![PR Lighting AQUA 580 BEAM Manual Download Page 8](http://html1.mh-extra.com/html/pr-lighting/aqua-580-beam/aqua-580-beam_manual_1593128008.webp)
8
●
ALIGNMENT/INSTALLATION/REPLACEMENT OF A LAMP
Please hold the projector well before adjustment/installation/replacement of lamp. As shown in figure1, remove fan cover of the head
and heat sink.
Removal/Installation of lamp as shown in figure2
Adjust the lamp as shown in figure3
Before the removal of the lamp, unplug the lamp wires. And plug lamp wires after a new one is in.
●
Don’t touch the internal surface of the reflector and the burner of the lamp with bare hands so as not to impair the
beam output. There is a protruding metal wire in the lamp, while installation do not damage it. Hold the lamp body
well before its removal. It’s forbidden to use force on the ceramic stand, otherwise it will loosen or fall off.
●
Please read "Instructions " enclosed with the lamp
●
While adjusting the lamp, it is forbidden to carry out the functions not associated with lamp adjustment.
Figure1: loosen 4 screws of the fan cover of the head before removing it. Then loosen the screws of heat sink and remove it
and the fan.
Figure2: Unplug the lamp wires , push the upper clipping plate toward the spring with force, but push the lamp in the
opposite direction till it is off the plate, then take the lamp out obliquely. The same applies to its installation.
Figure 3: After the replacement of the lamp, please ensure first the lamp is clipped well before plugging lamp wires. Turn the
lamp on and adjust the lamp’s position to the middle. After that, install the heat sink, fan and fan cover.
1.
After the projector is powered on, disable the following function in the menu: services-factory mode- lamp fan sensor , then shut
it from power
2.
Loosen the 4 screws of the fan cover and remove it.
3.
Loosen 4 screws of the fan plate, remove the fan and the clump weight, loosen 10 screws of the heat sink and remove it.
4.
Push the upper clipping plate of the lamp towards the spring, and at the same time pus the lamp towards the opposite till it is off
the plate and remove it obliquely,
5.
The installation of the lamp is the same as its removal
6.
Check if the lamp wires are plugged well, then turn on the lamp for adjustment
7.
After the adjustment of the lamp, activate the following function in the menu: services-factory mode- lamp fan sensor. Then shut
it from the power
8.
Check if the seals are good or not. If not, replace them with good ones. If no, install the heat sink, fan and fan cover in the
opposite sequences as the removal.
9.
After installation, power it on. The projector will execute the total reset. After that, the projector can be used normally.
●
GOBO REPLACEMENT
Summary of Contents for AQUA 580 BEAM
Page 25: ...25...