timeout
Check if wiring, positioning parts and motors are normal